ABOUT INFLUENCE OF PARAMETERS OF A WEAR PLATE OF THE NORMAL PROBE ON CHARACTERISTICS FREQUENCY A SPECTRUM AND A PULSE OF A BOTTOM SIGNAL

V. Danilov
{"title":"ABOUT INFLUENCE OF PARAMETERS OF A WEAR PLATE OF THE NORMAL PROBE ON CHARACTERISTICS FREQUENCY A SPECTRUM AND A PULSE OF A BOTTOM SIGNAL","authors":"V. Danilov","doi":"10.14489/td.2022.04.pp.004-012","DOIUrl":null,"url":null,"abstract":"Computer modelling of an acoustic channel of the normal probe for a reflector as a bottom surface has shown, that increase of amplitude of a pulse echo signal, registered by the probe with a wear plate from epoxy resin with fine – dispersed filler due to increase of its contents, causes reduction of speed of longitudinal waves in a wear plate with the appropriate downturn of the first resonant frequency owing to what the spectrum of a signal may vary essentially. Reception of short pulses, on amplitude of same duration considerably surpassing pulses for protectors from epoxy resin with filler, is provided with application of a protector from mineral ceramics, having own lowest resonant frequency is much higher than the basic own frequency piezo plate. Comparison of experimental and theoretical pulses and spectra of ground signals for direct converters with qualitatively distinguished protectors has confirmed an opportunity of presence of the several expressed maxima of a spectrum of a pulse with oscillating modulation of amplitude for a wear plate from epoxy resin with filler with low speed of distribution of longitudinal waves.","PeriodicalId":432853,"journal":{"name":"Kontrol'. Diagnostika","volume":"44 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kontrol'. Diagnostika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14489/td.2022.04.pp.004-012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Computer modelling of an acoustic channel of the normal probe for a reflector as a bottom surface has shown, that increase of amplitude of a pulse echo signal, registered by the probe with a wear plate from epoxy resin with fine – dispersed filler due to increase of its contents, causes reduction of speed of longitudinal waves in a wear plate with the appropriate downturn of the first resonant frequency owing to what the spectrum of a signal may vary essentially. Reception of short pulses, on amplitude of same duration considerably surpassing pulses for protectors from epoxy resin with filler, is provided with application of a protector from mineral ceramics, having own lowest resonant frequency is much higher than the basic own frequency piezo plate. Comparison of experimental and theoretical pulses and spectra of ground signals for direct converters with qualitatively distinguished protectors has confirmed an opportunity of presence of the several expressed maxima of a spectrum of a pulse with oscillating modulation of amplitude for a wear plate from epoxy resin with filler with low speed of distribution of longitudinal waves.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
关于普通探头磨损盘参数对底部信号特征频率、频谱和脉冲的影响
计算机模拟的声学通道直探头反射器作为底面表明,脉冲回波信号的振幅增加,注册的探针与环氧树脂耐磨护板与细分散填料由于其内容的增加,导致减少纵向波的速度穿板与适当的第一共振频率由于低迷的光谱信号本质上可能会有所不同。采用矿物陶瓷保护器,其自身的最低谐振频率远高于压电板的基本频率,提供了接收短脉冲的能力,其振幅相同的持续时间大大超过填充环氧树脂保护器的脉冲。对具有定性区分保护器的直接变流器的实验脉冲和理论脉冲以及地面信号的频谱进行比较,证实了在纵向波分布速度较低的环氧树脂填充的磨损板中,具有振幅振荡调制的脉冲频谱的几个表示最大值的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
DIAGNOSTICS OF INTERELECTRODE GAP’S CONDITION USING VIBROACOUSTIC EMISSION APPLICATION OF ACOUSTIC EMISSION METHOD FOR DETECTING DIFFUSION INTERLAYERS IN DIFFERENT WELDED JOINTS CALIBRATION OF THE PIEZOELECTRIC DYNAMOMETER KISTLER USING A MEASURING DEVICE BASED ON A SAMPLE COMPRESSION DYNAMOMETER TOPOLOGY OF MANUFACTURING A SORPTION-CAPACITIVE HUMIDITY SENSOR BASED ON THIN FILMS OBTAINED BY MICROARC OXIDATION AND MAGNETRON SPUTTERING INVESTIGATION OF THE TEMPERATURE ERROR OF COORDINATE MEASURING MACHINES
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1