Robotic-assisted differential total knee arthroplasty with patient-specific implants: surgical techniques and preliminary results.

IF 2.3 4区 医学 Q2 ORTHOPEDICS Arthroplasty Pub Date : 2024-06-10 DOI:10.1186/s42836-024-00255-1
Hanlong Zheng, Mingxue Chen, Dejin Yang, Hongyi Shao, Yixin Zhou
{"title":"Robotic-assisted differential total knee arthroplasty with patient-specific implants: surgical techniques and preliminary results.","authors":"Hanlong Zheng, Mingxue Chen, Dejin Yang, Hongyi Shao, Yixin Zhou","doi":"10.1186/s42836-024-00255-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>In total knee arthroplasty (TKA), achieving soft-tissue balance while retaining acceptable lower limb alignment is sometimes difficult and may lead to patient dissatisfaction. Theoretically, patient-specific implants can bring great benefits, while the lack of precise surgical tools may hinder the improvement of outcomes. The objective of this study was to illustrate surgical techniques and evaluate kinematics and early clinical outcomes of robotic-assisted TKA using patient-specific implants.</p><p><strong>Methods: </strong>Based on preoperative CT scan, femoral and tibial components were 3D printed. Medial and lateral tibial liners were separate with different thicknesses, posterior slopes and conformity. TiRobot Recon Robot was used for surgery, and was armed with smart tools that quantify gap, force and femoral-tibial track. We collected data on demographics, intraoperative gap balance and femoral-tibial motion. In the follow-up, we evaluated the range of motion, Visual Analogue Scale (VAS), forgotten joint score (FJS), Knee injury and Osteoarthritis Outcome Score, Joint Replacement (KOOS, JR) score. Radiological data were also harvested.</p><p><strong>Results: </strong>Fifteen patients (17 knees) were enrolled with a mean age of 64.6 ± 6.4 (53-76) years. In 5 knees, we used symmetric tibial liners, the rest were asymmetric. After surgery, the average alignment was 1.6 ± 2.0 (-3-5) degrees varus. The average follow-up lasted 6.7 ± 4.2 (1-14) months. The mean visual analogue scale was 0.8 ± 0.7 (0-2), FJS was 62.4 ± 25.3 (0-87), KOOS was 86.5 ± 9.4 (57-97). 11 patients were \"very satisfied\", 3 were \"satisfied\" with the result, and one patient was neutral due to restricted extension and unsatisfactory rehabilitation at five months' follow-up.</p><p><strong>Conclusions: </strong>With patient-specific implants and robotics, TKA could be performed by a mathematical way, which was dubbed a \"differential\" TKA. Intraoperative kinematics was excellent in terms of gap-force balancing and femoral-tibial relative motion. Preliminary clinical outcomes were overall satisfactory.</p>","PeriodicalId":52831,"journal":{"name":"Arthroplasty","volume":"6 1","pages":"34"},"PeriodicalIF":2.3000,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11163793/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroplasty","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42836-024-00255-1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: In total knee arthroplasty (TKA), achieving soft-tissue balance while retaining acceptable lower limb alignment is sometimes difficult and may lead to patient dissatisfaction. Theoretically, patient-specific implants can bring great benefits, while the lack of precise surgical tools may hinder the improvement of outcomes. The objective of this study was to illustrate surgical techniques and evaluate kinematics and early clinical outcomes of robotic-assisted TKA using patient-specific implants.

Methods: Based on preoperative CT scan, femoral and tibial components were 3D printed. Medial and lateral tibial liners were separate with different thicknesses, posterior slopes and conformity. TiRobot Recon Robot was used for surgery, and was armed with smart tools that quantify gap, force and femoral-tibial track. We collected data on demographics, intraoperative gap balance and femoral-tibial motion. In the follow-up, we evaluated the range of motion, Visual Analogue Scale (VAS), forgotten joint score (FJS), Knee injury and Osteoarthritis Outcome Score, Joint Replacement (KOOS, JR) score. Radiological data were also harvested.

