Calibration of acoustic Doppler current profiles

G. Appell, J. Gast, R. Williams, P. Bass
{"title":"Calibration of acoustic Doppler current profiles","authors":"G. Appell, J. Gast, R. Williams, P. Bass","doi":"10.1109/OCEANS.1988.23526","DOIUrl":null,"url":null,"abstract":"The National Ocean Service of NOAA has recently conducted tests and established a laboratory calibration technique for Doppler current profilers. A cooperative effort was established with the manufacturer to assess the technique and the instrument's performance. Several systems ranging in operating frequencies from 300 to 1200 kHz were tested and calibrated. A 1200-kHz system was characterized by the manufacturer through a series of laboratory tests and evaluation runs on a calibrated lake course. This unit was then tested by NOAA for comparison purposes. Calibrations of both bottom track and water track velocity were performed at speeds from 0 to 300 cm/s. Sources of error were investigated by NOAA and the manufacturer. Test results, calibration data, and procedures are discussed.<<ETX>>","PeriodicalId":435174,"journal":{"name":"OCEANS '88. 'A Partnership of Marine Interests'. Proceedings","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"OCEANS '88. 'A Partnership of Marine Interests'. Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OCEANS.1988.23526","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

The National Ocean Service of NOAA has recently conducted tests and established a laboratory calibration technique for Doppler current profilers. A cooperative effort was established with the manufacturer to assess the technique and the instrument's performance. Several systems ranging in operating frequencies from 300 to 1200 kHz were tested and calibrated. A 1200-kHz system was characterized by the manufacturer through a series of laboratory tests and evaluation runs on a calibrated lake course. This unit was then tested by NOAA for comparison purposes. Calibrations of both bottom track and water track velocity were performed at speeds from 0 to 300 cm/s. Sources of error were investigated by NOAA and the manufacturer. Test results, calibration data, and procedures are discussed.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
声学多普勒电流谱校正
美国国家海洋和大气管理局的国家海洋局最近进行了测试,并建立了多普勒电流分析器的实验室校准技术。与制造商建立了合作努力,以评估技术和仪器的性能。测试和校准了几个工作频率从300到1200 kHz的系统。制造商通过一系列实验室测试和在校准的湖航向上进行评估,对1200 khz系统进行了表征。为了比较,NOAA对该装置进行了测试。在0至300 cm/s的速度范围内进行了底部轨迹和水中轨迹速度的校准。NOAA和制造商对误差来源进行了调查。讨论了测试结果、校准数据和程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
DELBUOY: wave-powered seawater desalination system Hydrocarbon potential of the deepwater (600 feet) Gulf of Mexico Results of a Canadian shipborne radar search and rescue detection experiment Design of a semisubmerged swath research and survey ship Art and technology on 20th-century vessels
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1