Matched energy modality for non stationary thermal wave imaging

B. Suresh, S. Subhani, S. Suparshya Babu, S. Babu
{"title":"Matched energy modality for non stationary thermal wave imaging","authors":"B. Suresh, S. Subhani, S. Suparshya Babu, S. Babu","doi":"10.1109/SPACES.2015.7058208","DOIUrl":null,"url":null,"abstract":"Active thermographic studies using non stationary coded thermal wave imaging methods facilitate deeper sub surface analysis with better depth resolution even with relatively low peak powers. They exhibit a variation in detection capability due to their diversity in shape and frequency content etc., In order to compare the ability of these schemes in spite of their diversity, a common feature based analysis has been adopted in this contribution. It emphasizes the concept of matched energy among various processing methods used for the subsurface analysis of Barker coded and Digitized Frequency Modulated Thermal Wave Imaging methods. Experimentation has been carried out to find the detectability of different schemes and quantified in terms of signal to noise ratio of subsurface anomalies.","PeriodicalId":432479,"journal":{"name":"2015 International Conference on Signal Processing and Communication Engineering Systems","volume":"116 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Signal Processing and Communication Engineering Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPACES.2015.7058208","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Active thermographic studies using non stationary coded thermal wave imaging methods facilitate deeper sub surface analysis with better depth resolution even with relatively low peak powers. They exhibit a variation in detection capability due to their diversity in shape and frequency content etc., In order to compare the ability of these schemes in spite of their diversity, a common feature based analysis has been adopted in this contribution. It emphasizes the concept of matched energy among various processing methods used for the subsurface analysis of Barker coded and Digitized Frequency Modulated Thermal Wave Imaging methods. Experimentation has been carried out to find the detectability of different schemes and quantified in terms of signal to noise ratio of subsurface anomalies.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
非平稳热波成像的匹配能量模态
主动热成像研究使用非平稳编码热波成像方法,即使在相对较低的峰值功率下,也能以更好的深度分辨率进行更深的地下分析。由于它们在形状和频率内容等方面的多样性,它们表现出检测能力的变化。为了比较这些方案的能力,尽管它们具有多样性,在本贡献中采用了基于共同特征的分析。强调了巴克编码和数字化调频热波成像方法在地下分析中所使用的各种处理方法之间的能量匹配概念。实验研究了不同方案的可探测性,并对地下异常的信噪比进行了量化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
BTSWASH: Brain tumour segmentation by water shed algorithm Path loss prediction analysis by ray tracing approach for NLOS indoor propagation Enhancing the performance of AOA estimation in wireless communication using the MUSIC algorithm Preventing black hole attacks in MANETs using secure knowledge algorithm Redundancy based WEP routing technology (IoT-WSN)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1