{"title":"Management of aortic valve insufficiency in patients with continuous-flow left ventricular assist device: a republication of the review published in Japanese Journal of Artificial Organs","authors":"Naoki Tadokoro, Kohei Tonai, Satoshi Kainuma, Naonori Kawamoto, Kota Suzuki, Masaya Hirayama, Satsuki Fukushima","doi":"10.1007/s10047-024-01439-x","DOIUrl":null,"url":null,"abstract":"<p>Since 2011, implantable ventricular assist devices have been a standard treatment for severe heart failure alongside heart transplantation in Japan. However, the limited availability of donors has led to a prolonged wait for transplants, now averaging 1719 days, intensifying the issue of aortic insufficiency in patients with continuous flow ventricular assist devices. These devices limit the opening of the aortic valve, leading to sustained closure and increased shear stress, which accelerates valve degradation. Risk factors for aortic insufficiency include having a smaller body surface area, being of advanced age, and the presence of mild aortic insufficiency prior to device implantation. In patients presenting with mild or moderate aortic regurgitation at the time of ventricular assist device implantation, interventions such as aortic valve repair or bioprosthetic valve replacement are performed with the aim of halting its progression. The choice of surgical procedure should be tailored to each patient’s individual condition. The management of de novo aortic insufficiency in patients with continuous flow ventricular assist devices remains challenging, with no clear consensus on when to intervene. Interventions for significant aortic insufficiency typically consider the patient’s symptoms and aortic insufficiency severity. De novo aortic insufficiency progression in continuous flow ventricular assist devices patients necessitates careful monitoring and intervention based on individual patient assessments and valve condition. This review was created based on a translation of the Japanese review written in the <i>Japanese Journal of Artificial Organs</i> in 2023 (Vol. 52, No. 1, pp. 77–80), with some modifications.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":"25 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-024-01439-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Since 2011, implantable ventricular assist devices have been a standard treatment for severe heart failure alongside heart transplantation in Japan. However, the limited availability of donors has led to a prolonged wait for transplants, now averaging 1719 days, intensifying the issue of aortic insufficiency in patients with continuous flow ventricular assist devices. These devices limit the opening of the aortic valve, leading to sustained closure and increased shear stress, which accelerates valve degradation. Risk factors for aortic insufficiency include having a smaller body surface area, being of advanced age, and the presence of mild aortic insufficiency prior to device implantation. In patients presenting with mild or moderate aortic regurgitation at the time of ventricular assist device implantation, interventions such as aortic valve repair or bioprosthetic valve replacement are performed with the aim of halting its progression. The choice of surgical procedure should be tailored to each patient’s individual condition. The management of de novo aortic insufficiency in patients with continuous flow ventricular assist devices remains challenging, with no clear consensus on when to intervene. Interventions for significant aortic insufficiency typically consider the patient’s symptoms and aortic insufficiency severity. De novo aortic insufficiency progression in continuous flow ventricular assist devices patients necessitates careful monitoring and intervention based on individual patient assessments and valve condition. This review was created based on a translation of the Japanese review written in the Japanese Journal of Artificial Organs in 2023 (Vol. 52, No. 1, pp. 77–80), with some modifications.
期刊介绍:
The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.