J. Wright, Casey Rombouts, Bair Michael, J. Barbe, R. Kramer, Z. Krajíček
{"title":"A Comparison of Primary Gas Flow Standards Spanning the Range 10 sccm N2 to 10 slm N2","authors":"J. Wright, Casey Rombouts, Bair Michael, J. Barbe, R. Kramer, Z. Krajíček","doi":"10.51843/wsproceedings.2014.48","DOIUrl":null,"url":null,"abstract":"We describe an international comparison of gas flow standards spanning the range 2.1 x 10-4 g/s (10 sccm) of nitrogen to 0.21 g/s (10 slm) of nitrogen. For all the participating laboratories, |En| 0.78, where En is the difference between the participant’s result and the comparison reference value divided by the uncertainty of this difference. The k = 2 uncertainties (corresponding to 95 % confidence level) of the comparison reference values range from 0.036 % to 0.052 %. These comparison uncertainties include a contribution of 0.042 % from the uncertainty of the three laminar flow elements used as transfer standards. The participating laboratories were: Laboratoire National de Métrologie et d'Essais (LNE), National Institute of Standards and Technology (NIST), Fluke Primary Pressure and Flow Laboratory, Phoenix Arizona USA (FCP), Èeský Metrologický Institut (CMI), and Physikalisch-Technische Bundesanstalt (PTB).","PeriodicalId":446344,"journal":{"name":"NCSL International Workshop & Symposium Conference Proceedings 2014","volume":"465 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NCSL International Workshop & Symposium Conference Proceedings 2014","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51843/wsproceedings.2014.48","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
We describe an international comparison of gas flow standards spanning the range 2.1 x 10-4 g/s (10 sccm) of nitrogen to 0.21 g/s (10 slm) of nitrogen. For all the participating laboratories, |En| 0.78, where En is the difference between the participant’s result and the comparison reference value divided by the uncertainty of this difference. The k = 2 uncertainties (corresponding to 95 % confidence level) of the comparison reference values range from 0.036 % to 0.052 %. These comparison uncertainties include a contribution of 0.042 % from the uncertainty of the three laminar flow elements used as transfer standards. The participating laboratories were: Laboratoire National de Métrologie et d'Essais (LNE), National Institute of Standards and Technology (NIST), Fluke Primary Pressure and Flow Laboratory, Phoenix Arizona USA (FCP), Èeský Metrologický Institut (CMI), and Physikalisch-Technische Bundesanstalt (PTB).