Microbiological contamination of the inner surface of finished water filling taps at bottled drinking water producers in Khanh Hoa province

Phong Le Quoc
{"title":"Microbiological contamination of the inner surface of finished water filling taps at bottled drinking water producers in Khanh Hoa province","authors":"Phong Le Quoc","doi":"10.47866/2615-9252/vjfc.4119","DOIUrl":null,"url":null,"abstract":"The finished water filling tap is the final contact point of filtered drinking water before bottling. Therefore, microbial contamination at this site may result in cross-contamination into the finished water in the bottle. This study was conducted to evaluate microbiological contamination on the inner surface of the finished water filling tap at the bottled drinking water producers in Khanh Hoa in 2022. A total of 93 swab samples of the inside surface of the tap at 93 producers were subjected to a test for ATP (Adenosine Triphosphate), total plate count (TPC), coliform, Escherichia coli, Pseudomonas aeruginosa, Streptococci feacal, and Clostridia. There were 72/93 (77.4%) samples with ATP values higher than 300 RLU/cm2. The geometric mean of ATP and TPC were 3.1±0.8 log (RLU/cm2) and 3.5±1.2 log (CFU/cm2), respectively. The ATP and TPC were linear correlated, indicating that the surface ATP value inside the finished water filling tap was mainly formed by microorganisms. In addition, 6/93 (6.5%) samples were found to be positive for coliform, including 3 strains of Enterobacter cloacae, 2 strains of Klebsiella pneumoniae and 1 strain of Enterobacter aerogenes. Moreover, 1/93 (1.1%) samples were infected with P. aeruginosa. All 7 strains of these bacteria were biofilm producers under laboratory conditions. Our results demonstrated that the cleaning and decontamination of finished water filling taps were not properly processed, thereby increasing the risk of microbial contamination into finished bottled water.","PeriodicalId":498772,"journal":{"name":"Tạp chí Kiểm nghiệm và An toàn thực phẩm","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tạp chí Kiểm nghiệm và An toàn thực phẩm","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47866/2615-9252/vjfc.4119","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The finished water filling tap is the final contact point of filtered drinking water before bottling. Therefore, microbial contamination at this site may result in cross-contamination into the finished water in the bottle. This study was conducted to evaluate microbiological contamination on the inner surface of the finished water filling tap at the bottled drinking water producers in Khanh Hoa in 2022. A total of 93 swab samples of the inside surface of the tap at 93 producers were subjected to a test for ATP (Adenosine Triphosphate), total plate count (TPC), coliform, Escherichia coli, Pseudomonas aeruginosa, Streptococci feacal, and Clostridia. There were 72/93 (77.4%) samples with ATP values higher than 300 RLU/cm2. The geometric mean of ATP and TPC were 3.1±0.8 log (RLU/cm2) and 3.5±1.2 log (CFU/cm2), respectively. The ATP and TPC were linear correlated, indicating that the surface ATP value inside the finished water filling tap was mainly formed by microorganisms. In addition, 6/93 (6.5%) samples were found to be positive for coliform, including 3 strains of Enterobacter cloacae, 2 strains of Klebsiella pneumoniae and 1 strain of Enterobacter aerogenes. Moreover, 1/93 (1.1%) samples were infected with P. aeruginosa. All 7 strains of these bacteria were biofilm producers under laboratory conditions. Our results demonstrated that the cleaning and decontamination of finished water filling taps were not properly processed, thereby increasing the risk of microbial contamination into finished bottled water.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
庆化省瓶装饮用水生产商成品充水龙头内表面的微生物污染
成品充水龙头是装瓶前过滤饮用水的最后接触点。因此,在这个地方的微生物污染可能导致交叉污染进入瓶中的成品水。本研究旨在评估2022年庆化省瓶装饮用水生产商成品充水龙头内表面的微生物污染情况。对93家生产商的水龙头内表面的93个棉签样本进行了ATP(三磷酸腺苷)、总平板计数(TPC)、大肠菌群、大肠杆菌、铜绿假单胞菌、粪便链球菌和梭状芽胞杆菌的检测。有72/93(77.4%)样品的ATP值高于300 RLU/cm2。ATP和TPC的几何平均值分别为3.1±0.8 log (RLU/cm2)和3.5±1.2 log (CFU/cm2)。ATP与TPC呈线性相关,说明成品充水龙头内部的表面ATP值主要由微生物形成。大肠菌群检出6/93株(6.5%),其中阴沟肠杆菌3株、肺炎克雷伯菌2株、产气肠杆菌1株。此外,1/93(1.1%)的样品感染了铜绿假单胞菌。在实验室条件下,这7株细菌都能产生生物膜。我们的研究结果表明,成品瓶装水的清洁和净化处理不当,从而增加了成品瓶装水被微生物污染的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Knowledge and practice on the use of alcohol and coffee among final-year undergraduate students of Hanoi Medical University in 2023 Initial research on the application of the liquid chromatography - quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) method for monitoring pesticide residues in fruits and vegetables Simultaneous determination of crocin and crocetin in food samples by highperformance liquid chromatography (HPLC-PDA) Microbiological contamination of the inner surface of finished water filling taps at bottled drinking water producers in Khanh Hoa province A mini-review on analytical methods for polycyclic aromatic hydrocarbons in Vietnamese food and beverage samples
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1