K. Yamasaki, K. Okuda, J. Kono, A. Saito, D. Mori, R. Suzuki, Y. Kambara, R. Hamada, S. Namba, K. Tomita, Y. Pan, N. Tamura, C. Suzuki, H. Okuno
{"title":"Development of the Thomson scattering measurement system for cascade arc device with indirectly heated hollow cathode","authors":"K. Yamasaki, K. Okuda, J. Kono, A. Saito, D. Mori, R. Suzuki, Y. Kambara, R. Hamada, S. Namba, K. Tomita, Y. Pan, N. Tamura, C. Suzuki, H. Okuno","doi":"10.1088/1748-0221/18/11/c11007","DOIUrl":null,"url":null,"abstract":"Abstract We have developed a Thomson scattering measurement system for the cascade arc discharge device designed for the plasma window (PW) application study. The PW is one of the plasma application techniques that sustain the steep pressure gradient between high pressure (10–100 kPa) and a vacuum environment due to the thermal energy of the plasma. Since the plasma thermal energy is the essential parameter for the pressure separation capability of PW, we installed the Thomson scattering measurement system to observe the electron density and temperature within the anode and cathode of the PW for the detailed analysis of the pressure separation capability. The frequency-doubled Nd:YAG laser (532 nm, 200 mJ, 8 ns) was employed for the probe laser. The scattered light was fed to the triple grating spectrometer. The notch filter between the first and second grating eliminated the stray light, realizing a sufficiently high signal-to-noise ratio. The Thomson scattering measurement system successfully obtained the electron density and temperature of the cascade arc plasma at 20 mm downstream from the tip of the cathode. The installed system successfully obtained the Thomson scattering spectrum and showed that the electron density increased from 2 × 10 19 m -3 to 7 × 10 19 m -3 with the discharge power, while the electron temperature was almost constant at about 2 eV. The obtained data successfully contributed to the study of the pressure separation capability of the PW.","PeriodicalId":16184,"journal":{"name":"Journal of Instrumentation","volume":"28 1","pages":"0"},"PeriodicalIF":1.3000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1748-0221/18/11/c11007","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract We have developed a Thomson scattering measurement system for the cascade arc discharge device designed for the plasma window (PW) application study. The PW is one of the plasma application techniques that sustain the steep pressure gradient between high pressure (10–100 kPa) and a vacuum environment due to the thermal energy of the plasma. Since the plasma thermal energy is the essential parameter for the pressure separation capability of PW, we installed the Thomson scattering measurement system to observe the electron density and temperature within the anode and cathode of the PW for the detailed analysis of the pressure separation capability. The frequency-doubled Nd:YAG laser (532 nm, 200 mJ, 8 ns) was employed for the probe laser. The scattered light was fed to the triple grating spectrometer. The notch filter between the first and second grating eliminated the stray light, realizing a sufficiently high signal-to-noise ratio. The Thomson scattering measurement system successfully obtained the electron density and temperature of the cascade arc plasma at 20 mm downstream from the tip of the cathode. The installed system successfully obtained the Thomson scattering spectrum and showed that the electron density increased from 2 × 10 19 m -3 to 7 × 10 19 m -3 with the discharge power, while the electron temperature was almost constant at about 2 eV. The obtained data successfully contributed to the study of the pressure separation capability of the PW.
期刊介绍:
Journal of Instrumentation (JINST) covers major areas related to concepts and instrumentation in detector physics, accelerator science and associated experimental methods and techniques, theory, modelling and simulations. The main subject areas include.
-Accelerators: concepts, modelling, simulations and sources-
Instrumentation and hardware for accelerators: particles, synchrotron radiation, neutrons-
Detector physics: concepts, processes, methods, modelling and simulations-
Detectors, apparatus and methods for particle, astroparticle, nuclear, atomic, and molecular physics-
Instrumentation and methods for plasma research-
Methods and apparatus for astronomy and astrophysics-
Detectors, methods and apparatus for biomedical applications, life sciences and material research-
Instrumentation and techniques for medical imaging, diagnostics and therapy-
Instrumentation and techniques for dosimetry, monitoring and radiation damage-
Detectors, instrumentation and methods for non-destructive tests (NDT)-
Detector readout concepts, electronics and data acquisition methods-
Algorithms, software and data reduction methods-
Materials and associated technologies, etc.-
Engineering and technical issues.
JINST also includes a section dedicated to technical reports and instrumentation theses.