{"title":"A high displacement ultrasonic horn with a cuboid hole in the front end","authors":"He Xiping, Cui Xiaojuan, W. Yanjun, Ning jingfeng","doi":"10.1109/IBCAST.2019.8667192","DOIUrl":null,"url":null,"abstract":"In ultrasonic machining and processing or in underwater acoustics, the output end surface of a vibration system needs large amplitude to improve work efficiency. A uniform horn with a cuboid hole at front end is proposed for amplifying amplitude. The finite element method is used to calculate the displacement distribution, magnification factor of the output end surface and to optimize the geometrical size and the position of the cuboid hole at resonant frequency. The influence of position and geometrical size of the hole on resonant frequency of the horn is studied, and the maximum magnification factor can reach seven times greater than that of a uniform solid horn after optimization. The horn is connected to a longitudinal vibration transducer, the frequency, mode shape, displacement distribution of the output surface, and the amplitude magnification factor were measured by using a laser vibrometer. The experimental results were consistent with the analysis of the finite element calculation results. In addition, the test results also show that excitation voltage has a linear relationship with the output displacement of the horn.","PeriodicalId":335329,"journal":{"name":"2019 16th International Bhurban Conference on Applied Sciences and Technology (IBCAST)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 16th International Bhurban Conference on Applied Sciences and Technology (IBCAST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IBCAST.2019.8667192","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In ultrasonic machining and processing or in underwater acoustics, the output end surface of a vibration system needs large amplitude to improve work efficiency. A uniform horn with a cuboid hole at front end is proposed for amplifying amplitude. The finite element method is used to calculate the displacement distribution, magnification factor of the output end surface and to optimize the geometrical size and the position of the cuboid hole at resonant frequency. The influence of position and geometrical size of the hole on resonant frequency of the horn is studied, and the maximum magnification factor can reach seven times greater than that of a uniform solid horn after optimization. The horn is connected to a longitudinal vibration transducer, the frequency, mode shape, displacement distribution of the output surface, and the amplitude magnification factor were measured by using a laser vibrometer. The experimental results were consistent with the analysis of the finite element calculation results. In addition, the test results also show that excitation voltage has a linear relationship with the output displacement of the horn.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种在前端有长方体孔的高位移超声变幅器
在超声加工加工或水下声学中,振动系统的输出端面需要较大的振幅来提高工作效率。为了放大振幅,提出了一种均匀的喇叭,其前端有一个长方体孔。采用有限元法计算了输出端面的位移分布和放大系数,优化了长方体孔在谐振频率下的几何尺寸和位置。研究了孔的位置和几何尺寸对变幅器谐振频率的影响,优化后的最大放大倍数可达到均匀实心变幅器的7倍。将喇叭与纵向振动换能器相连,利用激光测振仪测量了喇叭输出面的频率、模态振型、位移分布和振幅放大系数。实验结果与有限元计算结果分析一致。此外,试验结果还表明,励磁电压与喇叭输出位移呈线性关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparative Survey of Techniques and Technologies Used in Transmit Path of Transmit Receive Module of AESA Radar Testing-based Model Learning Approach for Legacy Components Pic Microcontroller Based Power Factor Correction for both Leading and Lagging Loads using Compensation Method Speed Tracking of Spark Ignition Engines using Higher Order Sliding Mode Control Survey of Authentication Schemes for Health Monitoring: A Subset of Cyber Physical System
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1