A selective dispersive liquid-liquid micro-extraction technique for trace level pollutants enrichment of pharmaceutical residues from hospital wastewaters followed by liquid chromatographic analysis
Gadisa Wakuma, Estifanos Ele Yaya, Negash Getachew, Negussie Megersa
{"title":"A selective dispersive liquid-liquid micro-extraction technique for trace level pollutants enrichment of pharmaceutical residues from hospital wastewaters followed by liquid chromatographic analysis","authors":"Gadisa Wakuma, Estifanos Ele Yaya, Negash Getachew, Negussie Megersa","doi":"10.4314/bcse.v38i1.3","DOIUrl":null,"url":null,"abstract":"In this study a dispersive liquid-liquid micro-extraction (DLLME) method was utilized for extraction of trace pharmaceuticals in wastewater samples. Factors influencing the extraction performances were tested and accordingly 900 µL dichloroethane as the extraction solvent, 1400 µL acetonitirle as dispersive solvent, 10 min extraction time at 4000 rpm centrifugation, and pH 5 were found optimum. Acetonitrile and 0.2% formic acid in water were used as eluent. The column temperature was maintained at 25 °C and the optimum detection wavelengths of 273 nm for sulfamethoxazole and 280 nm for ciprofloxacin were used. For both the analytes, the coefficients of determinations (r2) were found to vary from 0.9989 to 0.9997, confirming good linearity in the concentration range of 0.005-100 µg mL-1 for sulfamethoxazole and 0.01-100 µg mL-1 for ciprofloxacin. The LOD and LOQ were in the range of 0.78-1.58 ng mL-1 and 2.24-5.28 ng mL-1, respectively; the RSDs were 0.41-3.21% for intra-day precision and 0.37-6.44% for inter-day precision. The concentrations of the three pharmaceuticals determined ranged from 0.76-1.53 μg mL-1 in the wastewater samples collected from Black Lion Hospital. However, ciprofloxacin and doxycycline were not detected and only low concentration of sulfamethoxazole was detected in the wastewater samples collected from Menelik II Hospital. KEY WORDS: Antibiotics, DLLME, Dispersive solvent, Hospital wastewater Bull. Chem. Soc. Ethiop. 2024, 38(1), 27-42. DOI: https://dx.doi.org/10.4314/bcse.v38i1.3","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.4314/bcse.v38i1.3","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
In this study a dispersive liquid-liquid micro-extraction (DLLME) method was utilized for extraction of trace pharmaceuticals in wastewater samples. Factors influencing the extraction performances were tested and accordingly 900 µL dichloroethane as the extraction solvent, 1400 µL acetonitirle as dispersive solvent, 10 min extraction time at 4000 rpm centrifugation, and pH 5 were found optimum. Acetonitrile and 0.2% formic acid in water were used as eluent. The column temperature was maintained at 25 °C and the optimum detection wavelengths of 273 nm for sulfamethoxazole and 280 nm for ciprofloxacin were used. For both the analytes, the coefficients of determinations (r2) were found to vary from 0.9989 to 0.9997, confirming good linearity in the concentration range of 0.005-100 µg mL-1 for sulfamethoxazole and 0.01-100 µg mL-1 for ciprofloxacin. The LOD and LOQ were in the range of 0.78-1.58 ng mL-1 and 2.24-5.28 ng mL-1, respectively; the RSDs were 0.41-3.21% for intra-day precision and 0.37-6.44% for inter-day precision. The concentrations of the three pharmaceuticals determined ranged from 0.76-1.53 μg mL-1 in the wastewater samples collected from Black Lion Hospital. However, ciprofloxacin and doxycycline were not detected and only low concentration of sulfamethoxazole was detected in the wastewater samples collected from Menelik II Hospital. KEY WORDS: Antibiotics, DLLME, Dispersive solvent, Hospital wastewater Bull. Chem. Soc. Ethiop. 2024, 38(1), 27-42. DOI: https://dx.doi.org/10.4314/bcse.v38i1.3
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.