the Determination and evaluation of trace elements in the blood of radiography workers using graphite furnace atomic absorption spectrometry

Ahmed Jaber Ibrahim
{"title":"the Determination and evaluation of trace elements in the blood of radiography workers using graphite furnace atomic absorption spectrometry","authors":"Ahmed Jaber Ibrahim","doi":"10.24200/amecj.v7.i01.321","DOIUrl":null,"url":null,"abstract":"This study aimed to evaluate the potentially toxic effects of trace elements in the blood of Iraqi medical radiography workers by analyzing them through GF-AAS. The study involved 50 male blood radiography workers from the medical imaging field at Al-Shatrah General Hospital in Thi-Qar City, Iraq. All workers were aged between 35-50 years and had worked for less than 10 years. The study compared these workers with 50 healthy men. The study found a significant increase in the levels of Cu, Pb, Cd, and Ca among radiography workers compared to the healthy control group, while Zn and Se levels decreased significantly. Moreover, Specificity and confidence interval (95%) were estimated via the receiver operating characteristic curve (ROC). The study provided conclusive evidence of disturbances in the levels of trace elements in the blood of radiographer workers, which makes them more susceptible to many diseases because of their radiation exposure. which portends the more preventive measures of radiation. The linear range of Cd, Cu, Zn, Se and Pb in human serum were obtained 0.2-6.0 µg dL-1, 6.0-200 µg dL-1, 8.0-200 µg dL-1, 10-250 µg dL-1, 4-120 µg dL-1 by GF-AAS after dilution samples with DW up to 20 (n=10, RSD< 5%).","PeriodicalId":7797,"journal":{"name":"Analytical Methods in Environmental Chemistry Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods in Environmental Chemistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24200/amecj.v7.i01.321","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to evaluate the potentially toxic effects of trace elements in the blood of Iraqi medical radiography workers by analyzing them through GF-AAS. The study involved 50 male blood radiography workers from the medical imaging field at Al-Shatrah General Hospital in Thi-Qar City, Iraq. All workers were aged between 35-50 years and had worked for less than 10 years. The study compared these workers with 50 healthy men. The study found a significant increase in the levels of Cu, Pb, Cd, and Ca among radiography workers compared to the healthy control group, while Zn and Se levels decreased significantly. Moreover, Specificity and confidence interval (95%) were estimated via the receiver operating characteristic curve (ROC). The study provided conclusive evidence of disturbances in the levels of trace elements in the blood of radiographer workers, which makes them more susceptible to many diseases because of their radiation exposure. which portends the more preventive measures of radiation. The linear range of Cd, Cu, Zn, Se and Pb in human serum were obtained 0.2-6.0 µg dL-1, 6.0-200 µg dL-1, 8.0-200 µg dL-1, 10-250 µg dL-1, 4-120 µg dL-1 by GF-AAS after dilution samples with DW up to 20 (n=10, RSD< 5%).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用石墨炉原子吸收光谱法测定和评估放射工作人员血液中的微量元素
本研究旨在通过 GF-AAS 分析法评估伊拉克医学放射摄影工作者血液中微量元素的潜在毒性影响。这项研究涉及 50 名来自伊拉克 Thi-Qar 市 Al-Shatrah 综合医院医学影像领域的男性血液放射摄影工作者。所有工人的年龄都在 35-50 岁之间,工作时间不到 10 年。研究将这些工人与 50 名健康男性进行了比较。研究发现,与健康对照组相比,放射工作人员体内铜、铅、镉和钙的含量明显增加,而锌和硒的含量则明显下降。此外,还通过接收器工作特征曲线(ROC)估算了特异性和置信区间(95%)。这项研究提供了确凿的证据,证明放射工作人员血液中的微量元素水平出现了紊乱,使他们更容易因暴露于辐射而患上多种疾病,这预示着需要采取更多的辐射预防措施。用 DW 稀释样本至 20(n=10,RSD< 5%)后,采用 GF-AAS 方法测定人体血清中的镉、铜、锌、硒和铅,其线性范围分别为 0.2-6.0 µg dL-1、6.0-200 µg dL-1、8.0-200 µg dL-1、10-250 µg dL-1、4-120 µg dL-1。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
0
期刊最新文献
Determine methylene blue based on carbon paste electrode modified with nanoparticles of nickel oxide-nitrogen carbon quantum dots and carbon structures by cyclic voltammetry A review: Exploratory analysis of recent advancement in green analytical chemistry application the Determination and evaluation of trace elements in the blood of radiography workers using graphite furnace atomic absorption spectrometry Chromium desalinization using novel chitosan functionalized iron oxide- biochar composites: Analysis, synthesis, characterization and adsorption performance Solid phase-fabrication of multi-walled carbon nanotubes and their derivatives for efficient extraction and analysis of Bismarck Brown-Y Dye from aqueous solution
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1