{"title":"Dose verifications in several organs in abdominal computed tomography (CT) scan by using Al2O3 OSL dosimeters","authors":"Mohd Fahmi Mohd Yusof, Muhammad Haiqal Ramli, Che Nazri Che Hussin, Ahmad Bazlie Abd Kadir, Norriza Mohd Isa","doi":"10.1088/1757-899x/1308/1/012012","DOIUrl":null,"url":null,"abstract":"\n The study investigated the dose of several organs in the computed tomography (CT) scan by using Al2O3 optically stimulated luminescent (OSL) dosimeters. The organs of right and left kidney, right pancreas, spleen and liver in an anthropomorphic human phantom were investigated for the dose received during the scan. The OSL dosimeters are embedded into custom-made wax and replace onto two selected slices of human body phantom where the selected organs are located. The phantom was scanned with by using adult abdomen protocol. The percentage differences of OSL doses reading compared to the previous study data and the international dose reference level (DRL). The doses obtained from OSL NanoDots® showed excellent agreement compared to XRQA film dosimeters with percentage differences within 5%. The doses measured by using OSL dosimeters in five organs were also within the range of the national DRL values by the Ministry of Health of Malaysia (MOH). These findings suggest that our results can be utilized to verify the doses received by internal organs during computed tomography abdomen protocols. The overall results indicated the suitability of OSL dosimeters for the indirect dose verification in the CT scan.","PeriodicalId":509593,"journal":{"name":"IOP Conference Series: Materials Science and Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IOP Conference Series: Materials Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1757-899x/1308/1/012012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The study investigated the dose of several organs in the computed tomography (CT) scan by using Al2O3 optically stimulated luminescent (OSL) dosimeters. The organs of right and left kidney, right pancreas, spleen and liver in an anthropomorphic human phantom were investigated for the dose received during the scan. The OSL dosimeters are embedded into custom-made wax and replace onto two selected slices of human body phantom where the selected organs are located. The phantom was scanned with by using adult abdomen protocol. The percentage differences of OSL doses reading compared to the previous study data and the international dose reference level (DRL). The doses obtained from OSL NanoDots® showed excellent agreement compared to XRQA film dosimeters with percentage differences within 5%. The doses measured by using OSL dosimeters in five organs were also within the range of the national DRL values by the Ministry of Health of Malaysia (MOH). These findings suggest that our results can be utilized to verify the doses received by internal organs during computed tomography abdomen protocols. The overall results indicated the suitability of OSL dosimeters for the indirect dose verification in the CT scan.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用 Al2O3 OSL 剂量计对腹部计算机断层扫描(CT)中多个器官的剂量进行验证
这项研究使用 Al2O3 光激发发光(OSL)剂量计对计算机断层扫描(CT)扫描中几个器官的剂量进行了研究。在一个拟人化的人体模型中,对左右肾脏、右侧胰腺、脾脏和肝脏等器官在扫描过程中接收到的剂量进行了调查。将 OSL 剂量计嵌入特制的蜡中,并将其放置在人体模型的两个选定切片上,这两个切片就是选定器官的位置。人体模型采用成人腹部方案进行扫描。将 OSL 剂量读数的百分比差异与先前的研究数据和国际剂量参考水平(DRL)进行比较。与 XRQA 薄膜剂量计相比,OSL NanoDots® 获得的剂量显示出极好的一致性,百分比差异在 5%以内。使用 OSL 剂量计测量的五个器官的剂量也在马来西亚卫生部(MOH)规定的国家 DRL 值范围内。这些结果表明,我们的研究结果可以用来验证腹部计算机断层扫描方案中内脏器官接收到的剂量。总体结果表明,OSL 剂量计适用于 CT 扫描中的间接剂量验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
CTBT data for environmental radiological monitoring: a preliminary study in Malaysia Natural weathering effects on the surface morphological and physicochemical properties of radiation curable coatings in tropical climate The potential of NAA and ICP-MS for determining soil dispersibility in relation to landslide incidents Underground utility inspection using ground penetrating radar Characterisation of sealed radioactive source for nuclear forensic purposes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1