Determination of Sodium, Potassium, Calcium and Magnesium in Urine, Using Microwave Plasma - Atomic Emission Spectrometry and Multi-Energy Calibration

IF 1.1 4区 化学 Q3 CHEMISTRY, MULTIDISCIPLINARY Journal of the Mexican Chemical Society Pub Date : 2024-01-01 DOI:10.29356/jmcs.v68i1.1906
Tania Lizeth Espinoza Cruz, K. Wrobel, Eunice Yanez Barrientos, Alma Rosa Corrales Escobosa, M. Garay-Sevilla, Francisco Javier AcevedoAguilar, K. Wrobel
{"title":"Determination of Sodium, Potassium, Calcium and Magnesium in Urine, Using Microwave Plasma - Atomic Emission Spectrometry and Multi-Energy Calibration","authors":"Tania Lizeth Espinoza Cruz, K. Wrobel, Eunice Yanez Barrientos, Alma Rosa Corrales Escobosa, M. Garay-Sevilla, Francisco Javier AcevedoAguilar, K. Wrobel","doi":"10.29356/jmcs.v68i1.1906","DOIUrl":null,"url":null,"abstract":"Microwave plasma - atomic emission spectrometry with multi-energy calibration (MP-AES-MEC) was used for the determination of four major elements in urine. In the family of atomic emission spectrometry, the distinctive features of MP-AES are: (i) nitrogen-based toroidal-shape plasma; (ii) good plasma tolerance to total solids; (iii) exceptionally low operating cost. On the other hand, due to relatively low plasma temperature, this technique is susceptible to spectral interferences and sample-to-sample fluctuating baseline is typical limitation, if previous acid digestion is not performed. MEC is a non-conventional quantification method, not requiring baseline correction and it has been selected in this work to achieve reliable determination of Na, K, Ca and Mg in simply diluted urine. The principle underlying MEC is the proportionality between signal intensity and analyte concentration, occurring at any emission line for given element. Accordingly, for each sample, only two solutions were prepared likewise in the one-point standard addition and two analytical runs were performed, yet four experimental points were generated for calibration according with the number of emission lines utilized. Based on the results obtained by analyzing urines from different subjects, the sample dilution fold was selected to adjust the analyte concentration below half of the calibration range (150 for K, 200 for Na, 50 for Ca and 25 for Mg), while the addition of standard was done roughly doubling natural concentration in the diluted sample.  The evaluated instrumental limits of detection were: 0.009 ± 0.005 mg L-1 for K, 0.131 ± 0.011 mg L-1 for Na, 0.050 ± 0.014 mg L-1 for Ca and 0.059 ± 0.010 mg L-1 for Mg (five replicates in different days). Each analysis was performed in triplicate yielding percentage relative standard deviation £ 11 %. The percentage recoveries calculated taking the results obtained in acid-digested samples by external calibration as reference values were in the range: 83.3-102 % for K, 88.4-110 % for Na, 82.9-113 % for Ca and 85.8-108 % for Mg. The capability of the proposed MP-AES-MEC procedure for monitoring four elements in different clinical conditions was demonstrated by analyzing ten urines from diabetic patients and ten from non-diabetic control subjects; statistical differences between these two groups was found for Na and K.   Resumen. La espectrometría de emisión atómica con excitación en plasma de microondas y con el método de calibración multi-energéa (MP-AES-MEC) fueron empleados para la determinación de cuatro elementos mayoritarios en orina. Dentro de la familia de técnicas de espectrometría de emisión atómica, las características distintivas de MP-AES son las siguientes: (i) uso de plasma de nitrógeno con geometría toroidal; (ii) buena tolerancia del plasma a sólidos totales; (iii) excepcionalmente bajo costo de operación. Por otra parte, debido a la relativamente baja temperatura del plasma, una típica limitación de esta técnica es que es susceptible a interferencias espectrales y la fluctuación de línea base entre muestras si estas no son digeridas previamente. El método MEC es un método de cuantificación no-convencional, el cual no requiere corrección de linea base y fue seleccionado en este trabajo para lograr la determinación confiable de Na, K, Ca and Mg después de una simple dilución de orina. MEC se sustenta en la proporcionalidad entre intensidad de la señal y la concentración del analito existente en cualquier linea de emisión de un elemento dado. Para cada una de las muestras, se prepararon dos soluciones, igual que en el método de un punto de adición de estándar y se realizaron dos corridas