Experimental study and CMFD modeling of transport processes in flow of two Immiscible liquids

M. Arshad, I. R. Chughtai, M. H. Inayat, A. Haq
{"title":"Experimental study and CMFD modeling of transport processes in flow of two Immiscible liquids","authors":"M. Arshad, I. R. Chughtai, M. H. Inayat, A. Haq","doi":"10.1109/IBCAST.2013.6512160","DOIUrl":null,"url":null,"abstract":"Rectangular shaped sieve plate column was installed for study of transport parameters through high speed photography and image analysis. Two Immiscible liquids consisting of the dispersed phase (water) and continuous phase (kerosene oil) were introduced in countercurrent operation. Experiments were performed for dispersed and continuous phase superficial velocities 0.16-0.44 cm/sec and 0.37-0.47 cm/sec respectively, pulsation frequency 0.95 -1.72 rev/sec and pulsation amplitude 1cm. Upon increasing the superficial velocity of dispersed phase, its void fraction increases up to its asymptotic value and droplet velocity increase while the droplet size decreases. Upon increasing the pulsation frequency, its void fraction increases while the droplet size and droplet velocity decreases. A Computational Multi Fluid Dynamics simulation has been carried out in order to verify the experimental results using the FLUENT. The CMFD calculations for void fraction have been compared with the experimental results which have shown a maximum deviation of 2-3%.","PeriodicalId":276834,"journal":{"name":"Proceedings of 2013 10th International Bhurban Conference on Applied Sciences & Technology (IBCAST)","volume":"115 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 2013 10th International Bhurban Conference on Applied Sciences & Technology (IBCAST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IBCAST.2013.6512160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Rectangular shaped sieve plate column was installed for study of transport parameters through high speed photography and image analysis. Two Immiscible liquids consisting of the dispersed phase (water) and continuous phase (kerosene oil) were introduced in countercurrent operation. Experiments were performed for dispersed and continuous phase superficial velocities 0.16-0.44 cm/sec and 0.37-0.47 cm/sec respectively, pulsation frequency 0.95 -1.72 rev/sec and pulsation amplitude 1cm. Upon increasing the superficial velocity of dispersed phase, its void fraction increases up to its asymptotic value and droplet velocity increase while the droplet size decreases. Upon increasing the pulsation frequency, its void fraction increases while the droplet size and droplet velocity decreases. A Computational Multi Fluid Dynamics simulation has been carried out in order to verify the experimental results using the FLUENT. The CMFD calculations for void fraction have been compared with the experimental results which have shown a maximum deviation of 2-3%.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
两种不混相液体流动输运过程的实验研究与CMFD建模
安装矩形筛板柱,通过高速摄影和图像分析研究输送参数。逆流操作中引入了分散相(水)和连续相(煤油)两种不混相液体。脉动频率为0.95 ~ 1.72 rev/sec,脉动幅值为1cm,分散相表面速度为0.16 ~ 0.44 cm/sec,连续相表面速度为0.37 ~ 0.47 cm/sec。随着分散相表面速度的增加,其空隙率逐渐增大,直至其渐近值,液滴速度增大,液滴尺寸减小。随着脉动频率的增加,其空隙率增加,液滴尺寸和液滴速度减小。为了验证实验结果,利用FLUENT进行了计算多流体动力学仿真。将CMFD计算结果与实验结果进行了比较,结果显示最大偏差为2-3%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Linear independent increment process with linear standard deviation function for degradation analysis Sensor fault reconstruction for one-sided Lipschitz nonlinear systems Colloidal preparation of copper selenide and indium selenide nanoparticles by single source precursors approach Novel iris segmentation and recognition system for human identification A narrowband low noise amplifier for passive imaging systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1