Mechanical performance of patient-specific prefabricated temporary shell versus laboratory-fabricated CAD/CAM provisional implant-supported single-tooth restorations: A laboratory study

IF 4.8 1区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Clinical Oral Implants Research Pub Date : 2024-06-05 DOI:10.1111/clr.14308
Vincent J. J. Donker, Paulien E. A. Janss, Christiaan W. P. Pol, Gerry M. Raghoebar, Arjan Vissink, Henny J. A. Meijer
{"title":"Mechanical performance of patient-specific prefabricated temporary shell versus laboratory-fabricated CAD/CAM provisional implant-supported single-tooth restorations: A laboratory study","authors":"Vincent J. J. Donker,&nbsp;Paulien E. A. Janss,&nbsp;Christiaan W. P. Pol,&nbsp;Gerry M. Raghoebar,&nbsp;Arjan Vissink,&nbsp;Henny J. A. Meijer","doi":"10.1111/clr.14308","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>To evaluate the mechanical performance of patient-specific prefabricated temporary shell versus laboratory-fabricated CAD/CAM provisional restorations on titanium temporary abutments, with and without thermo-mechanical ageing.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>Implants with a conical connection were divided into four groups (<i>n</i> = 24) and restored with temporary shell or laboratory-fabricated central or lateral incisor PMMA restorations that were relined or bonded on titanium temporary abutments. The diameter of the central and lateral incisor groups' implants was regular (<i>ϕ</i> 4.3 mm) or narrow (<i>ϕ</i> 3.5 mm), respectively. Half of each group's specimens were subjected to ageing, simultaneous thermocycling (5–55°C) and chewing simulation (120,000 cycles, 50 N, 1.7 Hz) resulting in eight groups in total (<i>n</i> = 12). The aged specimens were evaluated with optical microscopy, and survival and complication rates were determined according to modified USPHS criteria. The non-aged specimens and those that had survived ageing were loaded until failure, whereupon bending moments were calculated.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Survival rates after ageing were 100% for all groups. Apart from wear facets (<i>ϕ</i> 2–3 mm) on the palatal restoration surface, no complications were observed. The mean fracture load and bending moments ranged between 597.6–847.1 N and 433.3–550.6 Ncm, respectively, with no significant differences between the eight groups (<i>p</i> = .25; <i>p</i> = .20).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>As patient-specific temporary shell central and lateral incisor provisional implant-supported restorations are mechanically stable enough to withstand clinical bite forces, even after thermo-mechanical ageing, they may serve as an alternative to laboratory-fabricated provisional restorations.</p>\n </section>\n </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":null,"pages":null},"PeriodicalIF":4.8000,"publicationDate":"2024-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.14308","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Implants Research","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/clr.14308","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

To evaluate the mechanical performance of patient-specific prefabricated temporary shell versus laboratory-fabricated CAD/CAM provisional restorations on titanium temporary abutments, with and without thermo-mechanical ageing.

Materials and Methods

Implants with a conical connection were divided into four groups (n = 24) and restored with temporary shell or laboratory-fabricated central or lateral incisor PMMA restorations that were relined or bonded on titanium temporary abutments. The diameter of the central and lateral incisor groups' implants was regular (ϕ 4.3 mm) or narrow (ϕ 3.5 mm), respectively. Half of each group's specimens were subjected to ageing, simultaneous thermocycling (5–55°C) and chewing simulation (120,000 cycles, 50 N, 1.7 Hz) resulting in eight groups in total (n = 12). The aged specimens were evaluated with optical microscopy, and survival and complication rates were determined according to modified USPHS criteria. The non-aged specimens and those that had survived ageing were loaded until failure, whereupon bending moments were calculated.

Results

Survival rates after ageing were 100% for all groups. Apart from wear facets (ϕ 2–3 mm) on the palatal restoration surface, no complications were observed. The mean fracture load and bending moments ranged between 597.6–847.1 N and 433.3–550.6 Ncm, respectively, with no significant differences between the eight groups (p = .25; p = .20).

Conclusions

As patient-specific temporary shell central and lateral incisor provisional implant-supported restorations are mechanically stable enough to withstand clinical bite forces, even after thermo-mechanical ageing, they may serve as an alternative to laboratory-fabricated provisional restorations.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
患者专用预制临时外壳与实验室制造的 CAD/CAM 临时种植体支持单牙修复体的机械性能对比:实验室研究。
目的评估钛临时基台上患者特制的预制临时外壳与实验室制作的CAD/CAM临时修复体的机械性能,包括热机械老化和非热机械老化:将锥形连接的种植体分为四组(n = 24),使用临时外壳或实验室制作的中切牙或侧切牙 PMMA 修复体进行修复,并在钛临时基台上重新衬垫或粘结。中切牙组和侧切牙组的种植体直径分别为规则(ϕ 4.3 毫米)或狭窄(ϕ 3.5 毫米)。每组一半的试样进行老化,同时进行热循环(5-55°C)和咀嚼模拟(120,000 次,50 N,1.7 Hz),共分为八组(n = 12)。老化标本采用光学显微镜进行评估,存活率和并发症发生率根据修改后的 USPHS 标准确定。对未老化试样和老化后存活的试样进行加载直至失效,然后计算弯矩:结果:各组老化后的存活率均为 100%。除了腭修复体表面的磨损面(ϕ 2-3 mm)外,没有发现其他并发症。平均折断载荷和弯曲力矩分别为 597.6-847.1 N 和 433.3-550.6 Ncm,八组之间无明显差异(p = .25; p = .20):由于患者特制的临时中切牙和侧切牙临时种植体支持修复体具有足够的机械稳定性,即使在热机械老化后也能承受临床咬合力,因此可以作为技工室制作的临时修复体的替代物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical Oral Implants Research
Clinical Oral Implants Research 医学-工程:生物医学
CiteScore
7.70
自引率
11.60%
发文量
149
审稿时长
3 months
期刊介绍: Clinical Oral Implants Research conveys scientific progress in the field of implant dentistry and its related areas to clinicians, teachers and researchers concerned with the application of this information for the benefit of patients in need of oral implants. The journal addresses itself to clinicians, general practitioners, periodontists, oral and maxillofacial surgeons and prosthodontists, as well as to teachers, academicians and scholars involved in the education of professionals and in the scientific promotion of the field of implant dentistry.
期刊最新文献
Does an untreated peri-implant dehiscence defect affect the progression of peri-implantitis?: A preclinical in vivo experimental study. Early implant placement versus ridge preservation and delayed implant placement: Analysis of profilometric, clinician- and patient-reported outcomes from a two-centre RCT. Low-dose, standard, and high-resolution cone beam computed tomography for alveolar bone measurements related to implant planning: An ex vivo study in human specimens. Factors affecting radiographic marginal bone resorption at dental implants in function for at least 5 years: A multicenter retrospective study. A cross-sectional CBCT assessment of the relative position of one-piece titanium-zirconium mini-implants placed for mandibular overdentures using non-guided surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1