Experimental installation of a reference source of low currents for calibration of electrometers

S. V. Sherstobitov
{"title":"Experimental installation of a reference source of low currents for calibration of electrometers","authors":"S. V. Sherstobitov","doi":"10.32446/0368-1025it.2024-3-38-44","DOIUrl":null,"url":null,"abstract":"Today, there is great scientific interest in the possibility of implementing reference sources of low currents based on single-electron pumps using the single-electron tunneling effect and the modern definition of the SI system. However, the practical use of this effect in everyday metrological practice has not yet reached the stage of widespread use. Typically, for routine calibration work in laboratories, either mass-produced instruments (low current sources and meters, electrometers) are used, which are calibrated against higher standards, or specially designed precision current sources. The article describes a reference installation developed on the basis of the VNIIFTRI, where in the mode of generating ultralow currents the principle of forming a linearly increasing voltage on a reference capacitor is used. A simplified block diagram of the reference setup is shown. Issues of practical adjustment of modern electrometers are considered. The generalized results of participation in international comparisons on low currents EURAMET.EM-S44 “Comparison of ultra-low DC current sources” conducted by national metrological institutes in 2018–2020 are presented. The results of a metrological study of the calibration factor Q and an example of calculating the uncertainty budget of measurements carried out at the VNIIFTRI as part of these international comparisons are presented. The research described in the article to increase the accuracy of measurements of small and ultra-low currents of this level has valuable practical significance in the field of electrical measurements, in aeroionometry and metrology of ionizing radiation.","PeriodicalId":14651,"journal":{"name":"Izmeritel`naya Tekhnika","volume":"39 20","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Izmeritel`naya Tekhnika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32446/0368-1025it.2024-3-38-44","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Today, there is great scientific interest in the possibility of implementing reference sources of low currents based on single-electron pumps using the single-electron tunneling effect and the modern definition of the SI system. However, the practical use of this effect in everyday metrological practice has not yet reached the stage of widespread use. Typically, for routine calibration work in laboratories, either mass-produced instruments (low current sources and meters, electrometers) are used, which are calibrated against higher standards, or specially designed precision current sources. The article describes a reference installation developed on the basis of the VNIIFTRI, where in the mode of generating ultralow currents the principle of forming a linearly increasing voltage on a reference capacitor is used. A simplified block diagram of the reference setup is shown. Issues of practical adjustment of modern electrometers are considered. The generalized results of participation in international comparisons on low currents EURAMET.EM-S44 “Comparison of ultra-low DC current sources” conducted by national metrological institutes in 2018–2020 are presented. The results of a metrological study of the calibration factor Q and an example of calculating the uncertainty budget of measurements carried out at the VNIIFTRI as part of these international comparisons are presented. The research described in the article to increase the accuracy of measurements of small and ultra-low currents of this level has valuable practical significance in the field of electrical measurements, in aeroionometry and metrology of ionizing radiation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
试验性安装用于校准电子测量仪的低电流参考源
如今,科学界对利用单电子隧道效应和现代 SI 系统定义,在单电子泵的基础上实现低电流基准源的可能性产生了浓厚的兴趣。然而,这种效应在日常计量实践中的实际应用尚未达到广泛应用的阶段。通常情况下,实验室的常规校准工作要么使用根据更高标准校准的批量生产仪器(低电流源和仪表、电度表),要么使用专门设计的精密电流源。文章介绍了在 VNIIFTRI 基础上开发的基准装置,在产生超低电流的模式下,使用了在基准电容器上形成线性增加电压的原理。参考装置的简化框图如图所示。考虑了现代验电器的实际调整问题。介绍了各国计量机构在 2018-2020 年参与低电流 EURAMET.EM-S44 "超低直流电流源比较 "国际比较的一般结果。文章介绍了校准因子 Q 的计量研究结果,以及作为这些国际比对的一部分,在 VNIIFTRI 进行的测量的不确定性预算计算实例。文章中描述的旨在提高该级别小电流和超低电流测量精度的研究在电气测量、航空电离测量和电离辐射计量领域具有宝贵的现实意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
International comparisons in the field of measurement of specific adsorption of gases and specific surface area of solids: the optimal amount to ensure calibration and measurement capabilities Experimental installation of a reference source of low currents for calibration of electrometers Development of state information systems in the field of metrology: main tasks Effect of surfactants on the degree of polydispersity of a suspension of polystyrene latex spheres Scientific equipment for the “Sun-Terahertz” space experiment: study of the temperature effect of the Golay cell
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1