{"title":"Analysis on Fault Current Limiting Operations of Three-Phase Transformer Type SFCL Using Secondary Windings with Non-Isolation","authors":"Tae-Hee Han, Seok-Cheol Ko, Sung-Hun Lim","doi":"10.5207/jieie.2023.37.5.062","DOIUrl":null,"url":null,"abstract":"Three-phase transformer type superconducting fault current limiter(SFCL) using secondary windings with non-isolation, which consisted of three-phase transformer windings wound on three legs of E-I iron core and three superconducting modules(SCMs), were suggested and its fault current limiting operations according to ground-fault types were analyzed. To verify the effective operation of three-phase transformer type SFCL using secondary windings with non-isolation, the unsymmetrical ground and the symmetrical ground faults were applied into three-phase power simulated system with the suggested SFCL. From the analysis on the experiment, three-phase transformer type SFCL using secondary windings with non-isolation showed lower power burden of three SCMs compared to the SFCL using secondary winding with isolation, especially in case of an unsymmetrical ground fault occurrence.","PeriodicalId":488820,"journal":{"name":"Journal of The Korean Institute of Illuminating and Electrical Installation Engineers","volume":"79 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Korean Institute of Illuminating and Electrical Installation Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5207/jieie.2023.37.5.062","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Three-phase transformer type superconducting fault current limiter(SFCL) using secondary windings with non-isolation, which consisted of three-phase transformer windings wound on three legs of E-I iron core and three superconducting modules(SCMs), were suggested and its fault current limiting operations according to ground-fault types were analyzed. To verify the effective operation of three-phase transformer type SFCL using secondary windings with non-isolation, the unsymmetrical ground and the symmetrical ground faults were applied into three-phase power simulated system with the suggested SFCL. From the analysis on the experiment, three-phase transformer type SFCL using secondary windings with non-isolation showed lower power burden of three SCMs compared to the SFCL using secondary winding with isolation, especially in case of an unsymmetrical ground fault occurrence.