Evaluation of Distribution Transformer Placement Optimal Based on Load Balance

Aris Triwiyatno, Bambang Winardi
{"title":"Evaluation of Distribution Transformer Placement Optimal Based on Load Balance","authors":"Aris Triwiyatno, Bambang Winardi","doi":"10.59890/ijgsr.v2i4.1784","DOIUrl":null,"url":null,"abstract":"The distribution system is divided into primary and secondary distribution networks. The primary distribution network is the network from the main substation transformer (GI) to the distribution substation, while the secondary is the channel network from the distribution substation transformer to the consumer or load. The primary distribution network is better known as the medium voltage network (JTM 20kV) while the secondary distribution is the low voltage network (JTR 220/380V). The distribution network is the part of the electric power system that is closest to customers or loads compared to the transmission network. Currently, network electricity conditions throughout Indonesia are experiencing a decline of 5% which is due to various factors such as the medium-scale diameter of the conductors used, so at the farthest SR the value of overvoltage is 10%, the allowable voltage drop and must anticipate an increase in electrical load of 22.7 %, the placement of the transformer is not optimal and the distance the electrical energy travels from the transformer to the load is not paid enough attention so that the capacity of a transformer is not optimal and the voltage drop is also greater. Given these conditions, re-evaluation and planning is needed that takes into account planning criteria such as allowable voltage drops and continuity of electricity services so that optimization of the network used can emerge.","PeriodicalId":516658,"journal":{"name":"International Journal of Global Sustainable Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Global Sustainable Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.59890/ijgsr.v2i4.1784","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The distribution system is divided into primary and secondary distribution networks. The primary distribution network is the network from the main substation transformer (GI) to the distribution substation, while the secondary is the channel network from the distribution substation transformer to the consumer or load. The primary distribution network is better known as the medium voltage network (JTM 20kV) while the secondary distribution is the low voltage network (JTR 220/380V). The distribution network is the part of the electric power system that is closest to customers or loads compared to the transmission network. Currently, network electricity conditions throughout Indonesia are experiencing a decline of 5% which is due to various factors such as the medium-scale diameter of the conductors used, so at the farthest SR the value of overvoltage is 10%, the allowable voltage drop and must anticipate an increase in electrical load of 22.7 %, the placement of the transformer is not optimal and the distance the electrical energy travels from the transformer to the load is not paid enough attention so that the capacity of a transformer is not optimal and the voltage drop is also greater. Given these conditions, re-evaluation and planning is needed that takes into account planning criteria such as allowable voltage drops and continuity of electricity services so that optimization of the network used can emerge.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于负载平衡的配电变压器最佳布置评估
配电系统分为一次配电网和二次配电网。一次配电网是从主变电站变压器(GI)到配电变电站的网络,而二次配电网是从配电变电站变压器到用户或负载的通道网络。一次配电网被称为中压网(JTM 20kV),而二次配电网则是低压网(JTR 220/380V)。与输电网络相比,配电网络是电力系统中最靠近用户或负载的部分。目前,印度尼西亚全国的配电网用电条件下降了 5%,这是由多种因素造成的,如使用的导线直径中等,因此在最远的 SR 处过电压值为 10%,允许的电压降为 22.7%,必须预计电力负荷的增加,变压器的位置不理想,电能从变压器到负荷的传输距离没有得到足够重视,因此变压器的容量不理想,电压降也较大。鉴于这些情况,需要重新进行评估和规划,考虑到可允许的电压降和电力服务的连续性等规划标准,从而优化所使用的网络。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation of Distribution Transformer Placement Optimal Based on Load Balance Effectiveness Of Manual Material Handling Tools For Chicken Feed Transporting Rails And Online Marketing Websites Identification of the Potential for Development of the Rainforest Lodges Kedah Ecotourism Area, Gayo Lues District, Aceh Province Contingency Leadership and Its Effects on Worker Performance in Ambon City's Ministry of Religious Affairs Management of Local Broadcast Production and Enforcement of P3SPS by Indosiar Ambon TV
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1