Straightness of Central Anatomical Axes of Human Tibia-Fibula System: Role of Fibula and Its Importance in Biomechanics

Ashish Tiwari, Pankaj Wahi, Shakti S Gupta, Niraj Sinha
{"title":"Straightness of Central Anatomical Axes of Human Tibia-Fibula System: Role of Fibula and Its Importance in Biomechanics","authors":"Ashish Tiwari, Pankaj Wahi, Shakti S Gupta, Niraj Sinha","doi":"10.1115/1.4063649","DOIUrl":null,"url":null,"abstract":"Abstract Fracture may occur in human lower leg bones considering varying loads acting on them while performing various functions. Implants, commonly used in healing the fractures, must be properly aligned with the bones' anatomical axes for their proper functioning. While attempts to establish tibial anatomical axis have been made previously, combined central anatomical axis of human tibia and fibula remains unexplored. In this study, profiles of individual and combined central anatomical axes of tibia and fibula have been obtained using computed tomography (CT). These profiles are found to be approximately straight with the deviation from straight line for the centroidal axis of the combined system being approximately half of that for the tibia. It is further utilised in assessing the role of fibula in determining the critical stresses in the tibia with the help of static finite element analysis (FEA) of a tibia-fibula model. Even though fibula takes a smaller proportion of the total axial load, its absence increases the compressive stresses in the tibia due to increased bending moments at the critical cross-sections. Furthermore, FEA has been carried out to understand the clinical significance of the mismatch in the centroidal axis of an implant and its parent bone taking the example of the human tibia alone. FEA suggests that these central anatomical axes are in fact the load bearing axes of the bones and any misalignment of implant with the central anatomical axis may lead to patient discomfort and premature failure of the implant.","PeriodicalId":73734,"journal":{"name":"Journal of engineering and science in medical diagnostics and therapy","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of engineering and science in medical diagnostics and therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4063649","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Fracture may occur in human lower leg bones considering varying loads acting on them while performing various functions. Implants, commonly used in healing the fractures, must be properly aligned with the bones' anatomical axes for their proper functioning. While attempts to establish tibial anatomical axis have been made previously, combined central anatomical axis of human tibia and fibula remains unexplored. In this study, profiles of individual and combined central anatomical axes of tibia and fibula have been obtained using computed tomography (CT). These profiles are found to be approximately straight with the deviation from straight line for the centroidal axis of the combined system being approximately half of that for the tibia. It is further utilised in assessing the role of fibula in determining the critical stresses in the tibia with the help of static finite element analysis (FEA) of a tibia-fibula model. Even though fibula takes a smaller proportion of the total axial load, its absence increases the compressive stresses in the tibia due to increased bending moments at the critical cross-sections. Furthermore, FEA has been carried out to understand the clinical significance of the mismatch in the centroidal axis of an implant and its parent bone taking the example of the human tibia alone. FEA suggests that these central anatomical axes are in fact the load bearing axes of the bones and any misalignment of implant with the central anatomical axis may lead to patient discomfort and premature failure of the implant.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人体胫腓骨系统中心解剖轴的直线性:腓骨的作用及其在生物力学中的重要性
摘要:人类小腿在执行各种功能时,由于受到不同载荷的作用,可能会发生骨折。通常用于愈合骨折的植入物必须与骨骼的解剖轴正确对齐,以使其正常工作。虽然以前曾尝试建立胫骨解剖轴,但尚未探索人类胫骨和腓骨的联合中央解剖轴。在这项研究中,使用计算机断层扫描(CT)获得了胫骨和腓骨的单个和联合中央解剖轴的轮廓。这些轮廓近似为直线,组合系统的质心轴与直线的偏差约为胫骨的一半。在胫骨-腓骨模型的静态有限元分析(FEA)的帮助下,它进一步用于评估腓骨在确定胫骨临界应力中的作用。尽管腓骨在总轴向载荷中所占的比例较小,但由于临界截面弯矩增加,腓骨的缺失增加了胫骨的压应力。此外,以单独的人类胫骨为例,进行了有限元分析以了解植入物和其母骨的质心轴不匹配的临床意义。有限元分析表明,这些中心解剖轴实际上是骨骼的承重轴,种植体与中心解剖轴的任何错位都可能导致患者不适和种植体过早失效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
High-Speed Three-Dimensional-Digital Image Correlation and Schlieren Imaging Integrated With Shock Tube Loading for Investigating Dynamic Response of Human Tympanic Membrane Exposed to Blasts. Quantifying the Fascicular Changes in Recovered Achilles Tendon Patients Using Diffusion Magnetic Resonance Imaging and Tractography. Assistive Technology for Real-Time Fall Prevention during Walking: Evaluation of the Effect of an Intelligent Foot Orthosis A Simple Poc Device for Temperature Control of Multiple Reactions During Recombinase Polymerase Amplification Auxetic Structure Inspired Microneedle Arrays for Minimally Invasive Drug Delivery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1