Optimally testing numerical multi-function generator protection elements

S. Turner
{"title":"Optimally testing numerical multi-function generator protection elements","authors":"S. Turner","doi":"10.1109/CPRE.2014.6799028","DOIUrl":null,"url":null,"abstract":"A numerical generator protection relay provides multiple functions and typically uses algorithms that do not work on the same principles as older electromechanical relays. Often relay test personnel still want to use old test methods developed long ago for electromechanical relays. Test results obtained from these old test methods may not be a good indication of whether or not the numerical relay protection functions properly. One such obsolete technique still often used is referred to as a static test. Fault voltage and/or fault current are injected to see if the selected protection function operates at the setpoint and is in tolerance. Many protection functions have dynamic characteristics and/or hidden features that cannot be properly tested using a static test. This paper demonstrates various techniques how to test numerical protection relays such as dynamic tests.","PeriodicalId":285252,"journal":{"name":"2014 67th Annual Conference for Protective Relay Engineers","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 67th Annual Conference for Protective Relay Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPRE.2014.6799028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A numerical generator protection relay provides multiple functions and typically uses algorithms that do not work on the same principles as older electromechanical relays. Often relay test personnel still want to use old test methods developed long ago for electromechanical relays. Test results obtained from these old test methods may not be a good indication of whether or not the numerical relay protection functions properly. One such obsolete technique still often used is referred to as a static test. Fault voltage and/or fault current are injected to see if the selected protection function operates at the setpoint and is in tolerance. Many protection functions have dynamic characteristics and/or hidden features that cannot be properly tested using a static test. This paper demonstrates various techniques how to test numerical protection relays such as dynamic tests.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
优化测试数字多功能发电机保护元件
数字发生器保护继电器提供多种功能,通常使用的算法与旧的机电继电器的原理不同。通常继电器测试人员仍然希望使用很久以前开发的机电继电器的旧测试方法。从这些旧的测试方法中获得的测试结果可能不能很好地指示数字继电保护是否正常工作。其中一种仍然经常使用的过时技术被称为静态测试。注入故障电压和/或故障电流,以查看所选保护功能是否在设定值处运行并在公差范围内。许多保护功能具有动态特性和/或隐藏特性,无法使用静态测试进行适当测试。介绍了数值保护继电器动态测试等各种测试技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Testing the tester, common pitfalls testing Microprocessor based relays Improvements in the operation of a distance relay during resistive faults Preventing transformer mis-operations for external faults Open-circuited CT misoperation and investigation Enhanced distribution feeder fault location
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1