Evaluation of the ability to detect Bacillus cereus in food of chromogenic agar media RAPID’B.cereus according to ISO 7932:2004

Bich Vo Thi Nhu, Vu Truong Huynh Anh
{"title":"Evaluation of the ability to detect Bacillus cereus in food of chromogenic agar media RAPID’B.cereus according to ISO 7932:2004","authors":"Bich Vo Thi Nhu, Vu Truong Huynh Anh","doi":"10.47866/2615-9252/vjfc.4207","DOIUrl":null,"url":null,"abstract":"In this study, the ability to detect Bacillus cereus of the new chromogenic agar media RAPID’B.cereus (RBC) was compared with the standard selective culture media Mannitol Egg Yolk Polymyxin (MYP) recommended by food authorities for isolation, identification, and quantification of Bacillus cereus. Two types of media were used to conduct the assessment on five categories of food, including cereals and cereal products; flour and starch; vegetables and vegetable products; milk and dairy products; and confectionery (n = 164). The results of the survey Bacillus cereus contamination on RBC (75.61%), MYP (70.12%), of which 46.09% of the samples didn’t meet the standards of the Ministry of Health on the maximum allowable limit of Bacillus cereus in food. Conducting performance testing of RBC according to ISO 16140-2:2016 with parameters: growth, selectivity, specificity, relative trueness and accuracy profile, the analysis results all met the criteria according to the standard: the development (PR) of the two media were 0.97 and 0.81 respectively; a high level of background microflora was present on the MYP plates while if it was not the case on the RBC plates; both media allowed the detection of Bacillus cereus with a difference of 0.14.  Compared with the acceptance criteria as prescribed, the categories used in the study were all suitable for assessment in the new media with the accuracy between the two methods being equivalent.","PeriodicalId":12896,"journal":{"name":"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heavy metals and arsenic concentrations in water, agricultural soil, and rice in Ngan Son district, Bac Kan province, Vietnam","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47866/2615-9252/vjfc.4207","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, the ability to detect Bacillus cereus of the new chromogenic agar media RAPID’B.cereus (RBC) was compared with the standard selective culture media Mannitol Egg Yolk Polymyxin (MYP) recommended by food authorities for isolation, identification, and quantification of Bacillus cereus. Two types of media were used to conduct the assessment on five categories of food, including cereals and cereal products; flour and starch; vegetables and vegetable products; milk and dairy products; and confectionery (n = 164). The results of the survey Bacillus cereus contamination on RBC (75.61%), MYP (70.12%), of which 46.09% of the samples didn’t meet the standards of the Ministry of Health on the maximum allowable limit of Bacillus cereus in food. Conducting performance testing of RBC according to ISO 16140-2:2016 with parameters: growth, selectivity, specificity, relative trueness and accuracy profile, the analysis results all met the criteria according to the standard: the development (PR) of the two media were 0.97 and 0.81 respectively; a high level of background microflora was present on the MYP plates while if it was not the case on the RBC plates; both media allowed the detection of Bacillus cereus with a difference of 0.14.  Compared with the acceptance criteria as prescribed, the categories used in the study were all suitable for assessment in the new media with the accuracy between the two methods being equivalent.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
根据 ISO 7932:2004 评估使用 RAPID'B.cereus 发色琼脂培养基检测食品中蜡样芽孢杆菌的能力
本研究比较了新型发色琼脂培养基 RAPID'B.cereus(RBC)与标准选择性培养基甘露醇蛋黄多粘菌素(MYP)检测蜡样芽孢杆菌的能力,后者被食品当局推荐用于蜡样芽孢杆菌的分离、鉴定和定量。采用两种培养基对五类食品进行了评估,包括谷物和谷物制品、面粉和淀粉、蔬菜和蔬菜制品、奶和奶制品以及糖果(n = 164)。调查结果显示,蜡样芽孢杆菌污染了 RBC(75.61%)和 MYP(70.12%),其中 46.09% 的样品不符合卫生部关于食品中蜡样芽孢杆菌最高允许限量的标准。根据 ISO 16140-2:2016,对 RBC 进行了性能测试,测试参数包括生长性、选择性、特异性、相对真实度和准确性曲线,分析结果均符合标准要求:两种培养基的显影度(PR)分别为 0.97 和 0.81;MYP 平板上存在高水平的背景微生物菌群,而 RBC 平板上则没有;两种培养基均可检测到蜡样芽孢杆菌,差异为 0.14。 与规定的验收标准相比,研究中使用的类别都适合在新培养基中进行评估,两种方法的准确性相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Producing positive control materials for template in PCR testing to detect botulinum neurotoxin types A and B genes Food safety knowledge and practices of vegetarian food processors in Hanoi in 2022-2023 Research and development of non-enzymatic electrochemical sensors utilizing porous ZnO/graphene electrodes to determine xanthine Study on coffee husk treatment by microorganisms A comprehensive study on reference material of Imidacloprid in tomato matrix
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1