Beata Skowrońska, Barbara Szulc, Radosław Morek, Michał Baranowski, T. Chmielewski
{"title":"Selected properties of X120Mn12 steel welded joints by means of the plasma-MAG hybrid method","authors":"Beata Skowrońska, Barbara Szulc, Radosław Morek, Michał Baranowski, T. Chmielewski","doi":"10.1177/14644207241256113","DOIUrl":null,"url":null,"abstract":"The article describes properties of welds made of high wear resistance X120Mn12 steel obtained by the hybrid PTA-MAG (plasma transferred arc – metal active gas) method. The specimens were 8 mm thick rectangular (200 mm × 350 mm) sheets metal. The analyzed butt welds were made with the parameters selected according to the criterion of smallest cross-sectional area of welds and the narrowest HAZ (heat affected zone). The outcome of metallographic tests of weld, HAZ and parent material, hardness distribution and XRD (X-ray diffraction) patterns of selected areas are presented. The IIT (Instrumented Indentation Test) method was used to describe the distribution of mechanical properties shaped by thermal cycle annealing of the welding process. The investigation shows that the application of the PTA-MAG hybrid heat source for welding manganese steel enables the use of the filler material ER307 (AWS-A5.9). The hybrid PTA-MAG welding system has the relatively high potential to be an efficient alternative to welding standard processes for X120Mn12 steel due to the HAZ overheating limitation. The zone of high-risk weld cracking is the part of the HAZ close to the fusion area that has been reheated during weldment formation. Heat input about 0.6 kJ/mm is needed to provide full deep penetration butt weld without defects and with a vapor capillary of wide enough to cover the weld gap. The increase of hardness in the welded joint is smooth distributed and going up to 10% compared to the base material. The width of HAZ was <1 mm. Intensive carbides precipitation in HAZ has been avoided successfully.","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":"36 6","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2024-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1177/14644207241256113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
The article describes properties of welds made of high wear resistance X120Mn12 steel obtained by the hybrid PTA-MAG (plasma transferred arc – metal active gas) method. The specimens were 8 mm thick rectangular (200 mm × 350 mm) sheets metal. The analyzed butt welds were made with the parameters selected according to the criterion of smallest cross-sectional area of welds and the narrowest HAZ (heat affected zone). The outcome of metallographic tests of weld, HAZ and parent material, hardness distribution and XRD (X-ray diffraction) patterns of selected areas are presented. The IIT (Instrumented Indentation Test) method was used to describe the distribution of mechanical properties shaped by thermal cycle annealing of the welding process. The investigation shows that the application of the PTA-MAG hybrid heat source for welding manganese steel enables the use of the filler material ER307 (AWS-A5.9). The hybrid PTA-MAG welding system has the relatively high potential to be an efficient alternative to welding standard processes for X120Mn12 steel due to the HAZ overheating limitation. The zone of high-risk weld cracking is the part of the HAZ close to the fusion area that has been reheated during weldment formation. Heat input about 0.6 kJ/mm is needed to provide full deep penetration butt weld without defects and with a vapor capillary of wide enough to cover the weld gap. The increase of hardness in the welded joint is smooth distributed and going up to 10% compared to the base material. The width of HAZ was <1 mm. Intensive carbides precipitation in HAZ has been avoided successfully.
期刊介绍:
ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications.
The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.