Validation of a Customized Method for Estimating Electrical Potentials in the Torso From Atrial Signals: a Computational-Clinical Study

Camila R Restivo, Gabriel V Costa, I. Sandoval, M. Guillem, J. Salinet
{"title":"Validation of a Customized Method for Estimating Electrical Potentials in the Torso From Atrial Signals: a Computational-Clinical Study","authors":"Camila R Restivo, Gabriel V Costa, I. Sandoval, M. Guillem, J. Salinet","doi":"10.22489/CinC.2022.369","DOIUrl":null,"url":null,"abstract":"Atrial fibrillation (AF) is a common supraventricular arrhythmia (SVA) in clinical practice and is characterized by uncoordinated electrical activity of the atria. This study aims to evaluate the influence on the forward solution of AF torso biomarkers under different levels of noise, 3D cardiorespiratory torso/atria morphologies, and number of atria electrodes. 2,048 atrial epicardium electrograms (AEGs) from 5 AF mathematical models were used to estimate 771 body surface potentials (BSPs). The BSPs and respective frequency/phase maps of are obtained after: (i) introduction of noise in the AEGs, (ii) 3D geometry torso/atria modification, and (iii) reduction in electrodes (from 2,048 to 256, 128, 64 e 32; interpolation methods: Linear/Laplacian). To reduce biomarkers disparity, a Butterworth bandpass filter (BPF) at different cut-off frequencies (0.5-30, 3–30 and HDF±1 Hz) is applied on the AEGs prior BSPs estimation. The above methodology is extended to two AF patients (EDGAR database). The estimation of AF BSPs, in different noise ranges, limits the effectiveness of the forward solution. Phase biomarkers are sensitive to the AEGs' pre-processing strategy. The BPF around HDF showed the best agreement between the different SNR levels. Due to the 3D morphological changes, HDF areas variability increased.","PeriodicalId":117840,"journal":{"name":"2022 Computing in Cardiology (CinC)","volume":"107 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Computing in Cardiology (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22489/CinC.2022.369","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Atrial fibrillation (AF) is a common supraventricular arrhythmia (SVA) in clinical practice and is characterized by uncoordinated electrical activity of the atria. This study aims to evaluate the influence on the forward solution of AF torso biomarkers under different levels of noise, 3D cardiorespiratory torso/atria morphologies, and number of atria electrodes. 2,048 atrial epicardium electrograms (AEGs) from 5 AF mathematical models were used to estimate 771 body surface potentials (BSPs). The BSPs and respective frequency/phase maps of are obtained after: (i) introduction of noise in the AEGs, (ii) 3D geometry torso/atria modification, and (iii) reduction in electrodes (from 2,048 to 256, 128, 64 e 32; interpolation methods: Linear/Laplacian). To reduce biomarkers disparity, a Butterworth bandpass filter (BPF) at different cut-off frequencies (0.5-30, 3–30 and HDF±1 Hz) is applied on the AEGs prior BSPs estimation. The above methodology is extended to two AF patients (EDGAR database). The estimation of AF BSPs, in different noise ranges, limits the effectiveness of the forward solution. Phase biomarkers are sensitive to the AEGs' pre-processing strategy. The BPF around HDF showed the best agreement between the different SNR levels. Due to the 3D morphological changes, HDF areas variability increased.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
从心房信号中估计躯干电位的定制方法的验证:一项计算临床研究
心房颤动(AF)是临床上常见的室上性心律失常(SVA),其特点是心房电活动不协调。本研究旨在评估不同水平的噪声、三维心肺躯干/心房形态和心房电极数量对房颤躯干生物标志物正向溶液的影响。利用5个AF数学模型的2,048张心房心外膜电图(aeg)估计771个体表电位(BSPs)。bsp和各自的频率/相位图是在以下情况下获得的:(i)在aeg中引入噪声,(ii) 3D几何躯干/心房修改,以及(iii)减少电极(从2,048减少到256、128、64 e 32;插值方法:线性/拉普拉斯)。为了减少生物标志物的差异,在不同的截止频率(0.5- 30,3 -30和HDF±1hz)下应用巴特沃斯带通滤波器(BPF)对aaegs先验BSPs估计。上述方法扩展到2例房颤患者(EDGAR数据库)。在不同噪声范围下对自动对焦BSPs的估计限制了正演解的有效性。相生物标志物对aeg的预处理策略敏感。HDF附近的BPF在不同信噪比水平之间表现出最好的一致性。由于三维形态的变化,HDF面积变异性增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Nonlinear Dynamic Response of Intrapartum Fetal Heart Rate to Uterine Pressure Heart Pulse Demodulation from Emfit Mattress Sensor Using Spectral and Source Separation Techniques Automated Algorithm for QRS Detection in Cardiac Arrest Patients with PEA Extraction Algorithm for Morphologically Preserved Non-Invasive Multi-Channel Fetal ECG Improved Pulse Pressure Estimation Based on Imaging Photoplethysmographic Signals
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1