{"title":"Time-Domain Nonlinear Stability Analysis of Multi-VSC System as Affected by Distribution Feeder Parameters","authors":"Yujun Ding, Hongtao Li, Hua Ye, W. Pei, Jiawang Xiong, Liang Hao","doi":"10.1109/ICPST56889.2023.10165613","DOIUrl":null,"url":null,"abstract":"The rapid development of renewable energy has promoted the development of power electronic devices. A large number of devices represented by voltage source converter (VSC) have been incorporated into the power grid, which has caused a series of stability problems correspondingly. Thus, this paper starts from the distribution feeder parameters and investigates their influence on the stability of the multi-VSC system. In this paper, an improved Kron reduction method is proposed to reduce the order of multi-VSC system equivalently. This method can eliminate unnecessary nodes in any power network which contributes to simplifying later calculation. Then based on the reduced multi-VSC system, the dynamic equation of VSC is established and extended to multi-VSC system. Third, a new system stability criterion is proposed by using the average method. In order to analyze the influence of distribution feeder parameters on multi-VSC system stability, the generalized short circuit ratio calculation formula of the multi-VSC system is introduced. For the real system, the influence of the distribution feeder parameters on the stability of the system can be obtained by finding out the relationship between the new stability criterion proposed in this paper and the generalized short-circuit ratio. The case study has illustrated the effectiveness of the proposed methods. The conclusion of this paper is helpful to study the influence of complex distribution feeder on multi-VSC system stability and provide the basis for stability analysis of specific real power network.","PeriodicalId":231392,"journal":{"name":"2023 IEEE International Conference on Power Science and Technology (ICPST)","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE International Conference on Power Science and Technology (ICPST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPST56889.2023.10165613","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The rapid development of renewable energy has promoted the development of power electronic devices. A large number of devices represented by voltage source converter (VSC) have been incorporated into the power grid, which has caused a series of stability problems correspondingly. Thus, this paper starts from the distribution feeder parameters and investigates their influence on the stability of the multi-VSC system. In this paper, an improved Kron reduction method is proposed to reduce the order of multi-VSC system equivalently. This method can eliminate unnecessary nodes in any power network which contributes to simplifying later calculation. Then based on the reduced multi-VSC system, the dynamic equation of VSC is established and extended to multi-VSC system. Third, a new system stability criterion is proposed by using the average method. In order to analyze the influence of distribution feeder parameters on multi-VSC system stability, the generalized short circuit ratio calculation formula of the multi-VSC system is introduced. For the real system, the influence of the distribution feeder parameters on the stability of the system can be obtained by finding out the relationship between the new stability criterion proposed in this paper and the generalized short-circuit ratio. The case study has illustrated the effectiveness of the proposed methods. The conclusion of this paper is helpful to study the influence of complex distribution feeder on multi-VSC system stability and provide the basis for stability analysis of specific real power network.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
受配电网参数影响的多vsc系统时域非线性稳定性分析
可再生能源的快速发展促进了电力电子器件的发展。以电压源变换器(VSC)为代表的大量设备被并入电网,相应地引起了一系列的稳定性问题。因此,本文从配电馈线参数入手,研究其对多vsc系统稳定性的影响。本文提出了一种改进的Kron约简方法,对多vsc系统的阶数进行等价约简。该方法可以消除任何电网中不必要的节点,有助于简化后续计算。然后,基于简化后的多VSC系统,建立了VSC的动力学方程,并将其推广到多VSC系统。第三,利用平均法提出了一种新的系统稳定性判据。为了分析配电馈线参数对多vsc系统稳定性的影响,引入了多vsc系统短路比的广义计算公式。对于实际系统,通过找出本文提出的新稳定性判据与广义短路比之间的关系,可以得到配电馈线参数对系统稳定性的影响。实例研究表明了所提方法的有效性。本文的结论有助于研究复杂配电馈线对多vsc系统稳定性的影响,并为具体实际电网的稳定性分析提供依据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Multi- agent Collaborative Optimal Operation Strategy of Microgrid Based on Master-Slave Game Bi-level Programming of Siting and Sizing for Shared Electric Bike Based on Niche Particle Swarm Algorithm Enhancement of External Insulation Performance for Vacuum Interrupters by External Shields Simulation Analysis of Thermal Runaway Characteristics of Lithium-Ion Batteries Marine Predators Algorithm Based Optimal Multicore Cable Topology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1