Assessing the Seismic Performance of Exterior Precast Concrete Joints with Ultra-High-Performance Fiber-Reinforced Concrete

IF 3.6 3区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY International Journal of Concrete Structures and Materials Pub Date : 2024-02-09 DOI:10.1186/s40069-023-00646-9
Seungki Kim, Jinwon Shin, Woosuk Kim
{"title":"Assessing the Seismic Performance of Exterior Precast Concrete Joints with Ultra-High-Performance Fiber-Reinforced Concrete","authors":"Seungki Kim, Jinwon Shin, Woosuk Kim","doi":"10.1186/s40069-023-00646-9","DOIUrl":null,"url":null,"abstract":"<p>This study was conducted to evaluate the seismic performance of an exterior precast concrete (PC) beam–column joint with ultra-high-performance fiber-reinforced concrete (UHPFRC). Currently, 45 MPa non-shrinkage mortar is used as grouting for the connection between PC beams and columns. In this study, PC joint specimens were designed using 45 MPa non-shrinkage mortar and 120 MPa UHPFRC as a grouting agent for connecting PC members. The shear reinforcement effect of UHPFRC was confirmed to reduce shear cracks in the joint core; this trend was similar in the specimens with reduced shear rebars. The maximum moment of the test specimen with the corbel was slightly increased, but there was no significant difference, and the failure pattern also showed similar results to the specimen without the corbel. In the test specimen to which the U-shaped beam was applied, the attachment surface of ultra-high-performance concrete and normal concrete were separated, and a large decrease in strength was observed. Considering workability, U-shaped beam do not seem to have any major merits in general, such as increased strength and difficulty in manufacturing, and it was judged that it was effective to separate the PC beams from the column face through corbels. Shear reinforcement through UHPFRC is effective in relieving congestion by reducing shear reinforcement bars at the joint, and it is judged that it can be used as PC joint grouting due to its excellent fluidity.</p>","PeriodicalId":13832,"journal":{"name":"International Journal of Concrete Structures and Materials","volume":"313 1","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2024-02-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Concrete Structures and Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1186/s40069-023-00646-9","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

This study was conducted to evaluate the seismic performance of an exterior precast concrete (PC) beam–column joint with ultra-high-performance fiber-reinforced concrete (UHPFRC). Currently, 45 MPa non-shrinkage mortar is used as grouting for the connection between PC beams and columns. In this study, PC joint specimens were designed using 45 MPa non-shrinkage mortar and 120 MPa UHPFRC as a grouting agent for connecting PC members. The shear reinforcement effect of UHPFRC was confirmed to reduce shear cracks in the joint core; this trend was similar in the specimens with reduced shear rebars. The maximum moment of the test specimen with the corbel was slightly increased, but there was no significant difference, and the failure pattern also showed similar results to the specimen without the corbel. In the test specimen to which the U-shaped beam was applied, the attachment surface of ultra-high-performance concrete and normal concrete were separated, and a large decrease in strength was observed. Considering workability, U-shaped beam do not seem to have any major merits in general, such as increased strength and difficulty in manufacturing, and it was judged that it was effective to separate the PC beams from the column face through corbels. Shear reinforcement through UHPFRC is effective in relieving congestion by reducing shear reinforcement bars at the joint, and it is judged that it can be used as PC joint grouting due to its excellent fluidity.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估使用超高性能纤维增强混凝土的室外预制混凝土接缝的抗震性能
本研究旨在评估采用超高性能纤维增强混凝土(UHPFRC)的外部预制混凝土(PC)梁柱连接的抗震性能。目前,PC 梁和柱之间的连接采用 45 兆帕无收缩砂浆作为灌浆材料。本研究设计了 PC 连接试件,使用 45 兆帕无收缩砂浆和 120 兆帕超高压纤维增强混凝土作为连接 PC 构件的灌浆剂。经证实,超高压纤维增强混凝土的抗剪加固效果可减少连接核心部位的剪切裂缝;这一趋势与减少抗剪钢筋的试件相似。带有边框的试件的最大弯矩略有增加,但没有明显差异,破坏模式也与没有边框的试件相似。在施加 U 形梁的试件中,超高性能混凝土与普通混凝土的附着面分离,强度大幅下降。考虑到可加工性,U 形梁总体上似乎并没有增加强度和制造难度等主要优点,因此判断通过连梁将 PC 梁与柱面分离是有效的。通过超高分子量纤维增强塑料混凝土进行剪力加固,可减少连接处的剪力加固杆,从而有效缓解拥挤状况,而且由于其流动性极佳,可以判断其可用作 PC 连接灌浆。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Concrete Structures and Materials
International Journal of Concrete Structures and Materials CONSTRUCTION & BUILDING TECHNOLOGY-ENGINEERING, CIVIL
CiteScore
6.30
自引率
5.90%
发文量
61
审稿时长
13 weeks
期刊介绍: The International Journal of Concrete Structures and Materials (IJCSM) provides a forum targeted for engineers and scientists around the globe to present and discuss various topics related to concrete, concrete structures and other applied materials incorporating cement cementitious binder, and polymer or fiber in conjunction with concrete. These forums give participants an opportunity to contribute their knowledge for the advancement of society. Topics include, but are not limited to, research results on Properties and performance of concrete and concrete structures Advanced and improved experimental techniques Latest modelling methods Possible improvement and enhancement of concrete properties Structural and microstructural characterization Concrete applications Fiber reinforced concrete technology Concrete waste management.
期刊最新文献
Experimental Investigation on Axial Strength Improvement of Cold-Formed Steel Jacketed Concrete Stub Columns Proposal of a Creep-Experiment Method and Superficial Creep Coefficient Model of CFT Considering a Stress-Redistribution Effect Impact of Rubber Content on Performance of Ultra-High-Performance Rubberised Concrete (UHPRuC) Study on the Diffusion Mechanism of Infiltration Grouting in Fault Fracture Zone Considering the Time-Varying Characteristics of Slurry Viscosity Under Seawater Environment Enhancing the Flexural Capacity of Deteriorated Low-Strength Prestressed Concrete Beam Using Near-Surface Mounted Post-Tensioned Carbon Fiber-Reinforced Polymer Bar
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1