Experimental Study on Applicability of Passive Electric Potential CT Method for Identification of Three-Dimensional Surface Crack

D. Shiozawa, S. Kubo, T. Sakagami
{"title":"Experimental Study on Applicability of Passive Electric Potential CT Method for Identification of Three-Dimensional Surface Crack","authors":"D. Shiozawa, S. Kubo, T. Sakagami","doi":"10.1299/JSMEA.49.426","DOIUrl":null,"url":null,"abstract":"In this paper, we examine the applicability of the passive electric potential CT (computed tomography) method to the quantitative identification of three-dimensional cracks in structures. In this method, a piezoelectric film is glued on the surface of structures. The electric potential values on the piezoelectric film change due to the strain distribution on the surface of the structures, when the structures are subjected to an external load. The strain distribution induces an electric potential distribution on the piezoelectric film. Then, this method does not require electric current application, and passively observed electric potential values on piezoelectric film can be used for crack identification. The electric potential distribution on piezoelectric film was investigated numerically and experimentally. It was found that the electric potential distribution shows a characteristic change corresponding to the shape of the surface crack. An inverse method based on the least residual method was applied to crack identification from the electric potential distribution. In this inverse method, the square sum of residuals is evaluated between the measured electric potential distributions and those computed from the electric potential distribution of the piezoelectric film. Three-dimensional surface cracks were identified from the measured electric potential distribution. It was found that the location and size of the crack can be quantitatively estimated using a two-dimensional distribution of electric potential.","PeriodicalId":170519,"journal":{"name":"Jsme International Journal Series A-solid Mechanics and Material Engineering","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jsme International Journal Series A-solid Mechanics and Material Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1299/JSMEA.49.426","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

In this paper, we examine the applicability of the passive electric potential CT (computed tomography) method to the quantitative identification of three-dimensional cracks in structures. In this method, a piezoelectric film is glued on the surface of structures. The electric potential values on the piezoelectric film change due to the strain distribution on the surface of the structures, when the structures are subjected to an external load. The strain distribution induces an electric potential distribution on the piezoelectric film. Then, this method does not require electric current application, and passively observed electric potential values on piezoelectric film can be used for crack identification. The electric potential distribution on piezoelectric film was investigated numerically and experimentally. It was found that the electric potential distribution shows a characteristic change corresponding to the shape of the surface crack. An inverse method based on the least residual method was applied to crack identification from the electric potential distribution. In this inverse method, the square sum of residuals is evaluated between the measured electric potential distributions and those computed from the electric potential distribution of the piezoelectric film. Three-dimensional surface cracks were identified from the measured electric potential distribution. It was found that the location and size of the crack can be quantitatively estimated using a two-dimensional distribution of electric potential.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
被动电位CT法识别三维表面裂纹适用性的实验研究
在本文中,我们研究了被动电位CT(计算机断层扫描)方法在结构三维裂缝定量识别中的适用性。在这种方法中,压电薄膜被粘在结构的表面。当结构受到外部载荷作用时,由于结构表面的应变分布,使得压电膜上的电势值发生变化。应变分布导致压电薄膜上的电位分布。其次,该方法不需要施加电流,可以通过被动观察压电膜上的电势值进行裂纹识别。对压电薄膜上的电势分布进行了数值和实验研究。结果表明,电势分布随表面裂纹形状的变化呈特征性变化。将基于最小残差法的逆方法应用于电势分布的裂纹识别。该方法利用实测电势分布与压电薄膜电势分布计算结果的差值平方和进行计算。根据测得的电势分布,确定了三维表面裂纹。研究发现,利用二维电势分布可以定量估计裂纹的位置和大小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation of Initiation of the Interfacial Debonding in Single Fiber Composite Two Back Stress Hardening Models in Rate Independent Rigid Plastic Deformation Two Collinear Interface Cracks between Two Dissimilar Functionally Graded Piezoelectric/Piezomagnetic Material Layers under Anti-Plane Shear Loading Investigation the Dynamic Interaction between Two Collinear Cracks in the Functionally Graded Piezoelectric Materials Subjected to the Harmonic Anti-Plane Shear Stress Waves by Using the Non-Local Theory Development of a Finite Element Contact Analysis Algorithm to Pass the Patch Test
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1