{"title":"Subjective and objective image quality of low-dose CT images processed using a self-supervised denoising algorithm.","authors":"Yuya Kimura, Takeru Q Suyama, Yasuteru Shimamura, Jun Suzuki, Masato Watanabe, Hiroshi Igei, Yuya Otera, Takayuki Kaneko, Maho Suzukawa, Hirotoshi Matsui, Hiroyuki Kudo","doi":"10.1007/s12194-024-00786-x","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to assess the subjective and objective image quality of low-dose computed tomography (CT) images processed using a self-supervised denoising algorithm with deep learning. We trained the self-supervised denoising model using low-dose CT images of 40 patients and applied this model to CT images of another 30 patients. Image quality, in terms of noise and edge sharpness, was rated on a 5-point scale by two radiologists. The coefficient of variation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were calculated. The values for the self-supervised denoising model were compared with those for the original low-dose CT images and CT images processed using other conventional denoising algorithms (non-local means, block-matching and 3D filtering, and total variation minimization-based algorithms). The mean (standard deviation) scores of local and overall noise levels for the self-supervised denoising algorithm were 3.90 (0.40) and 3.93 (0.51), respectively, outperforming the original image and other algorithms. Similarly, the mean scores of local and overall edge sharpness for the self-supervised denoising algorithm were 3.90 (0.40) and 3.75 (0.47), respectively, surpassing the scores of the original image and other algorithms. The CNR and SNR for the self-supervised denoising algorithm were higher than those for the original images but slightly lower than those for the other algorithms. Our findings indicate the potential clinical applicability of the self-supervised denoising algorithm for low-dose CT images in clinical settings.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":" ","pages":"367-374"},"PeriodicalIF":1.7000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-024-00786-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
This study aimed to assess the subjective and objective image quality of low-dose computed tomography (CT) images processed using a self-supervised denoising algorithm with deep learning. We trained the self-supervised denoising model using low-dose CT images of 40 patients and applied this model to CT images of another 30 patients. Image quality, in terms of noise and edge sharpness, was rated on a 5-point scale by two radiologists. The coefficient of variation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were calculated. The values for the self-supervised denoising model were compared with those for the original low-dose CT images and CT images processed using other conventional denoising algorithms (non-local means, block-matching and 3D filtering, and total variation minimization-based algorithms). The mean (standard deviation) scores of local and overall noise levels for the self-supervised denoising algorithm were 3.90 (0.40) and 3.93 (0.51), respectively, outperforming the original image and other algorithms. Similarly, the mean scores of local and overall edge sharpness for the self-supervised denoising algorithm were 3.90 (0.40) and 3.75 (0.47), respectively, surpassing the scores of the original image and other algorithms. The CNR and SNR for the self-supervised denoising algorithm were higher than those for the original images but slightly lower than those for the other algorithms. Our findings indicate the potential clinical applicability of the self-supervised denoising algorithm for low-dose CT images in clinical settings.
期刊介绍:
The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.