A Study on the Sprinkler Installation Plan in the Air Conditioner Room through TRIZ Analysis

Hyun-Jung Lee, Jun-Seok Nam, Seung-Yun Kim
{"title":"A Study on the Sprinkler Installation Plan in the Air Conditioner Room through TRIZ Analysis","authors":"Hyun-Jung Lee, Jun-Seok Nam, Seung-Yun Kim","doi":"10.7731/kifse.15e23726","DOIUrl":null,"url":null,"abstract":"In the last five years, there have been a total of 1,168 fires in outdoor air conditioners, half of which 49.4% occurred in residential facilities. Since 2006, the “Regulations on Housing Construction Standards, etc.” have been revised, and the Air conditioner room that has entered the indoor space is operated without opening the louvers sufficiently in a small space, or dust and moisture accumulate in a poorly ventilated state due to loading a large amount of goods, and if the air conditioner is operated for a long time due to a heat waves, the outdoor unit overheats, increasing the risk of fire. The study investigated the cases of the sprinkler installation in the Air conditioner room by type, and analyzed the three causes of fire suppression failure of the sprinkler in the event of a fire: ignition source, combustible material, and head operation failure, and analyzed using TRIZ technique. In order not to fail to extinguish the fire, An additional head should be installed. Water radiated from Upper head cools the thermal part of Lower head when installed in combination with the Upper and lower head, and the Lower head does not work. When the upper head is operated, the lower head can also be operated, and the fire suppression effect was demonstrated through a fire test.","PeriodicalId":6687,"journal":{"name":"2019 9th International Conference on Fire Science and Fire Protection Engineering (ICFSFPE)","volume":"19 36","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 9th International Conference on Fire Science and Fire Protection Engineering (ICFSFPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7731/kifse.15e23726","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In the last five years, there have been a total of 1,168 fires in outdoor air conditioners, half of which 49.4% occurred in residential facilities. Since 2006, the “Regulations on Housing Construction Standards, etc.” have been revised, and the Air conditioner room that has entered the indoor space is operated without opening the louvers sufficiently in a small space, or dust and moisture accumulate in a poorly ventilated state due to loading a large amount of goods, and if the air conditioner is operated for a long time due to a heat waves, the outdoor unit overheats, increasing the risk of fire. The study investigated the cases of the sprinkler installation in the Air conditioner room by type, and analyzed the three causes of fire suppression failure of the sprinkler in the event of a fire: ignition source, combustible material, and head operation failure, and analyzed using TRIZ technique. In order not to fail to extinguish the fire, An additional head should be installed. Water radiated from Upper head cools the thermal part of Lower head when installed in combination with the Upper and lower head, and the Lower head does not work. When the upper head is operated, the lower head can also be operated, and the fire suppression effect was demonstrated through a fire test.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于TRIZ分析的空调房间洒水装置方案研究
在过去的5年里,室外空调共发生了1168起火灾,其中一半(49.4%)发生在住宅设施。2006年以来,《房屋建筑标准规定》等修订,进入室内空间的空调机房间在狭小空间内没有充分打开百叶,或因装载大量货物而在通风不良的状态下积聚灰尘和水分,如果空调因热浪而长时间运行,室外机过热,增加火灾风险。本研究通过对空调房间喷头安装案例的分类调查,分析了发生火灾时喷头灭火失败的三个原因:点火源、可燃物、喷头操作故障,并运用TRIZ技术进行了分析。为了灭火不失败,应该安装一个额外的喷头。当上下水头组合安装时,由上水头辐射出的水冷却下水头的热力部分,下水头不工作。操作上头部时,也可操作下头部,并通过火灾试验验证灭火效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Correlation Between the Infection Control Organizational Culture, Infection Control Fatigue, and Burnout A Study on the Sprinkler Installation Plan in the Air Conditioner Room through TRIZ Analysis Experimental Study on the Surface Pyrolysis Properties and Modeling of Expanded Polystyrene Experimental Study on a Fire Causedby Diesel Particulate Filter Regeneration Fire Characteristics of Lithium-ion Battery According to the State of Charge in an Accelerating Rate Calorimeter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1