Optimal coordination of directional overcurrent relays in a microgrid system using a hybrid particle swarm optimization

Y. Damchi, H. R. Mashhadi, J. Sadeh, M. Bashir
{"title":"Optimal coordination of directional overcurrent relays in a microgrid system using a hybrid particle swarm optimization","authors":"Y. Damchi, H. R. Mashhadi, J. Sadeh, M. Bashir","doi":"10.1109/APAP.2011.6180976","DOIUrl":null,"url":null,"abstract":"Recently, microgrid operation increased significantly with increasing distributed renewable energy resources in the power system. Microgrids can operate with and without utility. Fault currents are significantly different in island and utility connected operation modes. Therefore, microgrid protection is one of the important subjects in microgrid operation. In this paper, a hybrid particle swarm optimization (HPSO) approach has been developed for coordination of directional overcurrent relays (DOCRs) in a microgrid system. The coordination constraints include the utility connected and an autonomous condition of the microgrid operation. In the optimization procedure, the current setting (Iset) of relays is considered as discrete parameters and time multiplier settings (TMS) is assumed as continues parameter. The proposed algorithm has two parts, in the first part, PSO is used to calculate the Iset and in the second part, linear programming is applied to calculate the TMS of each relay. In the case study, loads connected to the network are divided into critical and noncritical ones. In normal operation of the system, distributed generators (DGs) operate in parallel with the utility. When a fault occurs on the utility side, noncritical loads are disconnected from the network and DGs are operated in microgrid as islanded mode. Regarding to simulation results, DOCRs have a suitable and reliable operation in both conditions of microgrid operations. In addition, overall operating time of the primary relays is properly minimized.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"31","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Advanced Power System Automation and Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APAP.2011.6180976","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 31

Abstract

Recently, microgrid operation increased significantly with increasing distributed renewable energy resources in the power system. Microgrids can operate with and without utility. Fault currents are significantly different in island and utility connected operation modes. Therefore, microgrid protection is one of the important subjects in microgrid operation. In this paper, a hybrid particle swarm optimization (HPSO) approach has been developed for coordination of directional overcurrent relays (DOCRs) in a microgrid system. The coordination constraints include the utility connected and an autonomous condition of the microgrid operation. In the optimization procedure, the current setting (Iset) of relays is considered as discrete parameters and time multiplier settings (TMS) is assumed as continues parameter. The proposed algorithm has two parts, in the first part, PSO is used to calculate the Iset and in the second part, linear programming is applied to calculate the TMS of each relay. In the case study, loads connected to the network are divided into critical and noncritical ones. In normal operation of the system, distributed generators (DGs) operate in parallel with the utility. When a fault occurs on the utility side, noncritical loads are disconnected from the network and DGs are operated in microgrid as islanded mode. Regarding to simulation results, DOCRs have a suitable and reliable operation in both conditions of microgrid operations. In addition, overall operating time of the primary relays is properly minimized.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于混合粒子群算法的微电网定向过流继电器优化协调
近年来,随着电力系统中分布式可再生能源的增加,微网运行显著增加。微电网可以在有或没有公用事业的情况下运行。故障电流在孤岛和公用事业连接运行模式下有显著差异。因此,微网保护是微网运行的重要课题之一。本文提出了一种基于混合粒子群优化的定向过流继电器协调方法。协调约束包括公用事业接入条件和微网运行的自治条件。在优化过程中,将继电器的电流整定(Iset)视为离散参数,将时间乘法器整定(TMS)视为连续参数。该算法分为两部分,第一部分采用粒子群算法计算isset,第二部分采用线性规划方法计算各继电器的TMS。在案例研究中,将连接到网络的负载分为关键负载和非关键负载。在系统的正常运行中,分布式发电机(dg)与公用事业并联运行。当公用事业侧发生故障时,非关键负荷与电网断开,dg以孤岛模式在微电网中运行。仿真结果表明,在微网运行的两种情况下,docr都具有合适可靠的运行方式。此外,适当地减少了一次继电器的总操作时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Matlab-based voltage stability analysis toolbox and its validity check Fault indicator allocation in power distribution network for improving reliability and fault section estimation Effect of monitoring and self-checking tests effectiveness index of back-up protection system on the optimum routine and self-checking test intervals of protection system A new method to prevent distance protection from operating due to power swing Coordination of overcurrent and distance relays using hybrid Particle Swarm Optimization
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1