{"title":"The Relationship Between the Space Corridor and Pedestrian-Level Wind Environment","authors":"Hongwei Zhang","doi":"10.1109/ICVISP54630.2021.00035","DOIUrl":null,"url":null,"abstract":"The unreasonable building layout will worsen the wind environment at the pedestrian height around the building. The main objective of this paper is that using ANSYS Fluent software to study the impact of space corridors on pedestrian-level wind environment around buildings and give a reasonable space corridor layout position. In this paper, the calculation model was set up according to the detailed rules of green building evaluation standard to ensure the validity of CFD simulation. Based on the calculation results, the variation laws of different space corridor arrangements on the average wind speed amplification coefficient at pedestrian height in 3 evaluation areas were discussed. It is concluded that the layout of the space corridor in the middle of the buildings which is case-3 is beneficial to the pedestrian wind environment in the street valley of the buildings.","PeriodicalId":296789,"journal":{"name":"2021 5th International Conference on Vision, Image and Signal Processing (ICVISP)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 5th International Conference on Vision, Image and Signal Processing (ICVISP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICVISP54630.2021.00035","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The unreasonable building layout will worsen the wind environment at the pedestrian height around the building. The main objective of this paper is that using ANSYS Fluent software to study the impact of space corridors on pedestrian-level wind environment around buildings and give a reasonable space corridor layout position. In this paper, the calculation model was set up according to the detailed rules of green building evaluation standard to ensure the validity of CFD simulation. Based on the calculation results, the variation laws of different space corridor arrangements on the average wind speed amplification coefficient at pedestrian height in 3 evaluation areas were discussed. It is concluded that the layout of the space corridor in the middle of the buildings which is case-3 is beneficial to the pedestrian wind environment in the street valley of the buildings.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
空间廊道与行人风环境的关系
不合理的建筑布局会使建筑周围行人高度处的风环境恶化。本文的主要目的是利用ANSYS Fluent软件研究空间廊道对建筑周围行人层风环境的影响,给出合理的空间廊道布局位置。本文根据绿色建筑评价标准细则建立了计算模型,以保证CFD模拟的有效性。根据计算结果,探讨了3个评价区不同空间廊道布置方式对行人高度处平均风速放大系数的变化规律。结果表明,案例3所示的建筑中间空间廊道布局有利于建筑街谷的行人风环境。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Observability and Performance Analysis of Spacecraft Autonomous Navigation Using Stellar Aberration Observation The Study of Methods to Improve the Accuracy of Glycemic Control Based on Statistical Methods [Copyright notice] Carbon-Dioxide Mitigation of Prefabricated Residential Buildings in China: an Urbanization-Based Estimation A Digital Twin Based Design of the Semi-physical Marine Engine Room Simulator for Remote Maintenance Assistance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1