{"title":"Quick Design of Air Vents for Power Intakes","authors":"G. S. Sarkaria, O. S. Hom","doi":"10.1061/JPWEAM.0000284","DOIUrl":null,"url":null,"abstract":"For closed conduit systems without surge tanks, common parameter is derived and correlated with vent diameter as used in 35 hydroelectric installations; empirical equation for solution of vent diameter size requires knowledge of only rated head, output of turbine, and length of vent; graphic solution is also given.","PeriodicalId":136288,"journal":{"name":"Journal of the Power Division","volume":"418 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1960-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Power Division","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1061/JPWEAM.0000284","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
For closed conduit systems without surge tanks, common parameter is derived and correlated with vent diameter as used in 35 hydroelectric installations; empirical equation for solution of vent diameter size requires knowledge of only rated head, output of turbine, and length of vent; graphic solution is also given.