Paulius Vestfal, Jurgita Černeckienė, Lina Šeduikytė
{"title":"Analysis of the Impact of High-Space Building Heating System Solutions on Building Energy Efficiency","authors":"Paulius Vestfal, Jurgita Černeckienė, Lina Šeduikytė","doi":"10.5755/j01.sace.33.2.34305","DOIUrl":null,"url":null,"abstract":"The existence of stratification in high-ceiling buildings is real, but not visible or easy noticeable by humans. For field measurements, the Prayer House – The Kaunas Basilica of the Resurrection of Christ, located in Kaunas, Lithuania, was chosen, in which the temperature distribution at different heights (6 m, 8 m, 10 m, 12 m, 14 m, 16 m and 18 m) during the heating season was observed. The Basilica had radiant heaters installed at 5 m height. According to the plan of the Prayer House, CFD model was created, and the temperature distribution of the different heating (radiant heating and floor heating) systems were compared. The IDA-ICE modelling of energy consumption was conducted using the CFD results as a basis, and the economic analysis was performed based on the obtained results. The study confirmed the existence of stratification in high-ceiling buildings.","PeriodicalId":36795,"journal":{"name":"Journal of Sustainable Architecture and Civil Engineering","volume":"60 6","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sustainable Architecture and Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5755/j01.sace.33.2.34305","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
The existence of stratification in high-ceiling buildings is real, but not visible or easy noticeable by humans. For field measurements, the Prayer House – The Kaunas Basilica of the Resurrection of Christ, located in Kaunas, Lithuania, was chosen, in which the temperature distribution at different heights (6 m, 8 m, 10 m, 12 m, 14 m, 16 m and 18 m) during the heating season was observed. The Basilica had radiant heaters installed at 5 m height. According to the plan of the Prayer House, CFD model was created, and the temperature distribution of the different heating (radiant heating and floor heating) systems were compared. The IDA-ICE modelling of energy consumption was conducted using the CFD results as a basis, and the economic analysis was performed based on the obtained results. The study confirmed the existence of stratification in high-ceiling buildings.