{"title":"Improving the quality of voltage in the conditions of the oxygen-converter shop of metallurgical production","authors":"G. Kornilov, O. Gazizova, A. Bunin, Mihail Bulanov, A. Karyakin","doi":"10.1109/ICOECS46375.2019.8949928","DOIUrl":null,"url":null,"abstract":"One of the most energy-intensive productions of the metallurgical enterprise is the oxygen-converter. The power consumers of such workshops put high demands on the voltage quality. At the same time, electrical receivers of such workshops can significantly reduce the power quality. The authors had estimated the voltage level in the existing 10 kV network of the oxygen converter shop. The voltage drop below the level allowed by the conditions of work of electrical receivers had been revealed. Causes of voltage reduction in conditions complex configuration network had been determined. A mathematical model has been developed to study the power quality indicators of the workshop in question, taking into account the characteristics of the supply network. The influence of the supply voltage level, the regulatory effect of the load, the load power and the configuration of the supply network on the voltage level had been investigated. A set of measures to improve the quality of the network voltage has been developed. Taking into account the indicators of power quality, compensating devices are recommended for installation. A technical and economic comparison of the installation options for compensating devices has been made, taking into account the power and electricity loss in the supply and distribution network of the workshop. The overall level of loss in the composition of the power consumption of the oxygen converter shop had been evaluated. Its decrease had been shown when introducing recommended measures.","PeriodicalId":371743,"journal":{"name":"2019 International Conference on Electrotechnical Complexes and Systems (ICOECS)","volume":"23 Suppl 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Electrotechnical Complexes and Systems (ICOECS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICOECS46375.2019.8949928","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

One of the most energy-intensive productions of the metallurgical enterprise is the oxygen-converter. The power consumers of such workshops put high demands on the voltage quality. At the same time, electrical receivers of such workshops can significantly reduce the power quality. The authors had estimated the voltage level in the existing 10 kV network of the oxygen converter shop. The voltage drop below the level allowed by the conditions of work of electrical receivers had been revealed. Causes of voltage reduction in conditions complex configuration network had been determined. A mathematical model has been developed to study the power quality indicators of the workshop in question, taking into account the characteristics of the supply network. The influence of the supply voltage level, the regulatory effect of the load, the load power and the configuration of the supply network on the voltage level had been investigated. A set of measures to improve the quality of the network voltage has been developed. Taking into account the indicators of power quality, compensating devices are recommended for installation. A technical and economic comparison of the installation options for compensating devices has been made, taking into account the power and electricity loss in the supply and distribution network of the workshop. The overall level of loss in the composition of the power consumption of the oxygen converter shop had been evaluated. Its decrease had been shown when introducing recommended measures.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
提高冶金生产氧气转炉车间的电压质量
冶金企业最耗能的产品之一是氧气转炉。这类车间的用电量对电压质量要求很高。同时,此类车间的电气接收器可以显著降低电能质量。作者对氧转炉车间现有10kv网络的电压水平进行了估算。电压降低于电气接收机工作条件所允许的水平。确定了复杂结构网络条件下电压降低的原因。考虑到供电网络的特点,建立了一个数学模型来研究该车间的电能质量指标。研究了供电电压水平、负荷调节作用、负荷功率和供电网络结构对电压水平的影响。提出了一套提高电网电压质量的措施。考虑到电能质量指标,建议安装补偿装置。考虑到车间供配电网络的功率和电力损失,对补偿装置的安装方案进行了技术和经济比较。对氧转炉车间能耗构成的总体损失水平进行了评估。在采取建议措施时已显示其减少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Research of the characteristics of bridge sensory modules based on the AMR effect Synchronous Frequency Calculation Based on Synchrophasor Measurements Transformer with a Hybrid Magnetic Core for High-Efficiency Aircraft Transformer-Rectifier Unit Analysis of the Power Consumption of the Booster Pump Station Using Simulation Models of Fluid Control Engineering Calculation of Inductor Parameters for Gas Pipelines
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1