Diffraction enhanced breast imaging: assessment of realistic system requirements to improve the diagnostic capabilities of mammography

J. Griffiths, G. Royle, R. Speller, J. Horrocks, A. Olivo, S. Pani, R. Longo, S. Spencer, M. Robbins, D.P. Clifford, A. Hanby
{"title":"Diffraction enhanced breast imaging: assessment of realistic system requirements to improve the diagnostic capabilities of mammography","authors":"J. Griffiths, G. Royle, R. Speller, J. Horrocks, A. Olivo, S. Pani, R. Longo, S. Spencer, M. Robbins, D.P. Clifford, A. Hanby","doi":"10.1109/NSSMIC.2003.1352586","DOIUrl":null,"url":null,"abstract":"A detectable difference in X-ray diffraction data of healthy and diseased breast tissues has been observed. This information can be used to generate images with a higher contrast than that of conventional transmission mammography. A diffraction enhanced breast imaging (DEBI) system that simultaneously combines transmission and diffraction breast images is currently being developed. This paper presents the imaging system requirements for a clinical DEBI system. The DEBI imaging system employs a phosphor coated L3Vision CCD camera. The DEBI principle has been assessed at the SYRMEP synchrotron beamline (Elettra, Trieste) and with a purpose built mammographic X-ray imaging unit. Diffraction enhanced images have been obtained of realistic breast tissue phantoms, consisting of 4 cm thick slabs of excised breast tissue containing embedded carcinomas. The images were obtained at pre-determined momentum transfer values, allowing some tissue characterization to be achieved during imaging, as well as optimizing image contrast This paper presents the current state of the project. The spatial resolution of the diffraction images have been studied using test phantoms and suggestions are made for the collimation systems necessary for a clinical system. A correction procedure applied to the diffraction images is also presented.","PeriodicalId":186175,"journal":{"name":"2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)","volume":"189 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2003.1352586","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

A detectable difference in X-ray diffraction data of healthy and diseased breast tissues has been observed. This information can be used to generate images with a higher contrast than that of conventional transmission mammography. A diffraction enhanced breast imaging (DEBI) system that simultaneously combines transmission and diffraction breast images is currently being developed. This paper presents the imaging system requirements for a clinical DEBI system. The DEBI imaging system employs a phosphor coated L3Vision CCD camera. The DEBI principle has been assessed at the SYRMEP synchrotron beamline (Elettra, Trieste) and with a purpose built mammographic X-ray imaging unit. Diffraction enhanced images have been obtained of realistic breast tissue phantoms, consisting of 4 cm thick slabs of excised breast tissue containing embedded carcinomas. The images were obtained at pre-determined momentum transfer values, allowing some tissue characterization to be achieved during imaging, as well as optimizing image contrast This paper presents the current state of the project. The spatial resolution of the diffraction images have been studied using test phantoms and suggestions are made for the collimation systems necessary for a clinical system. A correction procedure applied to the diffraction images is also presented.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
衍射增强乳房成像:评估现实的系统要求,以提高乳房x光检查的诊断能力
已观察到健康和患病乳腺组织的x射线衍射数据的可检测差异。该信息可用于生成比传统传输乳房x线摄影具有更高对比度的图像。目前正在开发一种同时结合透射和衍射乳房图像的衍射增强乳房成像系统。本文介绍了临床DEBI系统的成像系统要求。DEBI成像系统采用了一个涂有荧光粉的L3Vision CCD相机。DEBI原理已经在symep同步加速器光束线(Elettra, Trieste)和专门建造的乳房x射线成像单元上进行了评估。衍射增强图像已经获得了真实的乳房组织幻象,由4厘米厚的切除的乳房组织板组成,其中含有嵌入的癌。图像是在预先确定的动量传递值下获得的,可以在成像过程中获得一些组织特征,并优化图像对比度。本文介绍了该项目的当前状态。利用测试幻影对衍射图像的空间分辨率进行了研究,并对临床系统所需的准直系统提出了建议。提出了一种适用于衍射图像的校正方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Proton irradiation response of CsI(Tl) crystals for the GLAST calorimeter Comparative study of PP0275C hybrid photodetector and XP2020Q photomultiplier in scintillation detection Quality of mass produced lead tungstate crystals SLIM (Secondary emission monitor for Low Interception Monitoring) an innovative non-destructive beam monitor for the extraction lines of a hadrontherapy center Single electron amplification in a "Single-MCP + micromegas + pads" detector
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1