Giljun Ahn, Junmin Lee, C. Park, Myeongbaek Youn, B. Youn
{"title":"Inter-turn Short Circuit Fault Detection in Permanent Magnet Synchronous Motors Based on Reference Voltage","authors":"Giljun Ahn, Junmin Lee, C. Park, Myeongbaek Youn, B. Youn","doi":"10.1109/DEMPED.2019.8864924","DOIUrl":null,"url":null,"abstract":"This paper proposes a method for detecting inter-turn short circuit faults of surface-mounted permanent magnet synchronous motors (SPMSMs) based on reference voltage. The proposed method consists of three steps. First, from the mathematical model of faulty PMSM, a reference voltage vector in the dq-frame is separated into a healthy voltage and a faulty voltage. Second, the faulty voltage is further decomposed into a DC component and a 2nd harmonic component. Third, the relationship between these components and the inter-turn fault severity is identified. Based on the relationship, this paper proposes two fault indicators; DC bias and 2nd harmonic amplitude. Simulation results verify the effectiveness of the proposed method. The proposed method can detect inter-turn short circuit faults under low sampling rate and without the need for additional sensors. This strength can facilitate on-line fault detection.","PeriodicalId":397001,"journal":{"name":"2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEMPED.2019.8864924","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7
Abstract
This paper proposes a method for detecting inter-turn short circuit faults of surface-mounted permanent magnet synchronous motors (SPMSMs) based on reference voltage. The proposed method consists of three steps. First, from the mathematical model of faulty PMSM, a reference voltage vector in the dq-frame is separated into a healthy voltage and a faulty voltage. Second, the faulty voltage is further decomposed into a DC component and a 2nd harmonic component. Third, the relationship between these components and the inter-turn fault severity is identified. Based on the relationship, this paper proposes two fault indicators; DC bias and 2nd harmonic amplitude. Simulation results verify the effectiveness of the proposed method. The proposed method can detect inter-turn short circuit faults under low sampling rate and without the need for additional sensors. This strength can facilitate on-line fault detection.