Performance evaluation of a single microchannel plate with large length-to-diameter ratio

IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION Journal of Instrumentation Pub Date : 2023-12-01 DOI:10.1088/1748-0221/18/12/P12011
B. Yan, Shulin Liu, Binting Zhang, Huaxing Peng
{"title":"Performance evaluation of a single microchannel plate with large length-to-diameter ratio","authors":"B. Yan, Shulin Liu, Binting Zhang, Huaxing Peng","doi":"10.1088/1748-0221/18/12/P12011","DOIUrl":null,"url":null,"abstract":"The conventional microchannel plate (MCP) detector has found widespread application in various fields. This article focuses on investigating the performance of a single MCP with a large length-to-diameter ratio (L/D) of 80:1, particularly for single electron counting. To enhance MCP performance, alumina with a high secondary electron yield (SEY) is coated onto the MCP using atomic layer deposition (ALD). The SEYs of alumina thin films with different thicknesses are measured using a pulsing electron beam method. The 80:1 L/D MCPs operate in electron counting mode, and the optimal alumina thickness is determined through a comparative study of MCP performance before and after coating. The relationships between maximum SEY, primary electron energy, gain, peak-to-valley ratio (P/V), and pulse height resolution (PHR) are analyzed. After alumina coating, the single 80:1 MCP exhibits improved gain, P/V and PHR. The optimal P/V and PHR of a single MCP as functions of the primary electron energy align with the relationship between the SEY of the alumina coating and the primary electron energy. Additionally, the variation of DC gain with extracted charge is investigated. This article provides valuable insights for parameter selection in achieving the optimal working state of MCP and explores the potential application of single electron counting using a single MCP.","PeriodicalId":16184,"journal":{"name":"Journal of Instrumentation","volume":"165 2","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Instrumentation","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1748-0221/18/12/P12011","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

The conventional microchannel plate (MCP) detector has found widespread application in various fields. This article focuses on investigating the performance of a single MCP with a large length-to-diameter ratio (L/D) of 80:1, particularly for single electron counting. To enhance MCP performance, alumina with a high secondary electron yield (SEY) is coated onto the MCP using atomic layer deposition (ALD). The SEYs of alumina thin films with different thicknesses are measured using a pulsing electron beam method. The 80:1 L/D MCPs operate in electron counting mode, and the optimal alumina thickness is determined through a comparative study of MCP performance before and after coating. The relationships between maximum SEY, primary electron energy, gain, peak-to-valley ratio (P/V), and pulse height resolution (PHR) are analyzed. After alumina coating, the single 80:1 MCP exhibits improved gain, P/V and PHR. The optimal P/V and PHR of a single MCP as functions of the primary electron energy align with the relationship between the SEY of the alumina coating and the primary electron energy. Additionally, the variation of DC gain with extracted charge is investigated. This article provides valuable insights for parameter selection in achieving the optimal working state of MCP and explores the potential application of single electron counting using a single MCP.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
大长径比单微通道板的性能评估
传统的微通道板(MCP)探测器已广泛应用于各个领域。本文重点研究了长径比(L/D)为 80:1 的单个 MCP 的性能,尤其是在单电子计数方面。为了提高 MCP 的性能,利用原子层沉积(ALD)技术在 MCP 上镀上了具有高二次电子产率(SEY)的氧化铝。使用脉冲电子束法测量了不同厚度氧化铝薄膜的 SEY。长径比为 80:1 的 MCP 在电子计数模式下工作,通过对镀膜前后的 MCP 性能进行比较研究,确定了最佳氧化铝厚度。分析了最大 SEY、初级电子能量、增益、峰谷比 (P/V) 和脉冲高度分辨率 (PHR) 之间的关系。氧化铝镀膜后,单个 80:1 MCP 的增益、峰谷比和 PHR 均有所提高。单个 MCP 的最佳 P/V 和 PHR 与初级电子能量的函数关系与氧化铝涂层的 SEY 和初级电子能量之间的关系一致。此外,还研究了直流增益随提取电荷的变化。这篇文章为实现 MCP 最佳工作状态的参数选择提供了有价值的见解,并探索了使用单 MCP 进行单电子计数的潜在应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Instrumentation
Journal of Instrumentation 工程技术-仪器仪表
CiteScore
2.40
自引率
15.40%
发文量
827
审稿时长
7.5 months
期刊介绍: Journal of Instrumentation (JINST) covers major areas related to concepts and instrumentation in detector physics, accelerator science and associated experimental methods and techniques, theory, modelling and simulations. The main subject areas include. -Accelerators: concepts, modelling, simulations and sources- Instrumentation and hardware for accelerators: particles, synchrotron radiation, neutrons- Detector physics: concepts, processes, methods, modelling and simulations- Detectors, apparatus and methods for particle, astroparticle, nuclear, atomic, and molecular physics- Instrumentation and methods for plasma research- Methods and apparatus for astronomy and astrophysics- Detectors, methods and apparatus for biomedical applications, life sciences and material research- Instrumentation and techniques for medical imaging, diagnostics and therapy- Instrumentation and techniques for dosimetry, monitoring and radiation damage- Detectors, instrumentation and methods for non-destructive tests (NDT)- Detector readout concepts, electronics and data acquisition methods- Algorithms, software and data reduction methods- Materials and associated technologies, etc.- Engineering and technical issues. JINST also includes a section dedicated to technical reports and instrumentation theses.
期刊最新文献
High-speed readout system of X-ray CMOS image sensor for time domain astronomy Recent advances in combined Positron Emission Tomography and Magnetic Resonance Imaging Characterization of organic glass scintillator bars and their potential for a hybrid neutron/gamma ray imaging system for proton radiotherapy range verification Data analysis methods and applications of the eddy current diagnostic system in the Keda Torus eXperiment device Tracking a moving point source using triple gamma imaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1