Silicon Carbide Timepix3 detector for quantum-imaging detection and spectral tracking of charged particles in wide range of energy and field-of-view

IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION Journal of Instrumentation Pub Date : 2023-11-01 DOI:10.1088/1748-0221/18/11/c11004
A. Novak, C. Granja, A. Sagatova, J. Jakubek, B. Zatko, V. Vondracek, M. Andrlik, V. Zach, S. Polansky, A. Rathi, C. Oancea
{"title":"Silicon Carbide Timepix3 detector for quantum-imaging detection and spectral tracking of charged particles in wide range of energy and field-of-view","authors":"A. Novak, C. Granja, A. Sagatova, J. Jakubek, B. Zatko, V. Vondracek, M. Andrlik, V. Zach, S. Polansky, A. Rathi, C. Oancea","doi":"10.1088/1748-0221/18/11/c11004","DOIUrl":null,"url":null,"abstract":"Abstract The hybrid architecture of the Timepix (TPX) family of detectors enables the use of different semiconductor sensors, most commonly silicon (Si), as well as high-density materials such as Cadmium Telluride (CdTe) or Gallium Arsenide (GaAs). For this purpose, we explore the potential of a silicon carbide (SiC) sensor bump-bonded on a Timepix3 detector as a radiation imaging and particle tracking detector. SiC stands as a radiation-hard material also with the ability to operate at elevated temperatures up to several hundreds of degrees Celsius. As a result, this sensor material is more suitable for radiation harsh environments compared to conventional e.g., Si sensors. In this work, we evaluate the response for precise radiation spectrometry and high-resolution particle tracking of newly developed SiC Timepix3 detector which is built and operated as a compact radiation camera MiniPIX-Timepix3 with integrated readout electronics. Calibration measurements were conducted with mono-energetic proton beams with energies of 13, 22, and 31 MeV at the U-120M cyclotron at the Nuclear Physics Institute Czech Academy of Science (NPI CAS), Prague, as well as 100 and 226 MeV at the Proton Therapy Center Czech (PTC) in Prague. High-resolution pattern recognition analysis and single-particle spectral tracking are used for detailed inspection and understanding of the sensor response. Results include distributions of deposited energy and linear energy transfer (LET) spectra. The spatial uniformity of the pixelated detector response is examined in terms of homogeneously distributed deposited energy.","PeriodicalId":16184,"journal":{"name":"Journal of Instrumentation","volume":"304 1-4","pages":"0"},"PeriodicalIF":1.3000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1748-0221/18/11/c11004","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract The hybrid architecture of the Timepix (TPX) family of detectors enables the use of different semiconductor sensors, most commonly silicon (Si), as well as high-density materials such as Cadmium Telluride (CdTe) or Gallium Arsenide (GaAs). For this purpose, we explore the potential of a silicon carbide (SiC) sensor bump-bonded on a Timepix3 detector as a radiation imaging and particle tracking detector. SiC stands as a radiation-hard material also with the ability to operate at elevated temperatures up to several hundreds of degrees Celsius. As a result, this sensor material is more suitable for radiation harsh environments compared to conventional e.g., Si sensors. In this work, we evaluate the response for precise radiation spectrometry and high-resolution particle tracking of newly developed SiC Timepix3 detector which is built and operated as a compact radiation camera MiniPIX-Timepix3 with integrated readout electronics. Calibration measurements were conducted with mono-energetic proton beams with energies of 13, 22, and 31 MeV at the U-120M cyclotron at the Nuclear Physics Institute Czech Academy of Science (NPI CAS), Prague, as well as 100 and 226 MeV at the Proton Therapy Center Czech (PTC) in Prague. High-resolution pattern recognition analysis and single-particle spectral tracking are used for detailed inspection and understanding of the sensor response. Results include distributions of deposited energy and linear energy transfer (LET) spectra. The spatial uniformity of the pixelated detector response is examined in terms of homogeneously distributed deposited energy.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
碳化硅Timepix3探测器,用于大范围能量和视场的带电粒子的量子成像探测和光谱跟踪
Timepix (TPX)探测器家族的混合架构允许使用不同的半导体传感器,最常见的是硅(Si),以及高密度材料,如碲化镉(CdTe)或砷化镓(GaAs)。为此,我们探索了在Timepix3探测器上粘合碳化硅(SiC)传感器作为辐射成像和粒子跟踪探测器的潜力。碳化硅作为一种抗辐射材料,也具有在高达几百摄氏度的高温下工作的能力。因此,与传统的硅传感器相比,这种传感器材料更适合辐射恶劣的环境。在这项工作中,我们评估了新开发的SiC Timepix3探测器对精确辐射光谱和高分辨率粒子跟踪的响应,该探测器是作为集成了读数电子器件的紧凑型辐射相机MiniPIX-Timepix3构建和运行的。在布拉格捷克科学院核物理研究所(NPI CAS)的U-120M回旋加速器和布拉格捷克质子治疗中心(PTC)的100和226 MeV的单能质子束上进行了校准测量,能量分别为13,22和31 MeV。高分辨率模式识别分析和单粒子光谱跟踪用于传感器响应的详细检查和理解。结果包括沉积能量和线性能量传递(LET)谱的分布。利用均匀分布的沉积能量考察了像素化探测器响应的空间均匀性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Instrumentation
Journal of Instrumentation 工程技术-仪器仪表
CiteScore
2.40
自引率
15.40%
发文量
827
审稿时长
7.5 months
期刊介绍: Journal of Instrumentation (JINST) covers major areas related to concepts and instrumentation in detector physics, accelerator science and associated experimental methods and techniques, theory, modelling and simulations. The main subject areas include. -Accelerators: concepts, modelling, simulations and sources- Instrumentation and hardware for accelerators: particles, synchrotron radiation, neutrons- Detector physics: concepts, processes, methods, modelling and simulations- Detectors, apparatus and methods for particle, astroparticle, nuclear, atomic, and molecular physics- Instrumentation and methods for plasma research- Methods and apparatus for astronomy and astrophysics- Detectors, methods and apparatus for biomedical applications, life sciences and material research- Instrumentation and techniques for medical imaging, diagnostics and therapy- Instrumentation and techniques for dosimetry, monitoring and radiation damage- Detectors, instrumentation and methods for non-destructive tests (NDT)- Detector readout concepts, electronics and data acquisition methods- Algorithms, software and data reduction methods- Materials and associated technologies, etc.- Engineering and technical issues. JINST also includes a section dedicated to technical reports and instrumentation theses.
期刊最新文献
High-speed readout system of X-ray CMOS image sensor for time domain astronomy Recent advances in combined Positron Emission Tomography and Magnetic Resonance Imaging Characterization of organic glass scintillator bars and their potential for a hybrid neutron/gamma ray imaging system for proton radiotherapy range verification Data analysis methods and applications of the eddy current diagnostic system in the Keda Torus eXperiment device Tracking a moving point source using triple gamma imaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1