Leadless Pacemaker Implantation in Patients With a Prior Conventional Pacing System

IF 2.5 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS CJC Open Pub Date : 2024-04-01 DOI:10.1016/j.cjco.2023.12.008
Julius Jelisejevas MD , François Regoli MD , Daniel Hofer MD , Giulio Conte MD , Tardu Oezkartal MD , Ardan M. Saguner MD , Maria Luce Caputo MD , Lorenzo Grazioli MD , Jan Steffel MD , Angelo Auricchio MD , Alexander Breitenstein MD
{"title":"Leadless Pacemaker Implantation in Patients With a Prior Conventional Pacing System","authors":"Julius Jelisejevas MD ,&nbsp;François Regoli MD ,&nbsp;Daniel Hofer MD ,&nbsp;Giulio Conte MD ,&nbsp;Tardu Oezkartal MD ,&nbsp;Ardan M. Saguner MD ,&nbsp;Maria Luce Caputo MD ,&nbsp;Lorenzo Grazioli MD ,&nbsp;Jan Steffel MD ,&nbsp;Angelo Auricchio MD ,&nbsp;Alexander Breitenstein MD","doi":"10.1016/j.cjco.2023.12.008","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Leadless pacing has been established as an alternative approach to transvenous devices for selected patients. Often, leadless pacemaker (LP) implantation is a de novo procedure, but in an increasing number of patients, an LP is used after previous implantation of a conventional pacing system (CPS).</p></div><div><h3>Methods</h3><p>A retrospective analysis was conducted of the efficacy and safety of LP implantation in the context of a previously implanted CPS, from 2 large Swiss centres.</p></div><div><h3>Results</h3><p>A total of 257 consecutive patients undergoing LP implantation were included. They were divided into 2 groups: group 1 consisted of 233 patients who did not have a previous CPS, and group 2 consisted of 24 patients with an in situ CPS. In group 2, a total of 20 patients (83%) required transvenous lead extraction due to infection, malfunction, or other reasons. In 3 patients with device-related infection, lead extraction and LP implantation was performed as a single procedure, whereas in the remaining 11 cases, a time window occurred between the 2 procedures (median: 11.5 days; range: 2-186 days). Electrical device parameters at implantation and during follow-up did not differ between the 2 groups (mean: 12.5 ± 9.3 months). Eight major periprocedural complications (3.1%) were encountered (4 pericardial effusions, 3 instances of femoral bleeding, and 1 instance of intra-abdominal bleeding) in the entire cohort within a 30-day period. No complications occurred in the group with a previous device. No infections were registered, even when complete extraction of an infected CPS was performed prior to LP implantation.</p></div><div><h3>Conclusions</h3><p>Implantation of an LP in patients with a prior CPS (with or without extraction of the previous system) was effective and safe in our population of patients.</p></div>","PeriodicalId":36924,"journal":{"name":"CJC Open","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2589790X23003761/pdfft?md5=37c2342807bf0ff6a30803e3048fa9b5&pid=1-s2.0-S2589790X23003761-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CJC Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2589790X23003761","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Leadless pacing has been established as an alternative approach to transvenous devices for selected patients. Often, leadless pacemaker (LP) implantation is a de novo procedure, but in an increasing number of patients, an LP is used after previous implantation of a conventional pacing system (CPS).

Methods

A retrospective analysis was conducted of the efficacy and safety of LP implantation in the context of a previously implanted CPS, from 2 large Swiss centres.

Results

A total of 257 consecutive patients undergoing LP implantation were included. They were divided into 2 groups: group 1 consisted of 233 patients who did not have a previous CPS, and group 2 consisted of 24 patients with an in situ CPS. In group 2, a total of 20 patients (83%) required transvenous lead extraction due to infection, malfunction, or other reasons. In 3 patients with device-related infection, lead extraction and LP implantation was performed as a single procedure, whereas in the remaining 11 cases, a time window occurred between the 2 procedures (median: 11.5 days; range: 2-186 days). Electrical device parameters at implantation and during follow-up did not differ between the 2 groups (mean: 12.5 ± 9.3 months). Eight major periprocedural complications (3.1%) were encountered (4 pericardial effusions, 3 instances of femoral bleeding, and 1 instance of intra-abdominal bleeding) in the entire cohort within a 30-day period. No complications occurred in the group with a previous device. No infections were registered, even when complete extraction of an infected CPS was performed prior to LP implantation.

Conclusions

Implantation of an LP in patients with a prior CPS (with or without extraction of the previous system) was effective and safe in our population of patients.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
为曾使用过传统起搏系统的患者植入无导线起搏器
背景无导线起搏已被确定为经静脉装置的替代方法,适用于特定患者。通常情况下,无导线起搏器(LP)植入术是一种全新的手术,但越来越多的患者在之前植入传统起搏系统(CPS)后使用 LP。方法 对瑞士两家大型中心在之前植入 CPS 的情况下植入 LP 的有效性和安全性进行了回顾性分析。他们被分为两组:第一组包括 233 名既往未植入 CPS 的患者,第二组包括 24 名原位植入 CPS 的患者。在第 2 组中,共有 20 名患者(83%)因感染、故障或其他原因需要拔除经静脉导联。在 3 例因装置感染的患者中,导联拔除和 LP 植入是作为单个手术进行的,而在其余 11 例患者中,2 个手术之间存在时间间隔(中位数:11.5 天;范围:2-186 天)。两组患者在植入时和随访期间的电子装置参数没有差异(平均:12.5 ± 9.3 个月)。整个组群在 30 天内出现了 8 例主要的围手术期并发症(3.1%)(4 例心包积液、3 例股动脉出血和 1 例腹腔内出血)。曾使用过设备的组员未出现并发症。结论在我们的患者群体中,为曾使用过 CPS 的患者植入 LP(无论是否拔除先前的系统)既有效又安全。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CJC Open
CJC Open Medicine-Cardiology and Cardiovascular Medicine
CiteScore
3.30
自引率
0.00%
发文量
143
审稿时长
60 days
期刊最新文献
Cardiac Papillary Fibroelastoma and Cerebrovascular Events: A Systematic Review Late-Onset Mitral Valve Prosthesis Dehiscence With Severe Paravalvular Leak—Infectious Versus Noninfectious Etiology Dilemma: A Case Report Assessing the Safety of Early Repatriation for Stable ST-Segment Elevation Myocardial Infarction Patients After Primary Percutaneous Coronary Intervention Coronary Sinus Reducer Improves Myocardial Perfusion in a Patient With Angina, Hypertrophic Cardiomyopathy, and Coronary Microvascular Disease Fractured and Entrapped Coronary Angioplasty Balloon Successfully Managed with Rotational Atherectomy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1