Real-time communication platform for Smart Grid adaptive Volt-VAR Optimization of distribution networks

M. Manbachi, A. Sadu, H. Farhangi, A. Monti, A. Palizban, F. Ponci, S. Arzanpour
{"title":"Real-time communication platform for Smart Grid adaptive Volt-VAR Optimization of distribution networks","authors":"M. Manbachi, A. Sadu, H. Farhangi, A. Monti, A. Palizban, F. Ponci, S. Arzanpour","doi":"10.1109/SEGE.2015.7324592","DOIUrl":null,"url":null,"abstract":"This paper investigates a real-time communication platform for a Smart Grid adaptive Volt-VAR Optimization (VVO) engine. Novel VVO techniques receive inputs from Advanced Metering Infrastructure (AMI) to dynamically optimize distribution networks. As communication platform design and characteristics affect Smart Grid-based VVO performance in terms of control accuracy and response time, VVO ICT studies is essential for grid planners and/or power utilities. Hence, this paper primarily introduces a real-time co-simulated environment comprised of Smart Grid adaptive VVO engine, RTDS model and system communication platform using DNP3 protocol. This platform is built to test and asses the influence of different components included in Smart Grid monitoring and control system; namely the sensors, measurement units, communication infrastructure on the operation and control of VVO. Moreover, this paper uses a real-time platform to check the robustness of the monitoring and control applications for communication network considerations such as delays and packet loss. Next, this paper investigates how such a platform could look into communication issues while taking system requirements into consideration. A 33-node distribution feeder is employed to check system performance through communication parameters such as throughput and response time.","PeriodicalId":409488,"journal":{"name":"2015 IEEE International Conference on Smart Energy Grid Engineering (SEGE)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Conference on Smart Energy Grid Engineering (SEGE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SEGE.2015.7324592","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

This paper investigates a real-time communication platform for a Smart Grid adaptive Volt-VAR Optimization (VVO) engine. Novel VVO techniques receive inputs from Advanced Metering Infrastructure (AMI) to dynamically optimize distribution networks. As communication platform design and characteristics affect Smart Grid-based VVO performance in terms of control accuracy and response time, VVO ICT studies is essential for grid planners and/or power utilities. Hence, this paper primarily introduces a real-time co-simulated environment comprised of Smart Grid adaptive VVO engine, RTDS model and system communication platform using DNP3 protocol. This platform is built to test and asses the influence of different components included in Smart Grid monitoring and control system; namely the sensors, measurement units, communication infrastructure on the operation and control of VVO. Moreover, this paper uses a real-time platform to check the robustness of the monitoring and control applications for communication network considerations such as delays and packet loss. Next, this paper investigates how such a platform could look into communication issues while taking system requirements into consideration. A 33-node distribution feeder is employed to check system performance through communication parameters such as throughput and response time.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
配电网自适应电压无功优化的智能电网实时通信平台
本文研究了智能电网自适应电压无功优化引擎的实时通信平台。新的VVO技术接收来自先进计量基础设施(AMI)的输入,以动态优化配电网。由于通信平台的设计和特性在控制精度和响应时间方面影响基于智能电网的VVO性能,因此VVO ICT研究对于电网规划者和/或电力公司至关重要。因此,本文主要介绍了一个由智能电网自适应VVO引擎、RTDS模型和采用DNP3协议的系统通信平台组成的实时协同仿真环境。该平台的建立是为了测试和评估智能电网监控系统中不同组件的影响;即传感器、测量单元、通信基础设施对VVO的运行和控制。此外,本文还利用实时平台对通信网络中时延、丢包等监控应用的鲁棒性进行了检验。接下来,本文研究了这样一个平台如何在考虑系统需求的同时研究通信问题。采用33节点分布馈线,通过吞吐量、响应时间等通信参数检查系统性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design optimization model for the United Arab Emirates power sector under uncertainty Offering strategy of a Plug-in Electric Vehicle parking lot in renewable-based distribution networks Optimal planned scheduling of distributed generators in microgrids Soft computing approach for solar radiation prediction over Abu Dhabi, UAE: A comparative analysis Operation reliability analysis of single busbar power distribution network using statistics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1