{"title":"Assessment of Stability of Early Loaded Nano Coated Hydroxyapatite Implants in Posterior Maxilla","authors":"O. Amin, I. Shehata, H. Kamel, N. Elbokle","doi":"10.33696/nanotechnol.5.049","DOIUrl":null,"url":null,"abstract":"Aim: The aim of the study was to assess the stability after early loading of nano coated hydroxyapatite implants in posterior maxilla.\n\nMethodology: This study was conducted on nine patients with at least a missing one maxillary posterior tooth. Ten Nano-coated hydroxyapatite implants (ETIII NH implant by Hiossen) were inserted in nine patients, and then subjected to early loading according to the secondary stability readings taken by Osstell®. Implant stability was measured at the time of implant insertion (T0), 4 (T1), 6 (T1 modified), weeks, and 4 months (T2) post-operative. Cone-beam computed tomography (CBCT) was performed in all patients before starting the treatment. Nine implants healed well except for one implant that failed due to infection.\n\nResults: Secondary stability results after 6 weeks of implant incretion were sufficient enough for implant loading, there was significant difference (F= 12.642, DF 3, P value <0.001) among T0, T1, T1 modified, and T2. \n\nConclusion: Nano-coated hydroxyapatite implants are of good choice in posterior maxilla and they can be early loaded.","PeriodicalId":94095,"journal":{"name":"Journal of nanotechnology and nanomaterials","volume":"32 22","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of nanotechnology and nanomaterials","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.33696/nanotechnol.5.049","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Aim: The aim of the study was to assess the stability after early loading of nano coated hydroxyapatite implants in posterior maxilla.
Methodology: This study was conducted on nine patients with at least a missing one maxillary posterior tooth. Ten Nano-coated hydroxyapatite implants (ETIII NH implant by Hiossen) were inserted in nine patients, and then subjected to early loading according to the secondary stability readings taken by Osstell®. Implant stability was measured at the time of implant insertion (T0), 4 (T1), 6 (T1 modified), weeks, and 4 months (T2) post-operative. Cone-beam computed tomography (CBCT) was performed in all patients before starting the treatment. Nine implants healed well except for one implant that failed due to infection.
Results: Secondary stability results after 6 weeks of implant incretion were sufficient enough for implant loading, there was significant difference (F= 12.642, DF 3, P value <0.001) among T0, T1, T1 modified, and T2.
Conclusion: Nano-coated hydroxyapatite implants are of good choice in posterior maxilla and they can be early loaded.