{"title":"Radiation Dose Tracking in Digital Mammography: Evaluation of Population Profiles through Automatic Data Extraction from the DICOM Header","authors":"H. Schiabel, Eny Moreira Ruberti Filha, Oswaldo Jorge Neto, L. B. Verçosa","doi":"10.34257/ljmhrvol23is11pg1","DOIUrl":null,"url":null,"abstract":"International regulatory organizations for quality control of X-ray systems, such as the International Atomic Energy Agency (IAEA), have implemented protocols for acceptance testing of digital mammography and breast tomosynthesis equipment, aiming to establish quality standards in radiology services. However, these guidelines are usually based on tests with breast phantoms with standardizedthicknesses and compositions, often not representative of the patient population profiles at those services. In a prior study, we developed a computational system designed to automatically tracking and managing data extracted from the image acquisition processes of digital mammography and breast tomosynthesis, stored on a DICOM SCP (Service Class Provider) server. This approach enables obtaining technical reports characterizing exposure parameters and tests have shown that the reference levels outlined in international standards for breast composition and radiation dose do not accurately reflect the characteristics of the actual patient population. Thus this study describes data collection and corresponding analysis for the dose tracking process primarily on three digital mammography systems of different radiological services. Extensive image datasets from these systems were obtained using a new application described previously, with a focus on dose profiles generated during exposures. Graphical representations resultingfrom the datasets are presented, along with analysis of skin entrance and mean glandular doses distributions, average kV and mAs applied during the exams together with the target/filter combinations, radiographic density distribution, as well as the age and breast thickness characteristic of the respective population submitted to exposures in each of those mammography services. Additionally, the extent of information and ease of acquisition provided by the tool for performance evaluation of digital mammography services is discussed","PeriodicalId":93101,"journal":{"name":"Global journal of medical research","volume":"27 12","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global journal of medical research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34257/ljmhrvol23is11pg1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

International regulatory organizations for quality control of X-ray systems, such as the International Atomic Energy Agency (IAEA), have implemented protocols for acceptance testing of digital mammography and breast tomosynthesis equipment, aiming to establish quality standards in radiology services. However, these guidelines are usually based on tests with breast phantoms with standardizedthicknesses and compositions, often not representative of the patient population profiles at those services. In a prior study, we developed a computational system designed to automatically tracking and managing data extracted from the image acquisition processes of digital mammography and breast tomosynthesis, stored on a DICOM SCP (Service Class Provider) server. This approach enables obtaining technical reports characterizing exposure parameters and tests have shown that the reference levels outlined in international standards for breast composition and radiation dose do not accurately reflect the characteristics of the actual patient population. Thus this study describes data collection and corresponding analysis for the dose tracking process primarily on three digital mammography systems of different radiological services. Extensive image datasets from these systems were obtained using a new application described previously, with a focus on dose profiles generated during exposures. Graphical representations resultingfrom the datasets are presented, along with analysis of skin entrance and mean glandular doses distributions, average kV and mAs applied during the exams together with the target/filter combinations, radiographic density distribution, as well as the age and breast thickness characteristic of the respective population submitted to exposures in each of those mammography services. Additionally, the extent of information and ease of acquisition provided by the tool for performance evaluation of digital mammography services is discussed
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
数字乳腺 X 射线摄影中的辐射剂量跟踪:通过从 DICOM 标头自动提取数据评估人群概况
国际原子能机构(IAEA)等负责 X 射线系统质量控制的国际监管组织已经实施了数字乳腺 X 射线照相术和乳腺断层合成术设备验收测试协议,旨在建立放射服务的质量标准。然而,这些指南通常都是基于具有标准化厚度和成分的乳房模型进行测试,而这些模型通常并不能代表这些服务机构的病人群体特征。在之前的一项研究中,我们开发了一个计算系统,用于自动跟踪和管理从数字乳腺 X 射线照相术和乳腺断层合成术图像采集过程中提取的数据,这些数据存储在 DICOM SCP(服务类提供商)服务器上。测试表明,乳腺成分和辐射剂量国际标准中列出的参考水平并不能准确反映实际患者群体的特征。因此,本研究描述了主要针对不同放射服务机构的三台数字乳腺 X 射线摄影系统的剂量跟踪过程的数据收集和相应分析。这些系统的大量图像数据集是通过之前介绍过的一种新应用软件获取的,重点是曝光过程中产生的剂量曲线。数据集生成的图表展示了皮肤入口剂量和平均腺体剂量分布、检查期间使用的平均 kV 和 mAs 以及目标/滤波器组合、放射密度分布,以及每个乳腺 X 射线照相服务机构接受照射人群的年龄和乳房厚度特征。此外,还讨论了数字乳腺 X 射线照相服务性能评估工具所提供信息的范围和获取的难易程度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Gender Determination by Measuring the Mandibular Ramus and Body of the Mandible: A Retrospective Radiographic Study Hepatitis C Virus Infected Human Megakaryocytes and Platelets: Intra-and Extracellular Evaluation Preferential Induction of Canonical IMD and Toll Innate Immune Receptors by Bacterial Challenges in Triatoma Pallidipennis Primed with Gram-Negative and Gram-Positive Bacteria, Respectively PPIB Unveiled: A Comprehensive Pan-Cancer Exploration Unraveling Immunological Signatures and Prognostic Implications Self-Reported Cardiovascular Risk Factors among Medical Students
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1