Results: Fifteen patients (17 knees) were enrolled with a mean age of 64.6 ± 6.4 (53-76) years. In 5 knees, we used symmetric tibial liners, the rest were asymmetric. After surgery, the average alignment was 1.6 ± 2.0 (-3-5) degrees varus. The average follow-up lasted 6.7 ± 4.2 (1-14) months. The mean visual analogue scale was 0.8 ± 0.7 (0-2), FJS was 62.4 ± 25.3 (0-87), KOOS was 86.5 ± 9.4 (57-97). 11 patients were "very satisfied", 3 were "satisfied" with the result, and one patient was neutral due to restricted extension and unsatisfactory rehabilitation at five months' follow-up.

Conclusions: With patient-specific implants and robotics, TKA could be performed by a mathematical way, which was dubbed a "differential" TKA. Intraoperative kinematics was excellent in terms of gap-force balancing and femoral-tibial relative motion. Preliminary clinical outcomes were overall satisfactory.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
机器人辅助差动全膝关节置换术与患者特异性植入物:手术技术与初步结果。
目的:在全膝关节置换术(TKA)中,实现软组织平衡同时保持可接受的下肢对齐有时很困难,并可能导致患者不满意。从理论上讲,为患者量身定制的植入物可以带来巨大的益处,但缺乏精确的手术工具可能会阻碍手术效果的改善。本研究旨在说明手术技巧,并评估使用患者特异性植入物的机器人辅助 TKA 的运动学和早期临床效果:根据术前CT扫描,3D打印股骨和胫骨组件。方法:根据术前 CT 扫描结果,对股骨和胫骨组件进行三维打印,胫骨内侧和外侧衬垫分别采用不同的厚度、后斜度和保形性。手术使用了 TiRobot Recon 机器人,该机器人配备了智能工具,可量化间隙、力和股骨-胫骨轨迹。我们收集了有关人口统计学、术中间隙平衡和股骨胫骨运动的数据。在随访中,我们评估了活动范围、视觉模拟量表(VAS)、遗忘关节评分(FJS)、膝关节损伤和骨关节炎结果评分、关节置换(KOOS,JR)评分。此外,还采集了放射学数据:15名患者(17个膝关节)的平均年龄为64.6 ± 6.4 (53-76)岁。在 5 个膝关节中,我们使用了对称的胫骨内衬,其他膝关节则使用了不对称的胫骨内衬。术后,平均对位为 1.6 ± 2.0 (-3-5) 度外翻。平均随访时间为 6.7 ± 4.2(1-14)个月。平均视觉模拟量表为 0.8 ± 0.7 (0-2),FJS 为 62.4 ± 25.3 (0-87),KOOS 为 86.5 ± 9.4 (57-97)。11名患者对治疗效果表示 "非常满意",3名患者表示 "满意",1名患者对治疗效果持中立态度,原因是在5个月的随访中,患者的外展受到限制,康复效果不理想:结论:利用患者特异性植入物和机器人技术,TKA可以通过数学方法进行,这种方法被称为 "差分 "TKA。术中运动学在间隙-力平衡和股骨-胫骨相对运动方面表现出色。初步临床结果总体令人满意。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Arthroplasty
Arthroplasty ORTHOPEDICS-
CiteScore
2.20
自引率
0.00%
发文量
49
审稿时长
15 weeks
期刊最新文献
Conference Proceedings for the 10th Annual Meeting of Arthroplasty Society in Asia (ASIA), 26th Annual Meeting of the Thai Hip and Knee Society (THKS), and the 16th Annual Meeting of the ASEAN Arthroplasty Association (AAA). DAIR for periprosthetic joint infections-One week to save the joint? The distribution of Coronal Plane Alignment of the Knee (CPAK) phenotypes in the Malaysian population and their correlation with demographic variables. What is the clinical utility of acoustic and vibrational analyses in uncemented total hip arthroplasty? Nanoparticle ultrasonication: a promising approach for reducing bacterial biofilm in total joint infection-an in vivo rat model investigation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1