{"title":"High accuracy, low temperature coefficient bandgap voltage reference","authors":"S. Strik, V. Strik","doi":"10.1109/BEC.2010.5630057","DOIUrl":null,"url":null,"abstract":"The design of CMOS bandgap voltage references focusing on high accuracy and low temperature coefficient methodologies is discussed in this paper. Several solutions of total bandgap voltage reference error minimization are considered. As a summary it is proposed bandgap voltage reference with output voltage accuracy 1.2V ± 0.08% in temperature range −40∶125°C.","PeriodicalId":228594,"journal":{"name":"2010 12th Biennial Baltic Electronics Conference","volume":"320 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 12th Biennial Baltic Electronics Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BEC.2010.5630057","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The design of CMOS bandgap voltage references focusing on high accuracy and low temperature coefficient methodologies is discussed in this paper. Several solutions of total bandgap voltage reference error minimization are considered. As a summary it is proposed bandgap voltage reference with output voltage accuracy 1.2V ± 0.08% in temperature range −40∶125°C.