Design Analysis of Mid IR DIAL System for Detection of Hazardous Chemical Species

Pub Date : 2023-11-01 DOI:10.14429/dsj.73.18829
M K Jindal, Mainuddin ., S Veerabuthiran, Atul Kumar
{"title":"Design Analysis of Mid IR DIAL System for Detection of Hazardous Chemical Species","authors":"M K Jindal, Mainuddin ., S Veerabuthiran, Atul Kumar","doi":"10.14429/dsj.73.18829","DOIUrl":null,"url":null,"abstract":"Nowadays, both military and public agencies are concerned with the remote detection of toxic gases and chemical warfare agents in the atmosphere. A promising method for the remote detection of such harmful chemicals in the atmosphere is Differential Absorption Lidar (DIAL). In the current paper, system design analysis has been carried out to build a DIAL system for the detection of toxic chemical warfare agents, chemical warfare simulants, explosive precursors, and pollutants. The proposed DIAL system comprises an Optical Parametric Oscillator (OPO) based tuneable laser, a 203 mm diameter Cassegrain telescope, a TE-cooled MCT detector, suitable data acquisition hardware, etc. The DIAL output parameters like return signals, SNR, and minimum measurable concentrations have been simulated under different weather conditions such as clear sky, moderately hazy sky, and hazy atmospheric conditions for given system input parameters (pulse energy, detectivity, bandwidth, DAQ resolution, etc.). We have considered chemicals such as Sarin, Thiodiglycol (TDG), acetone, and methane to be detected using the system. Analysis has been carried out for these chemicals present at different locations with varying concentrations. Our analysis reveals that the DIAL system with a laser transmitter of 5 mJ energy and 203 mm receiver telescope is capable of detecting a few ppm concentrations of toxic chemicals present anywhere between the ranges from a few tens of meters to 2 km with topographic target present. The sensitivity of the system in terms of minimum detectable concentrations for the considered chemicals is also estimated for different atmospheric conditions. It is seen that the minimum detectable concentration of TDG is 3.2 ppm in clear weather conditions which increases to 9.2 ppm under a hazy atmosphere. A similar analysis has been carried out for other toxic chemicals and has been discussed in the paper.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14429/dsj.73.18829","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Nowadays, both military and public agencies are concerned with the remote detection of toxic gases and chemical warfare agents in the atmosphere. A promising method for the remote detection of such harmful chemicals in the atmosphere is Differential Absorption Lidar (DIAL). In the current paper, system design analysis has been carried out to build a DIAL system for the detection of toxic chemical warfare agents, chemical warfare simulants, explosive precursors, and pollutants. The proposed DIAL system comprises an Optical Parametric Oscillator (OPO) based tuneable laser, a 203 mm diameter Cassegrain telescope, a TE-cooled MCT detector, suitable data acquisition hardware, etc. The DIAL output parameters like return signals, SNR, and minimum measurable concentrations have been simulated under different weather conditions such as clear sky, moderately hazy sky, and hazy atmospheric conditions for given system input parameters (pulse energy, detectivity, bandwidth, DAQ resolution, etc.). We have considered chemicals such as Sarin, Thiodiglycol (TDG), acetone, and methane to be detected using the system. Analysis has been carried out for these chemicals present at different locations with varying concentrations. Our analysis reveals that the DIAL system with a laser transmitter of 5 mJ energy and 203 mm receiver telescope is capable of detecting a few ppm concentrations of toxic chemicals present anywhere between the ranges from a few tens of meters to 2 km with topographic target present. The sensitivity of the system in terms of minimum detectable concentrations for the considered chemicals is also estimated for different atmospheric conditions. It is seen that the minimum detectable concentration of TDG is 3.2 ppm in clear weather conditions which increases to 9.2 ppm under a hazy atmosphere. A similar analysis has been carried out for other toxic chemicals and has been discussed in the paper.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
危险化学物质中红外DIAL检测系统的设计分析
如今,军事和公共机构都在关注大气中有毒气体和化学战剂的远程探测。差分吸收激光雷达(DIAL)是远程探测大气中有害化学物质的一种很有前途的方法。本文进行了系统设计分析,构建了一个用于有毒化学战剂、化学战模拟物、爆炸性前体和污染物检测的DIAL系统。所提出的DIAL系统包括基于光学参量振荡器(OPO)的可调谐激光器、直径203 mm的卡塞格伦望远镜、te冷却MCT探测器和合适的数据采集硬件等。对于给定的系统输入参数(脉冲能量、探测率、带宽、DAQ分辨率等),在不同的天气条件下,如晴朗的天空、中度雾霾的天空和雾霾的大气条件下,模拟了DIAL输出参数,如返回信号、信噪比和最小可测量浓度。我们考虑使用该系统检测沙林、硫二甘醇(TDG)、丙酮和甲烷等化学物质。对这些化学物质在不同地点以不同浓度进行了分析。我们的分析表明,具有5兆焦耳能量的激光发射器和203毫米接收望远镜的DIAL系统能够检测到从几十米到2公里范围内存在的有毒化学物质的几ppm浓度,并且存在地形目标。在不同的大气条件下,还估计了该系统对所考虑的化学物质的最低可检测浓度的灵敏度。可以看出,在晴朗的天气条件下,TDG的最低检测浓度为3.2 ppm,在雾霾大气下增加到9.2 ppm。对其他有毒化学品也进行了类似的分析,并在本文中进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1