Flushing and locking management related to central venous catheter occlusion rate among adult patients in acute care: a best practice implementation project.

IF 2.7 4区 医学 Q2 HEALTH CARE SCIENCES & SERVICES Jbi Evidence Implementation Pub Date : 2024-05-01 DOI:10.1097/XEB.0000000000000394
Chia-Hao Fan, Chung-Ning Chu, Feng-Han Chiu, Chia-Te Chen, Heng-Hsin Tung
{"title":"Flushing and locking management related to central venous catheter occlusion rate among adult patients in acute care: a best practice implementation project.","authors":"Chia-Hao Fan, Chung-Ning Chu, Feng-Han Chiu, Chia-Te Chen, Heng-Hsin Tung","doi":"10.1097/XEB.0000000000000394","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction and objectives: </strong>A central venous catheter (CVC)-a type of central venous access device (CVAD)-is the most common intervention for critical illnesses. Obstruction of the CVC can lead to fatal consequences. Thus, it is critical to maintain catheter lumen patency. The CVC occlusion rate in a hospital in Taiwan was 33%. This project aimed to decrease the CVC occlusion rate in acute care.</p><p><strong>Methods: </strong>This project was conceptually informed by the JBI Evidence-Based Model of Healthcare, in particular, the conceptualization of evidence implementation as inclusive of context analysis, implementation, and evaluation of outcomes using evidence-based quality indicators. As part of the seven-phase implementation process, we used audit and feedback in a pre- and post-test design to measure baseline compliance. Based on the initial audit, we developed an implementation strategy responsive to the identified gaps in compliance. We then undertook a final audit to measure changes in compliance to evaluate our implementation effects. The JBI software, PACES, and the situational analysis software, GRiP, were used for data collection and implementation planning. There were six evidence-based criteria, with a sample size of 30 nurses for each criterion. The team carried out the project from September 2022 to January 2023.</p><p><strong>Results: </strong>Post-implementation audit compliance rates increased to 100% for the following criteria: the organization had a standardized flushing and locking solution protocol (0%), the CVAD lumen was locked upon completion of the final flush (10%), a single-dose system was used for flushing and locking the CVAD (60%), and preservative-free 0.9% sodium chloride was used to flush the CVAD (60%). Furthermore, the CVC occlusion rate decreased from 33% to 5%.</p><p><strong>Conclusions: </strong>The project successfully decreased the rate of CVC occlusion and increased the competence of nurses in acute care settings. The implementation of best practices in clinical care should focus on leadership, cross-department coordination, education, and innovation.</p>","PeriodicalId":48473,"journal":{"name":"Jbi Evidence Implementation","volume":" ","pages":"131-139"},"PeriodicalIF":2.7000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11107886/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jbi Evidence Implementation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/XEB.0000000000000394","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction and objectives: A central venous catheter (CVC)-a type of central venous access device (CVAD)-is the most common intervention for critical illnesses. Obstruction of the CVC can lead to fatal consequences. Thus, it is critical to maintain catheter lumen patency. The CVC occlusion rate in a hospital in Taiwan was 33%. This project aimed to decrease the CVC occlusion rate in acute care.

Methods: This project was conceptually informed by the JBI Evidence-Based Model of Healthcare, in particular, the conceptualization of evidence implementation as inclusive of context analysis, implementation, and evaluation of outcomes using evidence-based quality indicators. As part of the seven-phase implementation process, we used audit and feedback in a pre- and post-test design to measure baseline compliance. Based on the initial audit, we developed an implementation strategy responsive to the identified gaps in compliance. We then undertook a final audit to measure changes in compliance to evaluate our implementation effects. The JBI software, PACES, and the situational analysis software, GRiP, were used for data collection and implementation planning. There were six evidence-based criteria, with a sample size of 30 nurses for each criterion. The team carried out the project from September 2022 to January 2023.

Results: Post-implementation audit compliance rates increased to 100% for the following criteria: the organization had a standardized flushing and locking solution protocol (0%), the CVAD lumen was locked upon completion of the final flush (10%), a single-dose system was used for flushing and locking the CVAD (60%), and preservative-free 0.9% sodium chloride was used to flush the CVAD (60%). Furthermore, the CVC occlusion rate decreased from 33% to 5%.

Conclusions: The project successfully decreased the rate of CVC occlusion and increased the competence of nurses in acute care settings. The implementation of best practices in clinical care should focus on leadership, cross-department coordination, education, and innovation.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
冲洗和锁定管理与急诊成人患者中心静脉导管阻塞率相关:最佳实践实施项目
中心静脉导管(CVC)是一种中心静脉通路装置(CVAD),是危重疾病最常见的干预措施。CVC的阻塞会导致致命的后果。因此,保持导管管腔通畅至关重要。台湾某医院CVC闭塞率为33%。本项目旨在降低急性期CVC闭塞率。方法:本项目在概念上采用JBI循证医疗模型,特别是证据实施的概念,包括背景分析、实施和使用循证质量指标评估结果。作为七个阶段实现过程的一部分,我们在测试前和测试后设计中使用审计和反馈来度量基线遵从性。在初始审计的基础上,我们制定了一项实施策略,以应对已确定的合规差距。然后,我们进行了最后的审计,以衡量法规遵循方面的变化,以评估我们的实施效果。JBI软件pace和态势分析软件GRiP用于数据收集和实施计划。共有6个循证标准,每个标准的样本量为30名护士。该团队从2022年9月到2023年1月进行了该项目。结果:实施后审计的符合率提高到100%,符合以下标准:组织有标准化的冲洗和锁定溶液方案(0%),在最后一次冲洗完成后锁定CVAD管腔(10%),使用单剂量系统冲洗和锁定CVAD(60%),使用无防腐剂的0.9%氯化钠冲洗CVAD(60%)。CVC闭塞率由33%降至5%。结论:该项目成功地降低了CVC闭塞率,提高了急诊科护士的能力。临床护理最佳实践的实施应注重领导、跨部门协调、教育和创新。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.20
自引率
13.00%
发文量
23
期刊最新文献
Nutrition as therapy - the role of dietitian counseling: a best practice implementation project. Pain assessment and management in patients with dementia in Taiwan: a best practice implementation project. Comparison of two audit and feedback approaches: descriptive analysis of personal and contextual dynamics. Collaborative implementation science: a Can-SOLVE CKD case example. Improving communication among nursing staff at a children's hospital in the southern United States: a best practice implementation project.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1