analíticas, pero se generaron cuatro puntos experimentales para la calibración, correspondientes a cuatro líneas de emisión seleccionadas por elemento. Con base en los resultados obtenidos analizando orinas de diferentes sujetos, el factor de dilución de la muestra fue seleccionado para ajustar la concentración del analito por debajo de la mitad del rango de calibración (150 para K, 200 para Na, 50 para Ca, 25 para Mg), mientras que la adición de estándar se realizó subiendo aproximadamente al doble la concentración natural en la muestra diluida. Los límites de detección instrumentales fueron: 0.009 ± 0.005 mg L-1 para K, 0.131 ± 0.011 mg L-1 para Na, 0.050 ± 0.014 mg L-1 para Ca, 0.059 ± 0.010 mg L-1 para Mg (con base en cinco réplicas realizadas en diferentes días). Cada análisis se realizó por triplicado, obteniéndose valores de desviación estándar relativa £ 11 %. Los porcentajes de recuperación calculados considerando los resultados obtenidos en muestras digeridas con ácido mediante calibración externa convencional como valores de referencia fueron los siguientes: 83.3-102 % para K, 88.4-110 % para Na, 82.9-113 % para Ca, 85.8-108 % para Mg. La capacidad del procedimiento MP-AES-MEC para monitorear cuatro elementos en diferentes condiciones clínicas se demostró analizando orinas de pacientes diabéticos y orinas de sujetos en un grupo control, encontrándose diferencias estadísticamente significativas para Na y K.","PeriodicalId":17377,"journal":{"name":"Journal of the Mexican Chemical Society","volume":"113 9","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mexican Chemical Society","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.29356/jmcs.v68i1.1906","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Microwave plasma - atomic emission spectrometry with multi-energy calibration (MP-AES-MEC) was used for the determination of four major elements in urine. In the family of atomic emission spectrometry, the distinctive features of MP-AES are: (i) nitrogen-based toroidal-shape plasma; (ii) good plasma tolerance to total solids; (iii) exceptionally low operating cost. On the other hand, due to relatively low plasma temperature, this technique is susceptible to spectral interferences and sample-to-sample fluctuating baseline is typical limitation, if previous acid digestion is not performed. MEC is a non-conventional quantification method, not requiring baseline correction and it has been selected in this work to achieve reliable determination of Na, K, Ca and Mg in simply diluted urine. The principle underlying MEC is the proportionality between signal intensity and analyte concentration, occurring at any emission line for given element. Accordingly, for each sample, only two solutions were prepared likewise in the one-point standard addition and two analytical runs were performed, yet four experimental points were generated for calibration according with the number of emission lines utilized. Based on the results obtained by analyzing urines from different subjects, the sample dilution fold was selected to adjust the analyte concentration below half of the calibration range (150 for K, 200 for Na, 50 for Ca and 25 for Mg), while the addition of standard was done roughly doubling natural concentration in the diluted sample.  The evaluated instrumental limits of detection were: 0.009 ± 0.005 mg L-1 for K, 0.131 ± 0.011 mg L-1 for Na, 0.050 ± 0.014 mg L-1 for Ca and 0.059 ± 0.010 mg L-1 for Mg (five replicates in different days). Each analysis was performed in triplicate yielding percentage relative standard deviation £ 11 %. The percentage recoveries calculated taking the results obtained in acid-digested samples by external calibration as reference values were in the range: 83.3-102 % for K, 88.4-110 % for Na, 82.9-113 % for Ca and 85.8-108 % for Mg. The capability of the proposed MP-AES-MEC procedure for monitoring four elements in different clinical conditions was demonstrated by analyzing ten urines from diabetic patients and ten from non-diabetic control subjects; statistical differences between these two groups was found for Na and K.   