In vivo Volumetric, DTI and 1H MRS Rat Brain Protocol for Monitoring Early Neurodegeneration and Efficacy of the Used Therapy

IF 1 4区 工程技术 Q4 INSTRUMENTS & INSTRUMENTATION Measurement Science Review Pub Date : 2023-10-01 DOI:10.2478/msr-2023-0030
Tomáš Tvrdík, Ľubomír Melicherčík, Katarína Šebeková, Jakub Szabó, Marianna Maková, Daniel Gogola, Svatava Kašparová
{"title":"<i>In vivo</i> Volumetric, DTI and <sup>1</sup>H MRS Rat Brain Protocol for Monitoring Early Neurodegeneration and Efficacy of the Used Therapy","authors":"Tomáš Tvrdík, Ľubomír Melicherčík, Katarína Šebeková, Jakub Szabó, Marianna Maková, Daniel Gogola, Svatava Kašparová","doi":"10.2478/msr-2023-0030","DOIUrl":null,"url":null,"abstract":"Abstract The aim of our study was to develop a multimodal experimental protocol for in vivo imaging and metabolic parameters (MRI, DTI and 1 H MRS) in an animal model of neurodegeneration. We have successfully developed the protocol for simultaneous DTI/MRI/ 1 H MRS measurement to ensure unaltered conditions for repeatable non-invasive experiments. In this experiment, diffusion tensor imaging, spectroscopic and volumetric “bio-markers” were generated in the brain for the D-galactose model of “age-related dementia”. The hippocampal relative volume, taurine and myo-inositol relative concentrations were found to be significant predictors contributing to the differences between the groups of rats treated with D-galactose in simulated “neurodegeneration”, even in response to the applied Huperzine A therapy.","PeriodicalId":49848,"journal":{"name":"Measurement Science Review","volume":"45 1","pages":"0"},"PeriodicalIF":1.0000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement Science Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/msr-2023-0030","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract The aim of our study was to develop a multimodal experimental protocol for in vivo imaging and metabolic parameters (MRI, DTI and 1 H MRS) in an animal model of neurodegeneration. We have successfully developed the protocol for simultaneous DTI/MRI/ 1 H MRS measurement to ensure unaltered conditions for repeatable non-invasive experiments. In this experiment, diffusion tensor imaging, spectroscopic and volumetric “bio-markers” were generated in the brain for the D-galactose model of “age-related dementia”. The hippocampal relative volume, taurine and myo-inositol relative concentrations were found to be significant predictors contributing to the differences between the groups of rats treated with D-galactose in simulated “neurodegeneration”, even in response to the applied Huperzine A therapy.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
体内容积法、DTI和1H MRS监测早期神经退行性变的大鼠脑方案及其治疗效果
摘要:本研究的目的是为神经变性动物模型的体内成像和代谢参数(MRI, DTI和1h MRS)制定一种多模态实验方案。我们已经成功开发了同时进行DTI/MRI/ 1 H MRS测量的方案,以确保可重复的非侵入性实验的不变条件。本实验对d -半乳糖“年龄相关性痴呆”模型进行脑内弥散张量成像、光谱和体积“生物标志物”生成。海马相对体积、牛磺酸和肌醇相对浓度被发现是导致d -半乳糖治疗组大鼠在模拟“神经变性”中的差异的重要预测因素,即使是对应用石杉碱A治疗的反应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Measurement Science Review
Measurement Science Review INSTRUMENTS & INSTRUMENTATION-
CiteScore
2.00
自引率
11.10%
发文量
37
审稿时长
4.8 months
期刊介绍: - theory of measurement - mathematical processing of measured data - measurement uncertainty minimisation - statistical methods in data evaluation and modelling - measurement as an interdisciplinary activity - measurement science in education - medical imaging methods, image processing - biosignal measurement, processing and analysis - model based biomeasurements - neural networks in biomeasurement - telemeasurement in biomedicine - measurement in nanomedicine - measurement of basic physical quantities - magnetic and electric fields measurements - measurement of geometrical and mechanical quantities - optical measuring methods - electromagnetic compatibility - measurement in material science
期刊最新文献
Accurate Solution of Adjustment Models of 3D Control Network Metamaterial Inspired Stub-Incorporated Quad-Band Diamond Shaped Monopole Antenna for Satellite and Wireless Application Influence of the Electrical Test Setup on the Voltage Gain Measurement of an Unloaded Rosen-Type Piezoelectric Transformer Vibrating in the First Three Modes ECG Arrhythmia Measurement and Classification for Portable Monitoring Adaptive Proportional Derivative Control for Magnetic Bearing in Full Maglev Left Ventricular Assist Device
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1