Atık Demir Talaşlı Çimento Harçlarında Elektriksel İletkenliğin Araştırılması

Ahmet Fi̇lazi̇, Rustem Yi̇lmazel, Muharrem Pul
{"title":"Atık Demir Talaşlı Çimento Harçlarında Elektriksel İletkenliğin Araştırılması","authors":"Ahmet Fi̇lazi̇, Rustem Yi̇lmazel, Muharrem Pul","doi":"10.29137/umagd.1252097","DOIUrl":null,"url":null,"abstract":"In this study, the electrical conductivity of cement mortars formed by additive waste iron chip was investigated. Mixtures with fixed water/cement (0.5) ratios and different ratios of iron chip were prepared. Cement mortars were prepared by adding 0%, 1%, 2%, 4%, 8% and 16% by weight of cement in the mixtures and waste iron chip in the range of 0.5 mm to 4 mm in size. Firstly, the flow test was applied to the cement mortars cured in normal water for 7 and 28 days and their flexure and compressive strengths were determined. Then, the electrical conductivity test was applied to the cement mortar samples. As a result, it was observed that the flow diameter values increased as the average length increased from 0.5 mm to 2 mm in 1% and 2% additive of waste iron chip. It was determined that 1% waste iron chip was higher at 4.54% compressive strength compared to the reference sample. As the amount of added waste iron chip increased, the electrical resistivity value in the samples decreased and the electrical conductivity value increased along with it. At the same time, it was determined that the added iron chip size also increased the electrical conductivity.","PeriodicalId":23481,"journal":{"name":"Uluslararası Muhendislik Arastirma ve Gelistirme Dergisi","volume":"49 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Uluslararası Muhendislik Arastirma ve Gelistirme Dergisi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29137/umagd.1252097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, the electrical conductivity of cement mortars formed by additive waste iron chip was investigated. Mixtures with fixed water/cement (0.5) ratios and different ratios of iron chip were prepared. Cement mortars were prepared by adding 0%, 1%, 2%, 4%, 8% and 16% by weight of cement in the mixtures and waste iron chip in the range of 0.5 mm to 4 mm in size. Firstly, the flow test was applied to the cement mortars cured in normal water for 7 and 28 days and their flexure and compressive strengths were determined. Then, the electrical conductivity test was applied to the cement mortar samples. As a result, it was observed that the flow diameter values increased as the average length increased from 0.5 mm to 2 mm in 1% and 2% additive of waste iron chip. It was determined that 1% waste iron chip was higher at 4.54% compressive strength compared to the reference sample. As the amount of added waste iron chip increased, the electrical resistivity value in the samples decreased and the electrical conductivity value increased along with it. At the same time, it was determined that the added iron chip size also increased the electrical conductivity.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
废铁屑在水泥砂浆中的导电性研究
本研究调查了添加废铁屑形成的水泥砂浆的导电性。制备了固定水灰比(0.5)和不同铁屑比例的混合物。在混合物中添加 0%、1%、2%、4%、8% 和 16%(按水泥重量计)的水泥和 0.5 毫米至 4 毫米大小的废铁屑,制备水泥砂浆。首先,对在常水中固化 7 天和 28 天的水泥砂浆进行流动性测试,并测定其抗弯强度和抗压强度。然后,对水泥砂浆样品进行了导电性测试。结果发现,当平均长度从 0.5 毫米增加到 2 毫米时,1% 和 2%的废铁屑添加剂的流动直径值也随之增加。与参考样品相比,1% 的废铁屑抗压强度更高,为 4.54%。随着废铁屑添加量的增加,样品中的电阻率值降低,导电率值随之增加。同时,添加的铁屑尺寸也增加了导电率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Ticari Bir Pistonlu Motorda JP8-Elementel Bor Katkısının Performansa Etkisinin Deneysel İncelenmesi Behavior of reinforced concrete beams under different angled cold joints at shear zone Pim Disk Aşınma Test Cihazı Tasarımı ve İmalatı Hem İşletmeci Hem de Kullanıcı Açısından Kent İçi Otobüs Hatlarının Performanslarının Değerlendirilmesi Thermodynamic Analysis of Liquid Steel Production in an ElectricArc Furnace
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1