Resumen. La espectrometría de emisión atómica con excitación en plasma de microondas y con el método de calibración multi-energéa (MP-AES-MEC) fueron empleados para la determinación de cuatro elementos mayoritarios en orina. Dentro de la familia de técnicas de espectrometría de emisión atómica, las características distintivas de MP-AES son las siguientes: (i) uso de plasma de nitrógeno con geometría toroidal; (ii) buena tolerancia del plasma a sólidos totales; (iii) excepcionalmente bajo costo de operación. Por otra parte, debido a la relativamente baja temperatura del plasma, una típica limitación de esta técnica es que es susceptible a interferencias espectrales y la fluctuación de línea base entre muestras si estas no son digeridas previamente. El método MEC es un método de cuantificación no-convencional, el cual no requiere corrección de linea base y fue seleccionado en este trabajo para lograr la determinación confiable de Na, K, Ca and Mg después de una simple dilución de orina. MEC se sustenta en la proporcionalidad entre intensidad de la señal y la concentración del analito existente en cualquier linea de emisión de un elemento dado. Para cada una de las muestras, se prepararon dos soluciones, igual que en el método de un punto de adición de estándar y se realizaron dos corridas analíticas, pero se generaron cuatro puntos experimentales para la calibración, correspondientes a cuatro líneas de emisión seleccionadas por elemento. Con base en los resultados obtenidos analizando orinas de diferentes sujetos, el factor de dilución de la muestra fue seleccionado para ajustar la concentración del analito por debajo de la mitad del rango de calibración (150 para K, 200 para Na, 50 para Ca, 25 para Mg), mientras que la adición de estándar se realizó subiendo aproximadamente al doble la concentración natural en la muestra diluida. Los límites de detección instrumentales fueron: 0.009 ± 0.005 mg L-1 para K, 0.131 ± 0.011 mg L-1 para Na, 0.050 ± 0.014 mg L-1 para Ca, 0.059 ± 0.010 mg L-1 para Mg (con base en cinco réplicas realizadas en diferentes días). Cada análisis se realizó por triplicado, obteniéndose valores de desviación estándar relativa £ 11 %. Los porcentajes de recuperación calculados considerando los resultados obtenidos en muestras digeridas con ácido mediante calibración externa convencional como valores de referencia fueron los siguientes: 83.3-102 % para K, 88.4-110 % para Na, 82.9-113 % para Ca, 85.8-108 % para Mg. La capacidad del procedimiento MP-AES-MEC para monitorear cuatro elementos en diferentes condiciones clínicas se demostró analizando orinas de pacientes diabéticos y orinas de sujetos en un grupo control, encontrándose diferencias estadísticamente significativas para Na y K.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用微波等离子体-原子发射光谱和多能量校准法测定尿液中的钠、钾、钙和镁
通过分析糖尿病患者的尿液和对照组受试者的尿液,证明了 MP-AES-MEC 程序监测不同临床条件下四种元素的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.00
自引率
0.00%
发文量
0
审稿时长
6-12 weeks
期刊介绍: The Journal of the Mexican Chemical Society (J. Mex. Chem. Soc.) is a scientific, blind, peer reviewed, and open access, free of charge publication that covers all areas of chemistry and its sub-disciplines (i.e. medicinal chemistry, natural products, electrochemistry, material science, computational chemistry, organic chemistry, bionirganic chemistry, etc). It is devoted to facilitating the worldwide advancement of our understanding of chemistry. It will primarily publish original contributions of research in all branches of the theory and practice of chemistry in its broadest context as well as critical reviews in active areas of chemical research where the author has published significant contribution. The J. Mex. Chem. Soc. is a quarterly publication which language of submission and publication is English. To be suitable for publication in J. Mex. Chem. Soc., manuscripts must describe novel aspects of chemistry, high quality of results and discussion an excellent bibliographic support, and contribute to the development of the field. Routine or incremental work are not suitable for publication in J. Mex. Chem. Soc. Authors are encouraged to send contributions in electronic form. Our online submission system guides you stepwise through the process of entering your article details and uploading your files.
期刊最新文献
Contribution of Dispersion to the Intrinsic Energy Barriers of Neutral Model Diels-Alder Reactions In Vitro and In Silico Studies of Bis-furyl-pyrrolo[3,4-b]pyridin-5-ones on Dengue Virus Microwave-Assisted Reactivity of a Fischer Alkynyl Carbene Complex with Benzylidene Anilines Synthesis, in vitro Antitrichomonal Activity, and Docking Study of N-[(4-substituted phenyl)-1,3-thiazol-2-yl]-4-substituted Benzenesulfonamides DFT and Molecular Docking Studies of Melatonin and Some Analogues Interaction with Xanthine Oxidase as a Possible Antiradical Mechanism
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1