Olga M Wroblewski, Christopher S Kennedy, Emmanuel E Vega-Soto, Celeste E Forester, Eileen Y Su, Matthew H Nguyen, Paul S Cederna, Lisa M Larkin
{"title":"Impact of Passaging Primary Skeletal Muscle Cell Isolates on the Engineering of Skeletal Muscle.","authors":"Olga M Wroblewski, Christopher S Kennedy, Emmanuel E Vega-Soto, Celeste E Forester, Eileen Y Su, Matthew H Nguyen, Paul S Cederna, Lisa M Larkin","doi":"10.1089/ten.TEA.2024.0044","DOIUrl":null,"url":null,"abstract":"<p><p>Volumetric muscle loss (VML) is a clinical state that results in impaired skeletal muscle function. Engineered skeletal muscle can serve as a treatment for VML. Currently, large biopsies are required to achieve the cells necessary for the fabrication of engineered muscle, leading to donor-site morbidity. Amplification of cell numbers using cell passaging may increase the usefulness of a single muscle biopsy for engineering muscle tissue. In this study, we evaluated the impact of passaging cells obtained from donor muscle tissue by analyzing characteristics of <i>in vitro</i> cellular growth and tissue-engineered skeletal muscle unit (SMU) structure and function. Human skeletal muscle cell isolates from three separate donors (P0-Control) were compared with cells passaged once (P1), twice (P2), or three times (P3) by monitoring SMU force production and determining muscle content and structure using immunohistochemistry. Data indicated that passaging decreased the number of satellite cells and increased the population doubling time. P1 SMUs had slightly greater contractile force and P2 SMUs showed statistically significant greater force production compared with P0 SMUs with no change in SMU muscle content. In conclusion, human skeletal muscle cells can be passaged twice without negatively impacting SMU muscle content or contractile function, providing the opportunity to potentially create larger SMUs from smaller biopsies, thereby producing clinically relevant sized grafts to aid in VML repair.</p>","PeriodicalId":56375,"journal":{"name":"Tissue Engineering Part A","volume":null,"pages":null},"PeriodicalIF":3.5000,"publicationDate":"2024-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tissue Engineering Part A","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/ten.TEA.2024.0044","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CELL & TISSUE ENGINEERING","Score":null,"Total":0}
引用次数: 0
Abstract
Volumetric muscle loss (VML) is a clinical state that results in impaired skeletal muscle function. Engineered skeletal muscle can serve as a treatment for VML. Currently, large biopsies are required to achieve the cells necessary for the fabrication of engineered muscle, leading to donor-site morbidity. Amplification of cell numbers using cell passaging may increase the usefulness of a single muscle biopsy for engineering muscle tissue. In this study, we evaluated the impact of passaging cells obtained from donor muscle tissue by analyzing characteristics of in vitro cellular growth and tissue-engineered skeletal muscle unit (SMU) structure and function. Human skeletal muscle cell isolates from three separate donors (P0-Control) were compared with cells passaged once (P1), twice (P2), or three times (P3) by monitoring SMU force production and determining muscle content and structure using immunohistochemistry. Data indicated that passaging decreased the number of satellite cells and increased the population doubling time. P1 SMUs had slightly greater contractile force and P2 SMUs showed statistically significant greater force production compared with P0 SMUs with no change in SMU muscle content. In conclusion, human skeletal muscle cells can be passaged twice without negatively impacting SMU muscle content or contractile function, providing the opportunity to potentially create larger SMUs from smaller biopsies, thereby producing clinically relevant sized grafts to aid in VML repair.
期刊介绍:
Tissue Engineering is the preeminent, biomedical journal advancing the field with cutting-edge research and applications that repair or regenerate portions or whole tissues. This multidisciplinary journal brings together the principles of engineering and life sciences in the creation of artificial tissues and regenerative medicine. Tissue Engineering is divided into three parts, providing a central forum for groundbreaking scientific research and developments of clinical applications from leading experts in the field that will enable the functional replacement of tissues.