{"title":"Near-Field Techniques for Millimeter-Wave Antenna Array Calibration","authors":"Gerhard F. Hamberger, C. Rowell, B. Derat","doi":"10.23919/AMTAP.2019.8906415","DOIUrl":null,"url":null,"abstract":"A reliable technique for antenna array characterization and calibration is demonstrated for two state-of-the-art antenna measurement systems, a near-field system and a compact antenna test range system. Both systems are known to reduce the measurement distance between device under test and the probe antenna in comparison to classical far-field systems, which need to provide at least the Fraunhofer distance as minimum range length. Equivalent magnetic surface currents are derived from measurements, which represent the electric field on the applied Huygens surface. The calculated equivalent magnetic currents are utilized for characterizing two completely different antenna arrays in the millimeter-wave region. Magnitude and phase calibration opportunities of antenna arrays are discussed, as well as the accuracy provided by the proposed calibration technique.","PeriodicalId":339768,"journal":{"name":"2019 Antenna Measurement Techniques Association Symposium (AMTA)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Antenna Measurement Techniques Association Symposium (AMTA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/AMTAP.2019.8906415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
A reliable technique for antenna array characterization and calibration is demonstrated for two state-of-the-art antenna measurement systems, a near-field system and a compact antenna test range system. Both systems are known to reduce the measurement distance between device under test and the probe antenna in comparison to classical far-field systems, which need to provide at least the Fraunhofer distance as minimum range length. Equivalent magnetic surface currents are derived from measurements, which represent the electric field on the applied Huygens surface. The calculated equivalent magnetic currents are utilized for characterizing two completely different antenna arrays in the millimeter-wave region. Magnitude and phase calibration opportunities of antenna arrays are discussed, as well as the accuracy provided by the proposed calibration technique.