Multichannel ECG Filtering: Source Consistency Filtering, Eigenfiltering and Traditional Methods

L. Bachi, M. Varanini, Magda Costi, D. Lombardi, F. Rangoni, L. Billeci
{"title":"Multichannel ECG Filtering: Source Consistency Filtering, Eigenfiltering and Traditional Methods","authors":"L. Bachi, M. Varanini, Magda Costi, D. Lombardi, F. Rangoni, L. Billeci","doi":"10.22489/CinC.2022.168","DOIUrl":null,"url":null,"abstract":"Noise reduction is a fundamental aspect of stress electrocardiogram <tex>$(ECG)$</tex> recording. In this setting, muscular noise represents the main antagonist to signal quality. A possible solution to muscle noise in stress <tex>$ECG$</tex> is to exploit the information redundancy in 12 - lead recordings to reduce noise while preserving the <tex>$ECG$</tex> signal. Source Consistency Filtering <tex>$(SCF)$</tex> is a spatial redundancy filter that follows this principle. In this paper, we compare the muscle noise rejection performance of conventional <tex>$25Hz$</tex> and <tex>$40Hz$</tex> low-pass filters (LPFs), the SC <tex>$F$</tex> ‘ and a method based on singular value decomposition <tex>$(SVD)$</tex> which exploits both the spatial and temporal correlation in the <tex>$ECG$</tex> signal. Our results indicate that the <tex>$SCF$</tex> can afford a <tex>$QRS$</tex> complex distortion lower than that of a 40 <tex>$Hz$</tex> lowpass filter while still maintaining a high noise rejection. The <tex>$QRS$</tex> detection accuracy on the filtered <tex>$ECG$</tex> was comparable for all methods except for the <tex>$SVD$</tex> filter, which allowed a superior detection performance score in all the records.","PeriodicalId":117840,"journal":{"name":"2022 Computing in Cardiology (CinC)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Computing in Cardiology (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22489/CinC.2022.168","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Noise reduction is a fundamental aspect of stress electrocardiogram $(ECG)$ recording. In this setting, muscular noise represents the main antagonist to signal quality. A possible solution to muscle noise in stress $ECG$ is to exploit the information redundancy in 12 - lead recordings to reduce noise while preserving the $ECG$ signal. Source Consistency Filtering $(SCF)$ is a spatial redundancy filter that follows this principle. In this paper, we compare the muscle noise rejection performance of conventional $25Hz$ and $40Hz$ low-pass filters (LPFs), the SC $F$ ‘ and a method based on singular value decomposition $(SVD)$ which exploits both the spatial and temporal correlation in the $ECG$ signal. Our results indicate that the $SCF$ can afford a $QRS$ complex distortion lower than that of a 40 $Hz$ lowpass filter while still maintaining a high noise rejection. The $QRS$ detection accuracy on the filtered $ECG$ was comparable for all methods except for the $SVD$ filter, which allowed a superior detection performance score in all the records.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
多通道心电滤波:源一致性滤波、特征滤波和传统方法
降噪是应激心电图记录的一个基本方面。在这种情况下,肌肉噪声代表信号质量的主要拮抗剂。一种可能的解决方案是利用12导联记录中的信息冗余来减少噪声,同时保留ECG信号。源一致性过滤$(Source Consistency Filtering, SCF)$是一种遵循此原则的空间冗余过滤器。在本文中,我们比较了传统的$25Hz$和$40Hz$低通滤波器(lpf), SC $F$和基于奇异值分解(SVD)的方法(该方法利用了$ECG$信号的空间和时间相关性)的肌肉噪声抑制性能。我们的结果表明,SCF可以承受比40 Hz低通滤波器更低的QRS复杂失真,同时仍然保持高噪声抑制。除SVD过滤器外,过滤后的ECG的QRS检测精度与所有方法相当,SVD过滤器允许在所有记录中获得更高的检测性能分数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Nonlinear Dynamic Response of Intrapartum Fetal Heart Rate to Uterine Pressure Heart Pulse Demodulation from Emfit Mattress Sensor Using Spectral and Source Separation Techniques Automated Algorithm for QRS Detection in Cardiac Arrest Patients with PEA Extraction Algorithm for Morphologically Preserved Non-Invasive Multi-Channel Fetal ECG Improved Pulse Pressure Estimation Based on Imaging Photoplethysmographic Signals
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1