Investigation on Microstructure and Compressive Strength of Brazing Porous Nickel to Copper and Stainless Steel

IF 1.1 Q3 METALLURGY & METALLURGICAL ENGINEERING Acta Metallurgica Slovaca Pub Date : 2023-09-25 DOI:10.36547/ams.29.3.1863
Ramizah Rozaimay, Tuan Zaharinie Tuan Zahari, Yose Fachmi Buys, Poo Balan Ganesan, Zainul Huda, Tadashi Ariga
{"title":"Investigation on Microstructure and Compressive Strength of Brazing Porous Nickel to Copper and Stainless Steel","authors":"Ramizah Rozaimay, Tuan Zaharinie Tuan Zahari, Yose Fachmi Buys, Poo Balan Ganesan, Zainul Huda, Tadashi Ariga","doi":"10.36547/ams.29.3.1863","DOIUrl":null,"url":null,"abstract":"This paper investigates the effects of brazing temperatures on the microstructure and compressive strength for brazing porous nickel to copper and stainless steel using VZ2250 as the brazing filler metal. A high vacuum furnace is used to braze the samples. Three different brazing process parameters were set with a heating and cooling rate of 10°C/min, respectively. The characteristics of the joint interface have been investigated to evaluate the performance of the brazed samples by use of scanning electron microscope, energy-dispersive X-Ray spectroscope, X-Ray diffractometer, and Instron Universal Testing machine. The data obtained has been quantitively analyzed to confirm the diffusion of the BFM during the brazing process. It has been found that the diffusion process resulted in an increase in the rigidity of the porous Ni. The compressive strength tests for the brazed joint showed that the maximum compressive strength can be achieved for brazing at 680°C. The highest compressive strength value has been justified by quantitative analysis of the microstructural data. It has been proved that the VZ2250 BFM effectively diffused into the porous Ni at the brazing temperature of 680°C; Cu3P and Cu6Sn5 were detected at the brazed Interface 1, whereas MnNi3 phase at the brazed Interface 2.","PeriodicalId":44511,"journal":{"name":"Acta Metallurgica Slovaca","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Metallurgica Slovaca","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36547/ams.29.3.1863","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"METALLURGY & METALLURGICAL ENGINEERING","Score":null,"Total":0}
引用次数: 0

Abstract

This paper investigates the effects of brazing temperatures on the microstructure and compressive strength for brazing porous nickel to copper and stainless steel using VZ2250 as the brazing filler metal. A high vacuum furnace is used to braze the samples. Three different brazing process parameters were set with a heating and cooling rate of 10°C/min, respectively. The characteristics of the joint interface have been investigated to evaluate the performance of the brazed samples by use of scanning electron microscope, energy-dispersive X-Ray spectroscope, X-Ray diffractometer, and Instron Universal Testing machine. The data obtained has been quantitively analyzed to confirm the diffusion of the BFM during the brazing process. It has been found that the diffusion process resulted in an increase in the rigidity of the porous Ni. The compressive strength tests for the brazed joint showed that the maximum compressive strength can be achieved for brazing at 680°C. The highest compressive strength value has been justified by quantitative analysis of the microstructural data. It has been proved that the VZ2250 BFM effectively diffused into the porous Ni at the brazing temperature of 680°C; Cu3P and Cu6Sn5 were detected at the brazed Interface 1, whereas MnNi3 phase at the brazed Interface 2.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
多孔镍与铜及不锈钢钎焊的显微组织及抗压强度研究
以VZ2250为钎料,研究了钎焊温度对多孔镍与铜、不锈钢钎焊组织和抗压强度的影响。用高真空炉钎焊样品。设置3种不同的钎焊工艺参数,加热和冷却速度分别为10℃/min。采用扫描电子显微镜、能谱仪、x射线衍射仪和Instron万能试验机对钎焊试样的接头界面特征进行了研究,以评价钎焊试样的性能。对所获得的数据进行了定量分析,以证实BFM在钎焊过程中的扩散。结果表明,扩散过程使多孔Ni的硬度增加。钎焊接头抗压强度试验表明,在680℃时钎焊可达到最大抗压强度。通过显微组织数据的定量分析,确定了最高的抗压强度值。结果表明,在钎焊温度为680℃时,VZ2250 BFM能有效扩散到多孔Ni中;在钎焊界面1中检测到Cu3P和Cu6Sn5相,而在钎焊界面2中检测到MnNi3相。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Acta Metallurgica Slovaca
Acta Metallurgica Slovaca METALLURGY & METALLURGICAL ENGINEERING-
CiteScore
2.00
自引率
30.00%
发文量
22
审稿时长
12 weeks
期刊最新文献
PHYSICO-MECHANICAL PROPERTIES OF POLYMER MATRIX COMPOSITE MATERIAL REINFORCED WITH CARBONIZED CASSAVA BACK PEEL AND IRON FILLINGS EFFECT OF MIXING METHODS PRIOR THE DECOMPOSITION PROCESS ON THE DECOMPOSED FERRONICKEL SLAG WEAR AND ADHESION PROPERTIES OF MULTILAYER Ti/TiN ,(TiC)/TiCN/TaN THIN FILMS DEPOSITED ON Ti13Nb13Zr ALLOY BY CLOSE FIELD UNBALANCED MAGNETRON SPUTTERING Explicit and Implicit Integration of Constitutive Equations of Chaboche Isotropic-Kinematic Hardening Material Model INFLUENCE OF SINTERING TEMPERATURE ON THE STRUCTURAL OF Mg2Si0.3Sn0.7 ALLOY PREPARED BY POWDER METALLURGY
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1